Columns removal

The first column removes ethane which, after treatment for storage, may be used as feed for an ethylene plant. The heavier hydrocarbons pass to the next fractionating... [Pg.255]

To illustrate this integration analytically, Eq. (22-48) becomes Eq. (22-49) for the case of a stripping column removing a colhgend which is subject to the liuear-equifibrium isotherm T = KC. [Pg.2019]

A packed absorption column removes an impurity from a gas stream by contact with a liquid solvent. The column is 3 ft in diameter and contains 25 ft of No. 2 plastic Super Intalox packing. The gas has an MW of 28, enters the column at 120°F, and leaves at 10 psig at a rate of 5000 scfm. The liquid has an SG of 1.15 and a viscosity of 0.8 cP. Determine ... [Pg.411]

Develop a model and program this for the case of a countercurrent column removing two components. Use a dynamic model to avoid the difficulty of making iterations for steady state. [Pg.558]

In the residual occurrence matrix comprised solely of independent columns, if a row contains only one nonzero element, the stream corresponding to the column in which the nonzero element appears is the only stream that can be torn to break the loop corresponding to that row. The next step of the algorithm is (1) to remove the columns in which a lone nonzero element in a row appears and (2) to remove all of the rows that have nonzero elements in that column. Each column removed in this step corresponds to tearing the stream represented by the column, and all of the rows removed represent loops that are broken by the tear. [Pg.222]

C THE COLUMNS OF THE ITERATES ARE PLACED AT THE END OF THE BLOCK C 4 AND THE COLUMN OF THE OUTPUT VARIABLE PLACED NEXT IN THE SEQUENCE C THE COLUMNS REMOVED ARE SUBTRACTED FROM THE N+3 COLUMN. [Pg.244]

Ammonium d-a-bromocamphor-n-sulphonate [14575-84-9] M 328.2, m 284-285°(dec), [oc]q +84.8 (c 4, H2O). Passage of a hot aqueous soln through an alumina column removed water-soluble coloured impurities which remained on the column when the ammonium salt was eluted with hot water. The salt was crystd from water and dried over CaCl2 [Craddock and Jones JACS 84 1098 1962]. [Pg.92]

The drying column removes carbon dioxide, moisture, and some of the other by-products which are formed. The product which is collected is nearly pure, and the redistillation completes the purification. [Pg.41]

Bleaching column Remove dissolved NOx to give product acid. [Pg.55]

If flow is completely blocked, you will have to open the column, remove the frit, and bore out the plug with a flat ended spatula. Be very careful, the plug is generally only 1-2 mm deep. The packing can be washed with solvent or water, drained, and pasted back into the column like you are healing an end-void. [Pg.82]

A schematic drawing is shown in Figure 2. The small amounts of ester formed are reverted with a caustic-treating plus water wash. Distillation in a light ends column removes unreacted olefins, paraffin byproduct, plus other light components present in the crude alcohol. A second distillation is used to remove trace heavy components. Hydrogenation eliminates trace unsaturation, aldehydes, etc. Filtration assures clear, solids free product. [Pg.165]

The use of the HEA Column plus the DCN Reactor in series (see Figure 9.8) allows the optimization of the operating conditions and the operating cost. The HEA Column removes the majority of the NOx and stabilizes the NOx content in the tail gas. The DCN reactor destroys the remaining NOx as required to meet the emission limits. A comparison of the operating conditions for the Monsanto technology is given in Table 9.7". [Pg.238]

Burettes are very seldom tip- or end-heat strengthened as are pipettes, and they are therefore more prone to chipping or cracking. Burettes with removable tips and/or stopcocks can be useful for salvaging burettes that otherwise would be thrown away. Because the burette s calibration is exclusively on the column, removable tips and stopcocks have no effect on the buret s tolerance quality, nor should they imply the level of quality. [Pg.116]

Chromatographic separation was obtained also in this series by using prepacked silica gel columns. Removal of the protecting groups yielded the two racemic endproducts 235. As in the case of the secondary alcohol derivatives correlation of the separated epimers was not possible. [Pg.85]


See other pages where Columns removal is mentioned: [Pg.447]    [Pg.383]    [Pg.491]    [Pg.405]    [Pg.429]    [Pg.202]    [Pg.374]    [Pg.286]    [Pg.116]    [Pg.264]    [Pg.205]    [Pg.205]    [Pg.222]    [Pg.109]    [Pg.392]    [Pg.392]    [Pg.65]    [Pg.514]    [Pg.675]    [Pg.693]    [Pg.109]    [Pg.1026]    [Pg.383]    [Pg.491]    [Pg.108]    [Pg.210]    [Pg.83]    [Pg.165]    [Pg.186]    [Pg.274]    [Pg.6]    [Pg.79]    [Pg.116]    [Pg.478]   