Column change time

Occasionally, samples are run that adsorb onto the packing material. Generally, if one of the performance characteristics of the column changes by 10% or more, it is prudent to clean the column. These performance characteristics are (1) asymmetry factor, retention time, resolution, and theoretical plates. [Pg.134]

Snyder et al. (146) derived a rather simple relationship between the elution time of an eluite and the rate of change of solvent composition in gradient elution. They found the elution time, is related to the column dead-time, and an experimental parameter b by... [Pg.96]

There are four columns of data, one column for time and the other three for the voltage data for the selected traces. Once again we need to modify the first row so that the text labels fit within the columns. When we remove the leading spaces from the text labels and we change the column widths in the spreadsheet, the labels for the columns are easily seen ... [Pg.151]

When operating continuously at steady state each particle in a bed is subject to constant conditions but the concentration of reagents changes with the position in the column. When substrate is converted to product in a single pass the pattern of conversion down the bed resembles that seen when the same reaction is followed with respect to time in a batch reactor. This stems from the fact that distance travelled through the column is equivalent to processing with an equal concentration of biocatalyst in the batch reactor for the period of the column contact time. [Pg.401]

The experimental order of this study was also changed from the ideal randomised and blocked design. This was justified for reasons of automation where column changes needed to be minimised. As for the aspirin study the validity of this compromise depends on the fact that the repeatability of the method, over a time span such as that required for the ruggedness test, had previously been established. [Pg.228]

Column performance is affected by the carrier gas flowrate and there is always an optimum flowrate for every column. Retention times also are affected by the carrier gas flowrate. A 1% change in carrier gas flowrate will cause a 1% change in retention time. For all these reasons it is important to keep the flow of the carrier gas constant. There are basically two ways to assure... [Pg.293]

Column changes are a viable methods development tool in HPLC. Column can be switched at any time. Attach the new column with a slow flow of solvent from the injector outlet line to All the inlet fitting of your column so you don t leave air in the column entrance. Figure on flushing a column with at least six column volumes of a new solvent to re-equilibrate the column before injecting a sample. Plan on ignoring the first injection. Usually, the second, third, and subsequent injections will be reproducible. [Pg.209]

Problem 9 Column retention time and plate count changing. [Pg.223]

Affinity chromatography techniques have shown less utility in analytical testing than in preparative separations for a variety of reasons, including cost and the difficulty of validating consistent operation as the column changes over time. Protein A affinity has been commonly used to quantitate the total antibody content of either ascites or cell culture fluids. To provide guidance in the development of a purification process, specific immunoaffinity resins are either available or can be readily prepared to quantitate the levels of unrelated protein contaminants. To rapidly determine what the active species in a mixture is, a monoclonal antibody that... [Pg.91]

Column entry fields for dates, times, and events (e.g., initial installation and calibration, updates, column changes, errors, repairs, performance tests, quality control checks, cleaning, and maintenance, plus fields for the name and signature of the technician making the entry). [Pg.458]

Lithium citrate buffers (Li-A, Li-B, and Li-C) and a lithium cation exchange column (20 X 4.6 cm) were purchased from Beckman. The amino acid standard was prepared from the Beckman standard with the addition of Hyl/flZZo-Hyl (from Sigma). Optimization of the method with respect to temperature and buffer change times was required to adequately resolve Hyl from ammonia. Hyl is partially converted to allo-Hyl during hydrolysis. The peak areas for Hyl and allo-Hyl were combined for standards and samples. [Pg.93]


See other pages where Column change time is mentioned: [Pg.84]    [Pg.225]    [Pg.43]    [Pg.710]    [Pg.237]    [Pg.183]    [Pg.239]    [Pg.1250]    [Pg.116]    [Pg.449]    [Pg.515]    [Pg.200]    [Pg.31]    [Pg.84]    [Pg.174]    [Pg.307]    [Pg.215]    [Pg.87]    [Pg.1250]    [Pg.168]    [Pg.26]    [Pg.169]    [Pg.221]    [Pg.119]    [Pg.323]    [Pg.283]    [Pg.180]    [Pg.138]    [Pg.221]    [Pg.139]    [Pg.109]    [Pg.301]    [Pg.301]    [Pg.3556]    [Pg.4914]    [Pg.3580]    [Pg.476]    [Pg.224]   
See also in sourсe #XX -- [ Pg.209 , Pg.231 ]