Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Decreased matrix

Guevremont et al. [117] studied the use of various matrix modifiers in the graphite furnace gas method of determination of cadmium in seawater. These included citric acid, lactic acid, aspartic acid, histidine, and EDTA. The addition of less than 1 mg of any of the compounds to 1 ml seawater significantly decreased matrix interference. Citric acid achieved the highest sensitivity and reduction of interference, with a detection limit of 0.01 pg cadmium per litre. [Pg.148]

Antithrombotic effects Decreased matrix metalloproteinases Increased tissue inhibitor of metalloproteinase 1 Increased collagen and fewer inflammatory cells in atherosclerotic plaque Reduced tissue factor expression and thrombin generation... [Pg.163]

Figure 7 Decreased Matrix and Corresponding Matrix of structures 1 and 2 with original order (starting atom pair 2-7) [1]. The information shown belongs to one partial mapping between structures 1 and 2, before any backtracking operation is performed and with the common substructures found drawn in bold lines. [From the American Chemical Society (the bold highlighting added and all signs removed.)]... Figure 7 Decreased Matrix and Corresponding Matrix of structures 1 and 2 with original order (starting atom pair 2-7) [1]. The information shown belongs to one partial mapping between structures 1 and 2, before any backtracking operation is performed and with the common substructures found drawn in bold lines. [From the American Chemical Society (the bold highlighting added and all signs removed.)]...
H7. Huang, Y., Haraguchi, M., Lawrence, D. A., Border, W. A., u, L., and Noble, N. A., A mutant, noninhibitory plasminogen activator inhibitor type 1 decreases matrix accumulation in experimental glomerulonephritis. J. Clin. Invest. 112, 379-388 (2003). [Pg.128]

The role of the supporting electrolyte is, however, more complex. It decreases the cell resistance, strongly influences the double-layer structure - at high concentration of supporting electrolyte the charging and faradaic processes can be separated, which allows simplification of the modeling of the cell impedance and the mathematical treatment - and, in analytical applications, may decrease matrix effects. [Pg.44]

Matrix interference is high and relates to the matrix composition and the metallurgical structure of the sample. Therefore, a wide range of standard samples and matrix coinection procedures are used (Section 21.5.2.1). Better. selection of the analytical zone of the spark is now possible with the aid of optical fibers and may decrease matrix interference. [Pg.693]

The effect of the molecular weight of NR (NO, N1 and N2) on the phase-specific CB localization in the SBR/NR blend is shown in Figure 6.15(b). In the first mixing process, the NR phase with lower viscosity can wet CB faster than that with higher viscosity. This behaviour is in agreement with Equation (6.34), which shows that the wetting speed b increases with decreasing matrix viscosity. In the subsequent period, the viscosity seems not to affect the CB relocalization. [Pg.179]

Recorded kinetic energy distributions of secondary ions (secondary ion intensity versus emission energy) display a peak at around 2-5 eV emission energy whereupon they drop in intensity. Molecular ion intensities decrease more rapidly than those for atomic secondary ions. Indeed, the latter can extend out to several hundred eV. Decreased matrix effects are also noted for the higher emission energy secondary ions. [Pg.140]

In addition, drug-polymer interaction led to neutralization of the carboxyl groups of the ionic polymer and suppression of the electrostatic repulsion between its anionic groups, which reduced the uncoiling of the polymer and chain relaxation, which lead to a decreased matrix swelling [146]. [Pg.36]

Physical and thermal parameters improved sharply after such a modification due to decreased matrix material in the fuel elements and increased flow cross section. Six element channels were gradually replaced by five element channels during refueling of the operating reactor. The removal of one of the elements allowed for an increase in steam velocity in the upward flowing fuel elements (Samoylov et ah, 1976). Stainless steel was used as the outer sheath material. Uranium dioxide dispersed in matrix alloy was used as fuel elements in SHS channels. Improvements in the performance of various BNPP parameters are listed in Tables A5.5 and A5.6. [Pg.839]

Both DSC and polarized light microscopy analyses have confirmed several literature reports that caibon nanotubes are effective nucleating agents in a polymer matrix. However, there is an optimum value of around 2 wt% CNTs above which the effectiveness of CNTs to increase the ciystallinity of the matrix polymer diminishes, either as a result of decreased matrix material or increased agglomeration of the nanofillers. [Pg.2258]


See other pages where Decreased matrix is mentioned: [Pg.480]    [Pg.257]    [Pg.113]    [Pg.81]    [Pg.83]    [Pg.449]    [Pg.504]    [Pg.92]    [Pg.1501]    [Pg.2690]    [Pg.1499]    [Pg.113]    [Pg.690]    [Pg.354]   
See also in sourсe #XX -- [ Pg.504 , Pg.505 ]




SEARCH



Decrease

Decreasing

© 2024 chempedia.info