Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Collision/reaction cell octopole

Collision/reaction cell Agilent ceVcs2 octopole cell (ORS) Elan DRC II quadrupole dynamic reaction cell XSeries11 hexapole cell ( XS-Minus modus) Varian-820-MS using collision reaction interface... [Pg.129]

Figure 10.43 The Agilent Technologies 8800 ICP-QQQ. From the left, sample introduction, the ICP torch box (note the cooling coils for the torch), Q1, the QRS octopole collision/reaction cell, Q2, and finally, the electron multiplier detector. ( 2014 Agilent Technologies, www.agilent.com/chem. All rights reserved. Used with permission.)... Figure 10.43 The Agilent Technologies 8800 ICP-QQQ. From the left, sample introduction, the ICP torch box (note the cooling coils for the torch), Q1, the QRS octopole collision/reaction cell, Q2, and finally, the electron multiplier detector. ( 2014 Agilent Technologies, www.agilent.com/chem. All rights reserved. Used with permission.)...
Other gas-phase ion chemical reactions were explored by using oxygen introduced into the octopole collision cell product ions were injected into and analyzed by the quadrupole ion trap [55]. Reaction of oxygen with Y+, Zr+, and Xe+ was found to proceed rapidly, forming YO+, ZrO+, and Xe neutrals, effectively eliminating interferences by the atomic ions. These ions are particularly difficult... [Pg.350]

When 1 -butene was used as reaction partner and thermalization gas in the first octopole, a new signal with the mass corresponding to the propylidene complex 17 appeared in the spectrum, indicating that an olefin metathesis reaction had occurred. This reactivity was confirmed by mass-selecting either 15 or 16 in the first quadrupole and reaction with 1-butene in the collision cell. The... [Pg.192]

Two papers have been published on the speciation of sulfur using ICP-DRC/CC-MS as a detector. ICP-MS with an octopole cohision cell was used for the detection of a CE separation of metallothionein-like proteins. The collision gas (Xe) and cell conditions were selected to reduce oxygen interference ( 02+) on the main sulfur isotope A completely different approach was taken by Hann et al. who introduced O2 as the reaction gas in the collision ceU, and measured the reaction product As obtaining metal-to-sulfur ratios in... [Pg.309]

Anicich, V. G. (2003) An index of the literature for bimolecular gas phase cation-molecule reaction kinetics. JPL Publication, Jet Propulsion Laboratory, Pasadena, CA, pp. 03-19. Yamada, N., Takahashi, J., and Sakata, K. (2002) The effect of cell-gas impurities and kinetic energy discrimination in an octopole collision cell ICP-MS under non-thermalised conditions. J. Anal. At. Spectrom., 17,1213-22. [Pg.382]


See other pages where Collision/reaction cell octopole is mentioned: [Pg.124]    [Pg.127]    [Pg.124]    [Pg.127]    [Pg.86]    [Pg.6089]    [Pg.392]    [Pg.745]    [Pg.828]    [Pg.829]    [Pg.55]    [Pg.657]    [Pg.381]    [Pg.424]    [Pg.381]    [Pg.6090]    [Pg.6090]    [Pg.49]    [Pg.6089]    [Pg.189]    [Pg.55]    [Pg.18]    [Pg.812]    [Pg.812]    [Pg.16]    [Pg.95]    [Pg.169]    [Pg.179]    [Pg.193]    [Pg.238]    [Pg.238]    [Pg.95]    [Pg.812]    [Pg.812]    [Pg.745]    [Pg.107]   
See also in sourсe #XX -- [ Pg.124 , Pg.127 ]

See also in sourсe #XX -- [ Pg.124 , Pg.127 ]




SEARCH



Cell reaction cells

Cell reactions

Collision cell

Collision cell octopole

Collision octopole

Collision/reaction cell

Collision/reaction cell reactions

Octopole

© 2024 chempedia.info