Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Comparison to classical

It is clear that the variation in the carbene stabilization modes dramatically modify the carbene properties in terms of steric and electronic factors, which is very essential in the design of new ligands for transition metals. In comparison to classical NHCs, non-NHC carbenes offer a large range of possible structural variations, which should rapidly enhance the interest in non-NHC-based complexes. We can anticipate that the fine tuning of the properties of stable non-NHC carbenes makes these ligands very promising for the development of novel and efficient catalysts. [Pg.145]

List some advantages of MMCs in comparison to classical organic composites. [Pg.257]

Early in the 20th century chemists began to research and exploit physical properties of the analyte properties, such as conductivity, electrode potential, light absorption or emission, mass-to-charge ratio and fluorescence for solving analytical problems. Classical principles remain useful in modem analytical instruments and methods. In comparison to classical methods the output of instrumental methods is a signal from which the result of the analyses is calculated. Instrumental analysis is most useful for elemental determinations at minor and trace levels (about 1% all the way down to 1 atom)—in this range classical analysis does not perform well. [Pg.527]

Typical reaction conditions of the RCH/RP process37,38,336 are T=120°C P=50 bar / =1.01 P/Rh=50-100 aqueous/organic phase=6 concentration of rhodium 10-1000 ppm pH of the aqueous phase 4-10. The RhH(CO)(tppts)3 catalyst345 is prepared in situ from rhodium-2-ethylhexanoate, for example, by addition of tppts in water. The process engineering is enormously simplified in comparison to classical oxo plants. Figure 1 shows the flowsheet of the RCH/RP oxo process.38,424... [Pg.140]

Amphiphilic block copolymers can be also considered as a particular class of surfactant [135], They are composed, as it is very well known, of at least one hydrophobic block and one hydrophilic block, and for this reason, they are usually called polymeric surfactants or macrosurfactants . In comparison to classical surfactants,... [Pg.198]

Analysis of Pesticides. Organophosphates, carbamates, atrazine derivatives, and other types of compounds are receiving expanded use in comparison to classical organochlorine pesticides. Many of these compounds are not amenable to GC analysis due to thermal instability or other factors. HPLC holds promise for analysis of such substances. HPLC procedures for selected pesticide analyses are presented in the following. [Pg.103]

Figure 21-17. Concentration profile of an artificial two-component mixture (A and B) with linear conditions assumed. The SMB system consists of 12 columns (3 per zone). The profiles symbolize the movement of the peaks from the start to the end of a tact. More columns in combination with shorter shifting times will resnlt in an optical nonmoving steady state concentration profile. It is obvious from the figure that an SMB system makes optimal use of the total stationary phase in the system and has to be much more economic in comparison to classical batch elution. Figure 21-17. Concentration profile of an artificial two-component mixture (A and B) with linear conditions assumed. The SMB system consists of 12 columns (3 per zone). The profiles symbolize the movement of the peaks from the start to the end of a tact. More columns in combination with shorter shifting times will resnlt in an optical nonmoving steady state concentration profile. It is obvious from the figure that an SMB system makes optimal use of the total stationary phase in the system and has to be much more economic in comparison to classical batch elution.
In comparison to classical IRMS methods, the instrumental configuration of cGC-IRMS combines the precision of IRMS to the high purification effect of cGC-separa-tion, with large savings on laborious sample clean-up procedures. [Pg.690]

According to calculations, the free path A in a defect-free carbon nanotube is about Igm, while values of about 100 nm have been determined experimentally. This is an extremely large value in comparison to classical electric conductors (e.g., Uthium llOA, copper 430A, silver 560A). [Pg.204]

The lack of a clear image in quantum molecular dynamics has been a handicap for most researchers. This is in comparison to classical molecular dynamics which is strongly linked to the notion of a trajectory, a causal path leading from reactants to products. Imaging the flow of a trajectory constitutes one of the main sources of insight on classical molecular dynamics. [Pg.185]

Kricheldorf, H.R. and Eggerstedt, S., MALDI-TOF Mass Spectrometry of Tin-Initiated Macrocyclic Polylactones in Comparison to Classical Mass Spectroscopic Methods, Macromol. Chem. Phys., 200, 1284, 1999. [Pg.317]

Mechatronic systems excel by various advantages in comparison to classical, electromechanical products (VDI 2004) ... [Pg.863]

The evaluation of solute-micelle binding constants has important implications outside the field of chromatography, such as micellar catalysis, tertiary oil recovery, and enzyme and membrane modeling. MLC is a powerful technique for the determination of these constants, in comparison to classical methods. The use of MLC in this field has several advantages ... [Pg.142]

Dooley L., Lee, Y.S. and Meullenet, J.F. (2010), The application of check-all-that-apply (CATA) consumer profiling to preference mapping of vanilla ice cream and its comparison to classical external preference mapping, Food Qual Prefer, 21, 394 01. [Pg.243]

Polar selectivity is generally understood to refer to the differing retention of polar analytes relative to neutral analytes in comparison to classical reversed... [Pg.211]

In conclusion, the arrival of the UPLC in laboratories has permitted the improvement of the quality and the productivity of analyses, with an increased sensitivity, a better selectivity, a high throughput, and simplification of sample preparation. To increase the productivity of mass spectrometers, UPLC can also be a solution, with a reduction of run time, a better resolution, and better sensitivity, in comparison to classical HPLC systems. [Pg.273]

It has been demonstrated that ANN models can predict chemical values and physical properties even when some data is unknown compared with the MLR developed. This predictive procedure shows an improvement of prediction results around 86.66% in comparison to classical MLR model, that is, the neural network will be able to adjust more precisely those ternary solutions of ionic hquids in which one can ignore any value. [Pg.457]


See other pages where Comparison to classical is mentioned: [Pg.253]    [Pg.433]    [Pg.188]    [Pg.298]    [Pg.85]    [Pg.253]    [Pg.96]    [Pg.790]    [Pg.114]    [Pg.120]    [Pg.63]    [Pg.22]    [Pg.253]    [Pg.82]    [Pg.27]    [Pg.688]    [Pg.28]    [Pg.221]    [Pg.212]    [Pg.225]    [Pg.336]    [Pg.4098]    [Pg.283]    [Pg.510]    [Pg.243]    [Pg.148]    [Pg.585]    [Pg.219]   


SEARCH



© 2024 chempedia.info