Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Compliance support

The effect of frequency ratio v = v/w and dimensionless compliance support (k, c ) on reduced dynamic coefficients are now examined. Fig. 2 through 4 show the dimensionless reduced coefficients plotted versus the dimensionless support stiffness k for various values of pad mass m, support damping c and frequency ratio... [Pg.160]

A linear analysis to determine the reduced dynamic coefficients of a tilting pad thrust bearing has been presented. This one is then used to study the effects of frequency, pad mass and compliance support on reduced dynamic coefficients. The eight pads thrust bearing have been examined. The results shown ... [Pg.160]

All directors and facility managers must be accountable for safety compliance, support safety efforts for their operations, and regularly reinforce the importance of safety compliance to their employees. [Pg.10]

A modular scanner system for NDE has been developed. It consists of a selection of individual electronics and motor module components, supported by scanner configuration and control software. The modules are used as standard building blocks for construction of job specific, dedicated scanners as well and general purpose scanners. The use of modular scanner components significantly reduce the work, time and cost not only for the design and manufacture but also for establishing documentation and ensure compliance with the relevant EU-directive requirements. [Pg.805]

The finite size effects in the contact between a spherical lens of polyurethane and a soft flat sheet of crosslinked polyfdimethyl siloxane) (PDMS) has been addressed by Falsafi et al. [37]. They showed that for deformations corresponding to contact diameters larger than the sheet thickness, the compliance of the system was affected by the glass substrate supporting the soft sheet. In order to minimize the finite size effects in the adhesion measurement of small elastomeric lenses, Falsafi et al. [38] and Deruelle et al. [39] used relatively thick elastic sheets to support their samples. [Pg.89]

Once adopted there are many ways to implement and enforce energy codes. Where a state or local building code exists, there is already an adopted code and enfoixement mechanism in place to ensure compliance with the energy code. Where no such building code infrastructure exists, then implementation in the absence of such support must rely on the following mcchanisins ... [Pg.201]

Records. The manufacturer shall keep records of all calculations and tests. When requested by prospective purchaser or by a user of the equipment, the manufacturer shall examine the details of computations, drawings, tests, or other supporting data necessary to demonstrate compliance with the specification. It shall be understood that such information is for the sole use of the user or prospective purchaser for checking the API rating, and the manufacturer shall not be required to release the information from his custody. [Pg.535]

Demand compliance Sometimes demanding that people do what they agreed to do gets the desired results. You may have to appeal to higher management for backing and support. X X... [Pg.837]

For patients receiving oral antibiotics either prophylacti-cally or as treatment of febrile neutropenia, counsel them that initial or persistent fever should be reported promptly and that compliance with the regimen is critical. Patients also should have easy access to medical care and adequate caregiver support. Provide information on drug interactions and adverse effects. [Pg.1474]

Purchase or specification of a fire pump to support hydrocarbon operations should be in compliance with recognized international standards for such equipment. The most commonly referenced standards are listed below. All of these standards require a factory acceptance test of the unit. [Pg.208]

Abstract On average 50% of patients are compliant to long term medication treatment. Non-compliance is a drug-related problem as it may result in negative outcomes for the patient. Non-compliance can be intentional or non-intentional and related to knowledge, attitudes, and also practical problems including memory and administration difficulties. The decision to take a medication or not (compliance) lay in the hand of the patient, but the health care providers can support the patient in this decision with the aim to improve the patients health. Definitions and tools to detect negative patient and health-care behaviour and methods for concordance are presented in this chapter. [Pg.111]


See other pages where Compliance support is mentioned: [Pg.962]    [Pg.177]    [Pg.175]    [Pg.962]    [Pg.177]    [Pg.175]    [Pg.127]    [Pg.2166]    [Pg.537]    [Pg.159]    [Pg.132]    [Pg.147]    [Pg.622]    [Pg.129]    [Pg.69]    [Pg.124]    [Pg.177]    [Pg.241]    [Pg.21]    [Pg.350]    [Pg.50]    [Pg.8]    [Pg.56]    [Pg.580]    [Pg.565]    [Pg.283]    [Pg.608]    [Pg.1071]    [Pg.17]    [Pg.1]    [Pg.128]    [Pg.76]    [Pg.437]    [Pg.7]    [Pg.142]    [Pg.231]    [Pg.478]    [Pg.57]    [Pg.169]    [Pg.85]    [Pg.113]    [Pg.141]   
See also in sourсe #XX -- [ Pg.177 ]




SEARCH



© 2024 chempedia.info