Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Determination physical method

Oscarson J L and Izatt R M 1992 Calorimetry Physical Methods of Chemistry Determination of Thermodynamic Properties 2nd edn, vol VI, ed B W Rossiter and R C Baetzold (New York Wiley)... [Pg.1919]

Molecular Weight Determinations by Physical Methods. Vapour Density. Victor Meyer s Method. [Pg.425]

Separations based upon differences in the physical properties of the components. When procedures (1) or (2) are unsatisfactory for the separation of a mixture of organic compounds, purely physical methods may be employed. Thus a mixture of volatile liquids may be fractionally distilled (compare Sections 11,15 and 11,17) the degree of separation may be determined by the range of boiling points and/or the refractive indices and densities of the different fractions that are collected. A mixture of non-volatile sohds may frequently be separated by making use of the differences in solubilities in inert solvents the separation is usually controlled by m.p. determinations. Sometimes one of the components of the mixture is volatile and can be separated by sublimation (see Section 11,45). [Pg.1092]

Braude and Nachod, Determination of Organic Structures by Physical Methods, 1955 (Academic Press). [Pg.1150]

In Chapter 2, a brief discussion of statistical mechanics was presented. Statistical mechanics provides, in theory, a means for determining physical properties that are associated with not one molecule at one geometry, but rather, a macroscopic sample of the bulk liquid, solid, and so on. This is the net result of the properties of many molecules in many conformations, energy states, and the like. In practice, the difficult part of this process is not the statistical mechanics, but obtaining all the information about possible energy levels, conformations, and so on. Molecular dynamics (MD) and Monte Carlo (MC) simulations are two methods for obtaining this information... [Pg.60]

The copolymer composition equation relates the r s to either the ratio [Eq. (7.15)] or the mole fraction [Eq. (7.18)] of the monomers in the feedstock and repeat units in the copolymer. To use this equation to evaluate rj and V2, the composition of a copolymer resulting from a feedstock of known composition must be measured. The composition of the feedstock itself must be known also, but we assume this poses no problems. The copolymer specimen must be obtained by proper sampling procedures, and purified of extraneous materials. Remember that monomers, initiators, and possibly solvents are involved in these reactions also, even though we have been focusing attention on the copolymer alone. The proportions of the two kinds of repeat unit in the copolymer is then determined by either chemical or physical methods. Elemental analysis has been the chemical method most widely used, although analysis for functional groups is also employed. [Pg.457]

The preferred quantitative deterrnination of traces of acetylene is gas chromatography, which permits an accurate analysis of quantities much less than 1 ppm. This procedure has been highly developed for air poUution studies (88) (see Airpollution control methods). Other physical methods, such as infrared and mass spectroscopy, have been widely used to determine acetylene in various mixtures. [Pg.377]

The melting points, optical rotations, and uv spectral data for selected prostanoids are provided in Table 1. Additional physical properties for the primary PGs have been summarized in the Hterature and the physical methods have been reviewed (47). The molecular conformations of PGE2 and PGA have been determined in the soHd state by x-ray diffraction, and special H and nuclear magnetic resonance (nmr) spectral studies of several PGs have been reported (11,48—53). Mass spectral data have also been compiled (54) (see Mass spectrometry Spectroscopy). [Pg.153]

Fiber friction can be deterrnined by physical methods. For rapid evaluation of fiber or yam friction, the capstan method is used, where a yam or fiber is pulled over a cylindrical surface. The frictional coefficient, ]1, can be determined according to the formula... [Pg.454]

Whilst solving some ecological problems of metals micro quantity determination in food products and water physicochemical and physical methods of analysis are employed. Standard mixture models (CO) are necessary for their implementation. The most interesting COs are the ones suitable for graduation and accuracy control in several analysis methods. Therefore the formation of poly functional COs is one of the most contemporary problems of modern analytical chemistry. The organic metal complexes are the most prospective class of CO-based initial substances where P-diketonates are the most appealing. [Pg.405]

For more detailed discussion of dipole moments, see L. E. Sutton, in Determination of Organic Structures by Physical Methods, Vbl. 1, E. A. Braude and F. C. Nachod, eds., Academic Press, New York, 1955, Chapter 9 V I. Minkin, O. A. Osipov, and Y. A. Zhdanov, Dipole Moments in Organic Chemistry, Plenum Press, New York, 1970. [Pg.16]

Charcoal Tubes Reference has been made earlier to adsorption, which is the property of some solid materials, such as activated charcoal, to physically retain solvent vapors on their surfaces. In environmental health testing, the adsorbed vapors are removed, generally with a solvent, in a laboratory. The solvent is then analyzed by physical methods (gas chromatography, etc.) to determine the individual compounds whose vapors, such as benzene, were present in the sampled air. Industrial atmospheric samples can be collected in small glass tubes (4 mm ID) packed with two sections of activated charcoal, separated and retained with fiberglass plugs. To obtain an air sample, the sealed ends of the tube are broken off, and air is drawn through the charcoal at the rate of 1 liter per minute by means... [Pg.276]

