Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Compartment micro

An HTS assay typically requires the detection of minute amounts of a probe at nanomolar or lower concentrations in the presence of a 10,000-fold or higher excess of other reagents chemical test compounds from the screening Hbrary at a level of 10-100 pm large amounts of proteins and lipids from cells or crude membranes containing only fractions of the target and a sample compartment (micro-titer plate), which is a disposable made of plastic and generates a totally different situation to a quartz cuvette in a spectroscopic set-up. [Pg.637]

Separation layer mixers use either a miscible or non-miscible layer between the reacting solutions, in the first case most often identical with the solvent used [48]. By this measure, mixing is postponed to a further stage of process equipment. Accordingly, reactants are only fed to the reaction device, but in a defined, e.g. multi-lamination-pattem like, fluid-compartment architecture. A separation layer technique inevitably demands micro mixers, as it is only feasible in a laminar flow regime, otherwise turbulent convective flow will result in plugging close to the entrance of the mixer chamber. [Pg.402]

Figure 4.30 Electrochemical micro reactor, a diaphragm micro flow cell, applied to perform the cation flow method. Assembled device (left). Disassembled device showing the two compartments of the cell within the housings and the diaphragm (right) [67. ... Figure 4.30 Electrochemical micro reactor, a diaphragm micro flow cell, applied to perform the cation flow method. Assembled device (left). Disassembled device showing the two compartments of the cell within the housings and the diaphragm (right) [67. ...
Berka et al [59] described an accurate and reproducible coulometric method, with chlorine electrogenerated at the anode, for the determination of micro quantities of primaquine phosphate. Titration was carried out in an anode compartment with a supporting electrolyte of 0.5 M sulfuric acid-0.2 M sodium chloride and methyl orange as indicator. One coulomb was equivalent to 1.18 mg of primaquine phosphate. The coefficients of variation for 0.02-0.5 mg of primaquine phosphate were 1-5%. Excipients did not interfere. [Pg.184]

Ramkrishna et al.m proposed a similar model at about the same time—this too was an unsegregated model which also divided the biomass into two compartments. They referred to the material in the two compartments as G-mass and D-mass, respectively, and suggested that these materials were formed in parallel. They also proposed that the micro-organism produced a toxic substance which inhibited its growth. They produced a set of differential equations obtained from material-balance considerations, to describe the behaviour of such a system in both batch and continuous culture. For batch culture ... [Pg.399]

The last term in equation 5.245 represents the dilution of active component /, by the expansion of the biomass. Esener et al.m also present a two-compartment model which takes this effect into account and they emphasise the need to devise the theory so that it can be tested by experiment. In their model they identify a K compartment of the biomass which comprised the RNA and other small cellular molecules. The other compartment contained the larger genetic material, enzymes, and structural material. The model assumes that the substrate is absorbed by the cell to produce, in the first instance, K material, and thence it is transformed into G material. Additionally, the G material can be reconverted to K material, a feature intended to account for the maintenance requirement of the micro-organism. A series of material balances for the cellular components during growth in a CSTF produced the following differential equations ... [Pg.401]

Fig. 50.1. Photograph of the Immuspeed instrument coupled to a portable computer comprising the Immusoft programme serving to load the test protocol, to run the assays, and to process the results. The figure also shows an artist view of the 8-channel Immuchip cartridge used in the current work and a schematic drawing of a micro-channel cross section with inlet, outlet, working electrodes, and electrical connection tracks the arrow shows the position of the cartridge insertion into the reception compartment of Immuspeed which comprises a temperature controller below the chip. Fig. 50.1. Photograph of the Immuspeed instrument coupled to a portable computer comprising the Immusoft programme serving to load the test protocol, to run the assays, and to process the results. The figure also shows an artist view of the 8-channel Immuchip cartridge used in the current work and a schematic drawing of a micro-channel cross section with inlet, outlet, working electrodes, and electrical connection tracks the arrow shows the position of the cartridge insertion into the reception compartment of Immuspeed which comprises a temperature controller below the chip.
The osteoclast is unique in mobilizing massive quantities of calcium from mineralized tissue. Dissolving hydroxyapatite requires the addition of protons, just as deposition of hydroxyapatite liberates acid (see Equation 1). To allow acidification, the osteoclast produces an isolated micro-compartment on the bone surface. This is achieved by close apposition to the matrix via adhesion of av integrins to matrix RGD peptides, with (33 the major complementary subunit (Miyauchi et al., 1991). Inside the osteoclast the cytoskeleton (Akisaka et al., 2006), and transport activities (Vaananen et al., 2000 Schlesinger et al., 1994) are reorganized to support the resorption compartment. [Pg.546]

Fig. 4. Compartmental model describing the cycling of nitrogen in a planktonic community in the mixed layer of a water column. Flow pathways are represented by arrows and numbers which correspond to mathematical expressions described in Table 2. The nitrogen pool represents all abiotic nitrogen (nitrate, ammonia and urea), and other compartments represent bacteria, zooflagellates, larger protozoa, and micro-mesozooplankton, giving off waste products (F+U). Arrows (13) and (14) depict sedimentation of zooplankton faeces and phytoplankton cells, respectively (After Moloney et al., 1985). Fig. 4. Compartmental model describing the cycling of nitrogen in a planktonic community in the mixed layer of a water column. Flow pathways are represented by arrows and numbers which correspond to mathematical expressions described in Table 2. The nitrogen pool represents all abiotic nitrogen (nitrate, ammonia and urea), and other compartments represent bacteria, zooflagellates, larger protozoa, and micro-mesozooplankton, giving off waste products (F+U). Arrows (13) and (14) depict sedimentation of zooplankton faeces and phytoplankton cells, respectively (After Moloney et al., 1985).
Values assigned to each of the 22 constants in the 19 expressions used in the simulation model, and the relevant sources. The flow pathways are represented as donor -> recipient compartments. N = nitrogen pool P = phytoplankton B = bacteria F = zooflagellates L = large protozoa Z = micro-mesozooplankton (F+U) = faeces and urine (nitrogen pool). All units expressed in terms of mg, m2 and/or d. [Pg.88]

