Deconvolution software

Figure 15 shows this same expanded region when di-methyl terephthalate is used as the monomer. The only difference is the sharp single peak labelled g, which arises from residual methyl ester end groups. This resonance sits on top of the triplet arising from the -CH2OH (f) end (at 400 MHz) and, therefore, deconvolution software is used to measure these residual methyl ester ends. [Pg.189]

The analysis of cell-cycle progression was one of the earliest applications of flow cytometry (for review, see Darzynkiewicz et al., 2004). In this assay, fluorescence signals from cells stained with DNA-binding fluorochromes are plotted as DNA content histograms that may be analyzed by using histogram deconvolution software to quantify cell-cycle phase distributions (Rabinovitch 1994). Fluorochromes that are useful for this purpose are the plasma membrane-impermeant DNA stains, propidium iodide (PI),... [Pg.312]

Analyze the data (as in O Figure 13-7) by using DNA content frequency histogram deconvolution software, such as ModFit LT (Verity Software, Inc., Topsham, ME). [Pg.319]

Each thermogram was normalized on scan rate, the corresponding (scan-rate-normalized) buffer-buffer baseline was subtracted, and the differential heat capacity values were divided by the number of moles of protein or peptide in the sample, to yield ordinate values in terms of calories moF deg. The resulting files were then analyzed using the deconvolution software. [Pg.316]

When conventional methods of manual optimisation are no longer sufficient, it is possible to use deconvolution software or fuzzy logic to deconvolute unresolved peaks into Gaussian components for which the area can be easily measured (see Fig. 1.12). [Pg.20]

It is seen that two Gaussian shaped peaks can be easily extracted from the composite envelope and the software could also supply values for either the heights of the deconvoluted peaks or their area. It should be noted, however, that the two peaks are clearly discernible and the deconvoluting software can easily identify the approximate positions... [Pg.477]

Deconvoluting software has limited application and must be used with considerable caution. Every effort should be made to separate all the components of a mixture by chromatography and peak deconvolution should be employed only as a last resort. [Pg.480]

LC ESI (8) mass spectra were recorded on a Finnigan TSQ700 instrument (San Jose, CA) in positive ion mode. A sample aliquot was injected into a fused silica microcapillary column with an inside diameter of 100 pm. The microcapillary was filled at the end with 10 cm of a C-18 reversed phase resin. PMP labeled oligosaccharides were eluted at ca. 1 pL/min directly into the electrospray ionization source with a 10 min gradient of acetic acid in H2O (0.5 %, v/v) to 80 % acetonitrile. Determination of experimental molecular weights was done with the deconvolution software provided by the manufacturer. [Pg.323]

GC xGC-ToF MS linearity was excellent in solvent and only slightly affected by the matrix, and the LODs were in general below 20 gg/kg. Furthermore, the acquisition of full-range mass spectra provided powerful confirmation of the pesticides in the sample, even for nontarget analytes [45,48,49]. This potential is in principle reinforced by the automated peak find and spectral deconvolution software capabilities, although in practice intensive manual data revision is often needed [45,48,50]. [Pg.272]

One problem arises in DAD use that was not as major in single-wavelength detection, the absorbance of the mobile phase. In single-wavelength detection under isocratic (constant composition) conditions, any absorbance due to the mobile-phase solvents only resulted in a constant increase in the baseline. This was easily overcome by normalizing the basehne output to zero. If gradient elution was used, the baseline rose in a continuous, readily accounted for fashion. With DADs, the total absorbance of the mobile-phase interferes with spectral collection in that range. Deconvolution software, however, can extract the spectra. [Pg.988]

In addition, even if peak area measurements are used, a separation of 4a will usually provide adequate accuracy and this is particularly so if computer data acquisition and processing is used with peak deconvolution software. In general, a resolution of 4a will be assumed whenever dealing with resolution or column design. In most column optimization procedures the effect of increasing the criteria for resolution can easily be accommodated if so desired. [Pg.193]

XPS measurements were carried out on an AXIS NOVA photoelectron spectrometer (Kratos Analytical, Manchester, UK). The surface atomic concentration was determined firom peak areas using sensitivity factors. Spectrum background was subtracted according to Shirley. The XPS peaks of the Ti species were analyzed by spectra deconvolution software (CasaXPS-Vision 2, Kratos Analytical, UK). [Pg.228]

Deconvolution softwares allow much lower injection rates—5 ml/s as reported above—compared to other softwares that use different approaches, such as the maximal slope model (Wintermark et ab 2001a). These lower injection rates are more practical and tolerable for patients. They do not impair accuracy, since the deconvolution analysis controls for bolus dispersion by comparing the arterial input time-attenuation curve with that of the tissue (Wintermark et al. 2001a). [Pg.113]

The huge amount of data generated by HRMS analyzers makes necessary the development of appropriate deconvolution software and accurate mass spectra libraries to improve identification of target and imtargeted compoimds. [Pg.468]

Keywords Data mining Deconvolution software Degradation products Emerging contaminants High resolution mass spectrometry system Hybrid mass spectrometry system Metabolites Non-target analysis Screening analysis Transformation products Surface water UHPLC Unknown compounds... [Pg.124]

Might obviate the need for GCXGC separations with accurate mass determinations deconvolution software can aid in identification of multiple components under peaks sensitivity intermediate between multiple reaction monitoring and product ion scan of a QQQ dynamic range = 10, mass/charge range = 10, resolution (at m/z = 1000) 10 to 10. ... [Pg.1435]


See other pages where Deconvolution software is mentioned: [Pg.184]    [Pg.440]    [Pg.562]    [Pg.210]    [Pg.210]    [Pg.212]    [Pg.324]    [Pg.569]    [Pg.171]    [Pg.188]    [Pg.286]    [Pg.20]    [Pg.176]    [Pg.606]    [Pg.78]    [Pg.366]    [Pg.756]    [Pg.97]    [Pg.109]    [Pg.501]    [Pg.201]    [Pg.109]    [Pg.230]    [Pg.131]    [Pg.559]    [Pg.156]    [Pg.247]    [Pg.331]    [Pg.322]    [Pg.17]    [Pg.124]    [Pg.140]   