Continuous-flow mode

Continuous-flow mode The mode of air supply in which a regulated amount of air is supplied to the face-piece at all timt s. [Pg.1424]

Regardless of the location of the protein and its state, cell separation needs to be inemensive, simple, and reliable, as large amounts of fermentation-broth dilute in the desired product may be handled. The objectives are to obtain a well-clarified supernatant and solids of maximum dryness, avoiding contamination by using a contained operation. Centrifugation or crossflow filtration is t ically used for cell separation, and both unit operations can be run in a continuous-flow mode [Datar and Rosen, in Stephanopoulos (ed.), op. cit., pp. 369-503]. In recent years, e3q>anded-bea adsorption has become an alternative. It combines broth clarification and adsorption separation in a single step. [Pg.73]

The on-line coupling of HPLC and NMR can either be performed in the stopped-flow or in the continuous-flow mode (Krucker et al. 2004, Grynbaum et al. 2005, Putzbach et al. 2005, Albert et al. 2006, Hentschel et al. 2006, Rehbein et al. 2007). Current sensitivity levels are in the lower nanogram range for ID II NMR spectra and in the microgram range for 2D spectra. [Pg.64]

Performing a systematic comparison of lipase-catalyzed kinetic resolutions of several seeondaiy aleohols in continuous flow mode (Figure 7) and shake flask batch mode using immobilized and non-mobilized lipases was reported by Csajagi and eo-workers [25]. The results indieated that immobilized as well as lyophilized powder forms of liphases can be effeetively used in eontinuous flow mode kinetie resolutions of raeemic alcohols in non-aqueous solvent systems. The produetivity of the lipases was higher in continuous flow reactors than in batch mode systems, whereas the enantiomer selectivities were similar. [Pg.402]

Figure 8. Deprotection under continuous flow mode [27],... Figure 8. Deprotection under continuous flow mode [27],...
The evaluation sited a number of factors that could affect process costs for groundwater treatment, including flow rate, type and concentration of contaminants, groundwater chemistry, physical site conditions, site location, availability of utilities, and treatment goals. Assumptions made for the cost estimate include any suspended solids are removed prior to CPFM treatment, the influent has an optimum pH of 8 to 9, and the ambient temperature of the influent is between 20 and 35°C. It was assumed that the system would be operational on an automated, continuous-flow mode, 7 days per week, 24 hours per day. This would lead to approximately 52.4 million gallons of water being treated in a 1-year period (D10957J, p. 22). [Pg.590]

The coupling of HPLC with NMR represents a powerful method for the high-throughput screening of peptides in mixtures run in stop-flow and continuous-flow modes. It is possible to obtain routine high-quality HPLC/NMR ID NMR data with as little as 5 pg of compound in a chromatogram peak. However, the HPLC/NMR technique cannot be favorably compared to mass spectrometry techniques (HPLC/MS) in terms of sensitivity and speed of analysis. To date, the majority of reports of the use of HPLC/NMR have been for drug metabolites.1 ... [Pg.676]

Reactors can be operated either in a batch or continuous-flow mode. The combination, batch with respect to the liquid and continuous-flow with respect to the gas, is called semibatch. Often this fine distinction is ignored and it is commonly referred to as batch. The majority of ozonation experiments reported in the literature have been performed in one-stage semi-batch heterogeneous systems, with liquid phase reactor volumes in the range VL = 1-10 L. Most full-scale applications are operated in continuous-flow for both phases. [Pg.66]

Sometimes batch and continuous flow modes can be used together in two stage processes, each stage can be operated differently. This is easy to carry out for two stage processes operated sequentially using storage tanks. Combinations of flow modes for processes with an integrated recycle are less easy, but modifications are possible. [Pg.167]

The analytical parameters with respect to H202 amperometric measurement were evaluated in both batch and continuous flow mode and their stability, especially at basic pHs, was studied. [Pg.563]

In continuous flow mode, the stability experiments were carried out for a total period of 48 and 100 h. Two different solutions (0.1 and 0.2 mmol l-1) of hydrogen peroxide were continuously passed in the wall-jet cell and the signal was first recorded for a total of 48 h. A decrease of around 10% and 15%, respectively, was detected at the end of 48 h of monitoring for 0.1 and 0.2 mM. Under these conditions (presence of hydrogen peroxide and an applied potential), PB is forced to continuously change its oxidative state according to the following equation (Eq. (24.1)) [28] ... [Pg.567]

Operational amperometric pH stability % of residual activity of PB-modified screen-printed electrode in continuous flow mode at different conditions... [Pg.568]