A basic assumption related to both methods of analysis is that the elimination of drug from the body is exclusively from the sampling compartment (i. e., blood/ plasma), and that rate constants are first order. However, when some or all of the elimination occurs outside the sampling compartment - that is, in the peripheral or tissue compartment(s) - these types of analysis are prone to error in the estimation of Vss, but not CL. In compartmental modeling, the error is related to the fact that no longer do the exponents accurately reflect the inter-compartmental and elimination (micro) rate constants. This model mis specification will result in an error that is related to the relative magnitudes of the distribution rate constants and the peripheral elimination rate constant. However, less widely understood is the fact that this model mis specification will also result in errors in noncompartmental pharmacokinetic analysis. [Pg.181]

As stated above, the Vss calculation using Eqs. (5) or (10) is valid only when elimination exclusively occurs from the sampling (plasma/blood) compartment. When some or all elimination occurs from the tissue compartment (Fig. 7.1), the concentration versus time profile will still be characterized by a bi-exponential equation however, the ability of modeling systems to quantify the micro rate constants is lost. That is to say, essentially identical bi-exponential concentration time profiles are possible with and without elimination from the tissue compartment. Therefore, when modeling from a plasma profile only, there is no way of determining if the exit of drug from the body is exclusive to the central compartment. [Pg.185]

From an examination of Eq. (6) for a two-compartment model it is evident that Vss is dependent on the quantification of K12 and K21. For this model K12 and K21 can be determined by nonlinear regression analysis of plasma concentration-time data, either by deriving them from the fitted values of the coefficients and exponentials of the bi-exponential expression describing the concentration-time data, or by coding them directly into the modeling program. For the case where tissue elimination exists, it is possible to code into the model the existence of a K20, but the convergence process will not be able to resolve the appropriate micro rate constant. [Pg.185]

M 81] [P 70] A microscopy-image analysis of the color formation due to a reactive approach reveals that the micro mixer with helical elements and barriers gives a better performance than the micro mixer with helical elements but without barriers and a reference pipe structure without either helical elements or barriers (see Figure 1.167) [3], The pipe gives the expected profile with two colorless fluid compartments on top and at bottom, separated by a colored interface. This is indicative of the absence of any swirling, secondary flow. [Pg.223]

Reactor 7 [R 7] High-throughput Micro Reactor with Parallel Micro Compartments... [Pg.438]

Figure 3.26 Schematic of the high-throughput micro reactor with eight parallel flow passages, the micro compartments (right). Cross-section of the reactor showing details of the micro compartments (left). Dimensions are given in mm [55]... Figure 3.26 Schematic of the high-throughput micro reactor with eight parallel flow passages, the micro compartments (right). Cross-section of the reactor showing details of the micro compartments (left). Dimensions are given in mm [55]...
Figure 3.29 (a) Oxygen concentration profile at the inlet and outlet of the compartments of the high-throughput micro reactor. The inlets of the sampling tubes have to penetrate into the compartments to minimize flow cross-over, (b) Area averaged oxygen concentration at one capillary outlet. Total flow velocity 50 (1), 75 (2) and 100 cm3 min-1 (3) [55] (by courtesy of ACS). [Pg.441]

Fig. 2.15. Schematic automated isocratic and gradient elution nemo-liquid chromatograph/ capillary electrochromatograph according Alexander et al. (reproduced from Ref. [44] with permission of the publisher). 1, high-voltage power supply (negative polarity) 2, platinum electrode 3, outlet reservoir vial 4, UV detector with on-column flow cell 5, nanocolumn 6, two-position switching valve 7, jack stand 8, fused-silica make-up adapter (split device) 9, ground cable 10, internal loop micro-injection valve 11, plexiglas compartment 12, autosampler 13, dynamic mixer 14, micro-LC pumps. Fig. 2.15. Schematic automated isocratic and gradient elution nemo-liquid chromatograph/ capillary electrochromatograph according Alexander et al. (reproduced from Ref. [44] with permission of the publisher). 1, high-voltage power supply (negative polarity) 2, platinum electrode 3, outlet reservoir vial 4, UV detector with on-column flow cell 5, nanocolumn 6, two-position switching valve 7, jack stand 8, fused-silica make-up adapter (split device) 9, ground cable 10, internal loop micro-injection valve 11, plexiglas compartment 12, autosampler 13, dynamic mixer 14, micro-LC pumps.

See other pages where Compartment micro is mentioned: [Pg.97]    [Pg.102]    [Pg.289]    [Pg.106]    [Pg.401]    [Pg.389]    [Pg.186]    [Pg.128]    [Pg.409]    [Pg.208]    [Pg.256]    [Pg.203]    [Pg.1]    [Pg.137]    [Pg.600]    [Pg.470]    [Pg.22]    [Pg.86]    [Pg.88]    [Pg.324]    [Pg.38]    [Pg.4]    [Pg.105]    [Pg.438]    [Pg.438]    [Pg.439]    [Pg.439]    [Pg.532]    [Pg.407]    [Pg.420]    [Pg.36]    [Pg.224]   
See also in sourсe #XX -- [ Pg.201 ]




SEARCH



© 2024 chempedia.info