Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chromatography operation

Conventional multidimensional gas chromatography operation procedures should now be reconsidered and redefined in light of the new method of comprehensive GC X GC technology, as discussed below. [Pg.80]

The scale-up of chromatography operated in isocratic elution can be carried out as follows. [Pg.245]

Chromatography operates on the same principle as extraction, but one phase is held in place while the other moves past it.4-5 Figure 23-5 shows a solution containing solutes A and B placed on top of a column packed with solid particles and filled with solvent. When the outlet is opened, solutes A and B flow down into the column. Fresh solvent is then applied to the top of the column and the mixture is washed down the column by continuous solvent flow. If solute A is more strongly adsorbed than solute B on the solid particles, then solute A spends a smaller fraction of the time Dee in solution. Solute A moves down the column more slowly than solute B and emerges at the bottom after solute B. We have just separated a mixture into its components by chromatography. [Pg.506]

As the ligand-protein interaction takes place at the internal surface of porous adsorbents, kinetics and equilibrium of the interaction should be independent of the interstitial voidage within an adsorbent bed. Therefore the equilibrium capacity of an adsorbent will not be influenced by different experimental configurations e.g. batch stirred tank, batch fluidized bed, frontal application to packed or fluidized beds. The major difference arises from the medium from which the protein is isolated. As fluidized beds are used for whole broth adsorption, the properties of the broth have to be considered regarding the possible influence of components which are removed in conventional primary recovery steps and therefore are not present during the initial chromatography operations in a standard downstream process. These are on one hand nucleic... [Pg.202]

Depending on the required level of purity, the step used for removing impurities can be a single or multiple-step chromatography operation. Table 32.8 summarizes chromatographic methods that can be used to remove impurities following the capture step.76-78 80... [Pg.1443]

Electrochemical detectors used in chromatography operate by voltam-metric principles and currents are produced as the mobile phase flows over electrodes set at a fixed potential to achieve maximum sensitivity, this potential must be set at a level that allows electrochemical reactions to occur in aU analytes of interest. [Pg.233]

Stationary phases used for achiral, small molecule separations are often further separated into two major classifications normal and reversed phase. Normal-phase chromatography uses a polar stationary phase with a less polar mobile phase, while reversed-phase chromatography operates using the exact opposite conditions. Additionally, there are several functionalized stationary phases that can operate in either normal or reversed phase, e.g., cyano and amine resins. [Pg.234]

Finding an online detection method is an important step in carrying out any analytical or preparative chromatography operation. In a preparative operation, a reliable online detector can be used to determine at which time the desired product is eluting from a chromatography column. [Pg.239]

Fig. 5.10 Development of concentrations during closed loop recycling chromatography operation with peak shaving. Fig. 5.10 Development of concentrations during closed loop recycling chromatography operation with peak shaving.
Columns used for internal chromatography operations are most conveniently dry-packed outside the glovebox. Both ends should be fitted with a 3-way chromatography valves(11) to facilitate sample injection and effluent distribution operations. After purging the... [Pg.144]

The exact mode of chromatography operating in a given application is determined principally by the nature of the packing, though it must be appreciated that, while there may be one dominant mechanism, the modes are not mutually exclusive. [Pg.119]

The resulting mixture is sent to microlilters to remove large quantities of wastewater, which passes through the filters. For this step, alternate separators, like gel filtration and an Acticlean Etox resin (by Sterogene) should be considered. The retentate from the filter, which contains tPA, other proteins, endotoxin, arginine hydrochloride, and some water, is sent to an affinity chromatography operation. Here, tPA is selectively adsorbed on a resin... [Pg.89]

With the long column commonly used in the chromatography operation, the use of eq. (14.2-3a) is satisfactory. [Pg.778]

Thus the chromatography operation is optimal when the function in the RHS of eq. (14.3-15) has a minimum. The optimal velocity is ... [Pg.785]


See other pages where Chromatography operation is mentioned: [Pg.62]    [Pg.59]    [Pg.55]    [Pg.152]    [Pg.110]    [Pg.11]    [Pg.25]    [Pg.5]    [Pg.380]    [Pg.18]    [Pg.557]    [Pg.468]    [Pg.417]    [Pg.417]    [Pg.513]    [Pg.858]    [Pg.239]    [Pg.23]    [Pg.434]    [Pg.463]    [Pg.196]    [Pg.196]    [Pg.204]    [Pg.206]    [Pg.613]    [Pg.260]    [Pg.1281]    [Pg.411]    [Pg.148]    [Pg.1460]    [Pg.775]    [Pg.788]    [Pg.468]   


SEARCH



Chromatography batch operation

Chromatography continuous operation

High performance liquid chromatography operating modes

High-performance liquid chromatography continuous operation

High-performance liquid chromatography operational sensitivity

Hydrophobic interaction chromatography operation

Micellar electrokinetic chromatography operating conditions

Operation of the liquid chromatography-electrochemical system

Reversed-phase chromatography operation

Size exclusion chromatography operations

© 2024 chempedia.info