Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Differential collection system

The separation step requires (1) application of a force that produces a differential motion of the particles relative to the gas, and (2) sufficient gas-retention time for the particles to migrate to the collecting surface. Most dust-collections systems are comprised of a pneumatic-conveying system and some device that separates suspended particulate matter from the conveyed air stream. The more common systems use either filter media (e.g., fabric bags) or cyclonic separators to separate the particulate matter from air. [Pg.777]

Filter layers, frost penetration, and cap-liner connections are other factors to consider in designing the closure system for a hazardous waste landfill. Before using geotextiles for filter layers in closures, one should conduct pressure tests and clogging tests on the material. Freeze-thaw cycles probably have little effect on membranes, but their impact on clay is still not known. Because of this lack of knowledge, membrane and clay layers should be placed below the frost penetration layer. Finally, a cap membrane should not be welded to the primary FML. Differential settlement in the cap can put tension on the cap membrane. In such a situation, the seam could separate and increase the potential for integration of the surface water collection system into the LDS. [Pg.1146]

Differential scanning calorimetry of acetylcholine chloride was performed using a Dupont DSC Model TA 9900 thermal analyzer system, interfaced to a Dupont data collection system. Figure 2 shows the DSC thermogram, which was recorded from 50 to 350°C. [Pg.10]

Figure 1. The rotating disk impactor coupled with a modified midget impinger as a differential collection system... Figure 1. The rotating disk impactor coupled with a modified midget impinger as a differential collection system...
A widespread solution, in terms of appKcation and market volume, can be the recycling of single materials or homogeneous fractions obtained from a differentiated collection system and/or a separation... [Pg.708]

The samples were evaluated with the differential rheometer in the following manner Samples of SE-30 and the material of interest were weighed to 0.3 0.0005 g. For each experimental run the samples were loaded into the sample gaps and the control system activated at the initial sample thickness. The loading of the samples invariably introduced an initial deflection in the load cell blade. The samples were therefore allowed to relax until the blade had returned to the zero position (2-3 min). The input waveform from the function generator was then started at the frequency and amplitude of interest. The APPLE-based data collection system was started at the end of 1 cycle and continued for 4-10 cycles at 50-250 points/cycle. After data collection the samples were removed, the pushrods cleaned and fresh samples loaded. The second pair of samples were inserted with the sample sides reversed and data was collected as before. After all runs were completed the pair of data files for each sample set were subtracted point by point to eliminate much of the coherent noise caused by nonuniformity of the two rod motions. The resultant voltage file was transmitted to the University of Connecticut, Department of University Computer Systems IBM 3081. The voltages... [Pg.99]

A negative aspect of deposit systems is that the per-container cost of managing these systems, as they are currently designed, is higher than the cost of alternative collection systems.A national system rather than the current multiplicity of state systems could reduce some of this cost differential, however. There are also very real sanitary concerns, especially when deposits are expanded to noncarbonated beverages. [Pg.493]

In trauma of the kidney, excretory-phase imaging after 3 to 10 min can provide valuable information about the extent of the injury into the renal collection system (Fig. 42.3) (Park et al. 2006). When injuries to the spleen and liver are present, late-phase images help to plan interventions because they allow differentiating pseudoaneurysms from lacerations and active contrast material extravasations (Marmery and Shanmuganathan 2006). [Pg.592]

Fig. 1.2.4. Volumetric differential function. The time point for calculation of renal volumes is determined visually by defining the time when the kidneys have enhanced maximally and before contrast has been excreted into the collecting systems. At this time the kidneys are easily separated from the background with semi-automated techniques that produce volume calculations for each kidney depending on a user-defined threshold... Fig. 1.2.4. Volumetric differential function. The time point for calculation of renal volumes is determined visually by defining the time when the kidneys have enhanced maximally and before contrast has been excreted into the collecting systems. At this time the kidneys are easily separated from the background with semi-automated techniques that produce volume calculations for each kidney depending on a user-defined threshold...
The second parameter that maybe obtained from a renographic curve is the evaluation of tracer molecule transport through the entire nephron, known as the transit time. A normal transit time (approximately 3 min) excludes renal obstruction. Abnormal transit time indicates urine statis. It is not possible on the basis of a prolonged transit time to differentiate obstruction from simple dilatation of the collecting system. [Pg.95]

Abnormal duplex kidneys used to be and are still detected during the work-up of urinary tract infection or urinary dribbling in girls. They are more and more often demonstrated during fetal life. In utero, it is possible to differentiate between the two collecting systems particularly if one is dilated. It is even possible to differentiate between ectopic ureter and ucele in utero (Joseph et al. 1989 Avni et al. 1991 Abuhamad et al. 1996 Vergani et al. 1999 Caione et al. 1989 Jee et al. 1993). Other forms of presentation include interlabial mass in girls or bladder outlet obstruction. Both conditions are related to urethral prolapse of the ucele (Nussbaum 1983). [Pg.109]

Differentiation between obstructive and non-obstructive pyelocaliectasis remains difficult and Doppler RI measurement is neither sensitive nor specific in transplanted kidneys (Platt et al. 1991). Renal scintigraphy may characterize the obstruction when the tracer accumulates within the collecting system on delayed images and by measuring increased clearance time after furosemide injection. [Pg.60]

Hamiltonian, but in practice one often begins with a phenomenological set of equations. The set of macrovariables are chosen to include the order parameter and all otlier slow variables to which it couples. Such slow variables are typically obtained from the consideration of the conservation laws and broken synnnetries of the system. The remaining degrees of freedom are assumed to vary on a much faster timescale and enter the phenomenological description as random themial noise. The resulting coupled nonlinear stochastic differential equations for such a chosen relevant set of macrovariables are collectively referred to as the Langevin field theory description. [Pg.735]


See other pages where Differential collection system is mentioned: [Pg.1229]    [Pg.171]    [Pg.221]    [Pg.227]    [Pg.279]    [Pg.383]    [Pg.1052]    [Pg.144]    [Pg.366]    [Pg.814]    [Pg.623]    [Pg.623]    [Pg.1233]    [Pg.802]    [Pg.17]    [Pg.22]    [Pg.107]    [Pg.132]    [Pg.194]    [Pg.203]    [Pg.221]    [Pg.246]    [Pg.267]    [Pg.301]    [Pg.385]    [Pg.1868]    [Pg.80]    [Pg.553]    [Pg.351]    [Pg.427]    [Pg.132]    [Pg.1294]    [Pg.199]   
See also in sourсe #XX -- [ Pg.221 ]




SEARCH



Collective system

Differential system

© 2024 chempedia.info