Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Change of measure

Equivalent to section (5.1), we first have to change the measure of the (log) bond price process, before we are able to compute the option prices. Therefore, we transform the (log) bond price dynamics [Pg.80]

plugging the RE dwJ° t,T) under the forward measure Tq in the (log) bond price dynamics (6.9) leads to [Pg.80]

We additionally assume that the regularity conditions hold for the volatility and correlation function. [Pg.80]


In the majority of sensor applications employing bridges, the deviation of one or more resistor in the bridge from an initial value must be measured as an indication of the magnitude or change of measurement. In figure 2.18, if we let / = / ( +Jt), and R2 = R3 = R4 = R, where x is the fractional deviation around zero, as a function of (say) strain, then,... [Pg.44]

The concentrations measured in the plume downstream of a contaminated site are an important parameter for evaluation of the site. The concentrations of the contaminants are traditionally used as indicators for commencement of remediation or protection measures. Together with the concentrations of electron acceptors they are also indicators for degradation processes in the subsurface. However, a virtual heterogeneous aquifer will be used to investigate the changes of measured concentrations due to variation of screen emplacement in an observation well and due to different pumping rates. [Pg.156]

The change in measure amounts to a change in numeraire by using a zero-coupon bond P t, Ti) with a specified maturity. Mathematically, the change of measure modifies the probability such that the expectation of the product can be computed as the product of the expectations under the new measure. [Pg.29]

Figure 11. Change of measured and calculated yields of the main products, degree of decomposition, and true reaction time of naphtha cracking with the relative length of the reactor experiment No. 44... Figure 11. Change of measured and calculated yields of the main products, degree of decomposition, and true reaction time of naphtha cracking with the relative length of the reactor experiment No. 44...
The reversible conversion of the system properties caused by the conformational changes is described by the curves having approximately the same shape, irrespeetive of the stimulus nature, Figure 4.11. The plotted curves differ eaeh to another by the amplitude and the frequency of the changes of measured property. Presently, the efforts are focused on the inerease both of amplitude of dimensional changes and developed foree, and shortening of mechanochemical cycle. [Pg.380]

The last source arises from variations in the measurement conditions between both calibration and prediction steps (changes in temperature, changes of measurement cell, etc.). For instance, physical parameters such as temperature can have a strong influence on the bond vibrations, and therefore on the shape of the resulting NIR spectra [17]. If the temperature or temperature range of the predicted samples is not identical to that of the measured samples in the calibration step, predictions obtained with the spectra collected in the prediction step will be erroneous. [Pg.233]

We will now analyze the control of variables that are the integral of flow. Liquid level is the integral of liquid flow, whereas the integral of gas flow in a constant-volume system is pressure. These loops have certain features not common to other classifications. For example they can be non-self-regulating. This is never true of flow and rarely true of other variables. Second, the rate of change of measurement is a function of the difference between inflow and outflow either inflow or... [Pg.61]

The majority of classical reference electrodes use aqueous solutions of ions participating in the potential-determining reactions. The coimection of such electrodes with the electrochemical cell occurred either by a direct contact of the solution filling the electrode or by the use of an electrolytic bridge. Though different junctions were used, in order to minimize the contamination of the studied solution, the problem of a proper contact still exists. The diffusion and change of concentration of electrolytes at the liquid junction lead to some change of measured emf. [Pg.91]

Table 4 Effect of Solid-Phase Microextraction Sampling Time on the Changes of Measured Gas Phase Concentrations Using a lO-gm Polydimethyl Siloxane Fiber... Table 4 Effect of Solid-Phase Microextraction Sampling Time on the Changes of Measured Gas Phase Concentrations Using a lO-gm Polydimethyl Siloxane Fiber...
On the other hand, it has been observed [80] that the relative BE3 affinities for 13 representative bases are almost insensitive to the change of measurement medium from dichloromethane to nitrobenzene (see Chapter 3). [Pg.34]

Once again the case rriK < oo is easier, since there is no need of making a change of measure. One readily sees that (5.11) holds if one chooses... [Pg.107]


See other pages where Change of measure is mentioned: [Pg.208]    [Pg.27]    [Pg.393]    [Pg.43]    [Pg.43]    [Pg.80]    [Pg.97]    [Pg.97]    [Pg.70]    [Pg.70]    [Pg.71]    [Pg.166]    [Pg.170]    [Pg.303]    [Pg.2513]   


SEARCH



Measure of Absorbance Change

Measurement of Temperature and Enthalpy Change

Measurement of changes in electrical conductivity

Measurement of energy changes

Measurement of magnetic changes

The Measurement of Work-Function Changes

The change of measure

© 2024 chempedia.info