Fig. 24.2. Operational stability of hydrogen peroxide sensors (PB-modified sensors). Applied potential —50mV vs. int. ref. Continuous monitoring of current in continuous flow mode (10 pi min-1). Arrows indicate where solution of hydrogen peroxide was renewed, (a) Two sensors tested with 10-4 and 2 x 10-4moll-1 of hydrogen peroxide, (b) Six months old sensor tested with a solution of 2 x 10-4moll-1 of hydrogen peroxide. Reprinted from Ref. [59] with permission from Elsevier. Fig. 24.2. Operational stability of hydrogen peroxide sensors (PB-modified sensors). Applied potential —50mV vs. int. ref. Continuous monitoring of current in continuous flow mode (10 pi min-1). Arrows indicate where solution of hydrogen peroxide was renewed, (a) Two sensors tested with 10-4 and 2 x 10-4moll-1 of hydrogen peroxide, (b) Six months old sensor tested with a solution of 2 x 10-4moll-1 of hydrogen peroxide. Reprinted from Ref. [59] with permission from Elsevier.
Fig. 24.4. Study of the biosensor stability with biological sample. Arrows indicate where (i.e. biological sample) a solution obtained by dialysing a human serum with the microdialysis probe was flowed in the biosensor cell. At the beginning a perfusion solution and control solution (glucose 5 mmol l-1) were used instead of the serum to test the biosensor response. Control solution of glucose was also used during and at the end of the experiment to evaluate the stability of the biosensor. Continuous flow mode 10 pi min-1). Applied potential —50 mV vs. int. ref. Reprinted from Ref. [59] with permission from Elsevier. Fig. 24.4. Study of the biosensor stability with biological sample. Arrows indicate where (i.e. biological sample) a solution obtained by dialysing a human serum with the microdialysis probe was flowed in the biosensor cell. At the beginning a perfusion solution and control solution (glucose 5 mmol l-1) were used instead of the serum to test the biosensor response. Control solution of glucose was also used during and at the end of the experiment to evaluate the stability of the biosensor. Continuous flow mode 10 pi min-1). Applied potential —50 mV vs. int. ref. Reprinted from Ref. [59] with permission from Elsevier.
In the conventional measuring mode the sample stays in the NMR tube, and thus in the radiofrequency Helmholtz coil all of the time. In the continuous-flow mode it resides within the NMR detection coil only for a distinct time of some few seconds (Figure 1.2). This residence time t is dependent upon the volume of the detection cell and the employed flow rate (Table 1.1). For example, a detection volume of 120 jjlI, together with a flow rate of 0.5ml/min, results in a residence time of 14.4 s, while with a detection volume of 8 jjlI the residence time is only 0.96 s. A shorter residence time t within the NMR measuring coil results in a reduction of the effective lifetime of... [Pg.2]

All three suppression techniques can be used either for stopped-flow or continuous-flow acquisition. Presaturation works quite well in the stopped-flow mode, whereas the WET sequence seems to be superior in the continuous-flow mode. [Pg.18]

This example demonstrates that high-quality 13C NMR spectra can be obtained in the continuous-flow mode. Thus, it is possible to monitor electrochemical reactions of high-concentration compounds (0.1 M solutions) [3], or even to use diluted samples with 13C-labelled positions [4-6],... [Pg.250]

It also evident from the FTIR spectra that a certain degree of pre-mixing, due to diffusion in the continuous-flow mode, occurred, leading to a correspondingly large pre-reaction [110]. [Pg.82]

FIGURE 10.22 Electropherograms of the products following on-chip tryptic digestion of bovine insulin B-chain at 37°C. The flow in the reaction channel was stopped for different times to study the effect on the reaction. Control runs (see the flat curves) without insulin B-chain were performed in the continuous flow mode and in a flow with a stop time of 6 min. The arrows indicate the migration time of benzylamine, which was added as an EOF marker. All electropherograms are plotted on the same scale with an offset for clarity [1058]. Reprinted with permission from Elsevier Science. [Pg.362]


See other pages where Continuous-flow mode is mentioned: [Pg.387]    [Pg.681]    [Pg.957]    [Pg.555]    [Pg.567]    [Pg.567]    [Pg.247]    [Pg.107]    [Pg.41]    [Pg.255]    [Pg.40]    [Pg.161]    [Pg.395]    [Pg.465]    [Pg.167]    [Pg.292]    [Pg.183]    [Pg.363]    [Pg.142]    [Pg.169]    [Pg.151]    [Pg.123]    [Pg.566]    [Pg.566]    [Pg.579]    [Pg.69]    [Pg.91]    [Pg.126]    [Pg.39]    [Pg.51]   