Boden, N. In Determination of Organic Structures by Physical Methods Nachod, F.C. Zuck-erman, J.J., Ed. Academic Press New York, 1971 Vol. 4, Chapter 2. [Pg.184]

In general, physical methods have been used to study tautomerism more successfully than chemical methods, and, of the physical methods, those involving measurements of basicities and ultraviolet spectra are the most important, followed by those involving measurement of infrared and proton resonance spectra. An attempt is made here to delineate the scope and to indicate the advantages and disadvantages of the various methods. A short review by Mason of the application of spectroscopic methods appeared in 1955. Recently a set of reviews on the applications of physical methods to heterocyclic chemistry has appeared, which treats incidentally the determination of tautomeric structure. [Pg.325]

Determination of Binding and Rate Constants by Nontransport Physical Methods... [Pg.191]

J. B. Ott and J. Rex Goates, "Temperature Measurement with Applications to Phase Equilibria Studies," in Physical Methods of Chemistry, Vol. VI. Determination of Thermodynamic Properties B. W. Rossiter and R. C. Baetzold, eds, John Wiley Sons, New York, 1992, pp. 463-471. [Pg.36]

Other physical methods were also applied to the elucidation of the isomerism of diazocyanides, e. g., determination of diamagnetic susceptibility, the Faraday effect (optical rotation in a magnetic field), and electronic and infrared spectra. Hantzsch and Schulze measured ultraviolet spectra at a remarkably early date (1895 a). Unfortunately, their results and later work (Le Fevre and Wilson, 1949 Freeman and Le Fevre, 1950) did not allow unambiguous conclusions, except perhaps the observation that the molar extinction coefficients of the band at lowest frequency are consistently larger in all types of (i -compounds Ar — N2 - X than in the corresponding (Z)-iso-mers (Zollinger, 1961, p. 62). [Pg.146]

Physical methods for endpoint detection have been suggested. Hellsten [226] proposed an instrumental turbidimetric method to determine the endpoint, which does not need indicators. Since chloroform is emulsified by the anionic surfactant, changes in the optical density can be followed by a colorimeter thus detecting the endpoint when the emulsion breaks. Another turbidimetric method based on commercially available automatic titrators has also been proposed [227],... [Pg.280]

Other detection methods are based on optical transmittance [228-231], Alcohol sulfates have been determined by spectrophotometric titration with barium chloride in aqueous acetone at pH 3 and an indicator [232] or by titration with Septonex (carbethoxypentadecyltrimethylammonium bromide) and neutral red as indicator at pH 8.2-8.4 and 540 nm [233]. In a modified two-phase back-titration method, the anionic surfactant solution is treated with hyamine solution, methylene blue, and chloroform and then titrated with standard sodium dodecyl sulfate. The chloroform passing through a porous PTFE membrane is circulated through a spectrometer and the surfactant is analyzed by determining the absorbance at 655 nm [234]. The use of a stirred titration vessel combined with spectrophotometric measurement has also been suggested [235]. Alternative endpoint detections are based on physical methods, such as stalag-mometry [236] and nonfaradaic potentiometry [237]. [Pg.280]

Microscopy is one of the most direct physical methods for determining surface roughness. The resolution can go from macroscopic to atomic size, depending on the technique. Thus the order of magnitude of the range of observation is the millimeter for optical microscopy, the micrometer for... [Pg.42]

The Characterization and Properties of Small Metal Particles. Y. Takasu and A. M. Bradshaw, Surf. Defect. Prop. Solids p. 401 1978). 2. Cluster Model Theory. R. P. Messmer, in "The Nature of the Chemisorption Bond G. Ertl and T. Rhodin, eds. North-Holland Publ., Amsterdam, 1978. 3. Clusters and Surfaces. E. L. Muetterties, T. N. Rhodin, E. Band, C. F. Brucker, and W. R. Pretzer, Cornell National Science Center, Ithaca, New York, 1978. 4. Determination of the Properties of Single Atom and Multiple Atom Clusters. J. F. Hamilton, in "Chemical Experimentation Under Extreme Conditions (B. W. Rossiter, ed.) (Series, "Physical Methods of Organic Chemistry ), Wiley (Interscience), New York (1978). [Pg.130]

From Brundle, C.R. Robin, M.B., in Nachod Zuckerman Determination of Organic Structures by Physical Methods, Vol. 3 Academic Press NY, 1971, p. 18. [Pg.26]


See other pages where Determination physical method is mentioned: [Pg.40]    [Pg.40]    [Pg.218]    [Pg.1904]    [Pg.513]    [Pg.458]    [Pg.487]    [Pg.4]    [Pg.373]    [Pg.734]    [Pg.209]    [Pg.46]    [Pg.226]    [Pg.288]    [Pg.139]    [Pg.176]    [Pg.189]    [Pg.302]    [Pg.162]    [Pg.111]    [Pg.116]    [Pg.117]    [Pg.117]    [Pg.1230]    [Pg.30]    [Pg.205]    [Pg.264]   
See also in sourсe #XX -- [ Pg.294 ]




SEARCH



Physical methods

© 2024 chempedia.info