Both programs would require the installation of some form of bleed control to limit the cycles of concentration and to remove sludges from the cooling system. The results are presented in Table 3.3. [Pg.83]

Apart from the primary components of a cooling water system, all ancillary equipment such as level controllers, bleed systems, dosing and control systems, low-level alarms, pH controllers, and on-site biocide generation systems should be regularly inspected, cleaned, calibrated, and maintained in good working order. [Pg.319]

In another microemulsion system, ° the colorant is incorporated into the ink as an aqueous pigment dispersion-based inkjet ink composition by formulating the ink to comprise at least one aqueous pigment dispersion and a microemulsion with at least one water-insoluble organic compound, one hydrotropic amphiphile, and water. This ink system was reported to improve waterfastness and bleed control, "" providing a fast drying ink. [Pg.208]

PRESSURE AND INVETORY CONTROL SYSTEM CSA Class 1,3 DBE The system safety functions are to provide overpressure protection of the heat transport system, to mamtain sufficient reactor coolant mvenlory during and after operananal stales The system consists of the pressunzer, degasser-condenser, heat transport system safelyfrehef valves, and feed/bleed Sow paths with D,0 storage tank and feed pump... [Pg.170]

Primary circuit pressure control 1 HT pressunzer with steam-bleed valves 2 Feed and bleed system 3 Automatic liquid rehef valves 4 Mam steam safety valves A Systems 1 and 2 provide primary circuit pressure control Systems 3 and 4 prevent overpressure and provide rapid depressurization... [Pg.172]

The steam turbine with a bleed-off system, barring motor, steam sorting, stop valves and the control and protection system ... [Pg.295]

H2 Procedures used in case of loss of feedwater ARE-ASG (FWFCS (feed water flow control system) -AFWS (Auxiliary feedwater system). Residual heat is extracted using pressurizer relief valves and start up of safety injection and containment spray systems (feed and bleed process). [Pg.127]

The FOFS is at present installed in the distributor 4 of the waste water treatment plant and is fed with a representative bleed stream which is taken from the unflocculated main stream of an aeration basin via a bypass. The optimal amount of flocculant is determined for this ble stream every 15 min. In the long term, it is planned to connect the flocculation sensor to the process control system of the waste water treatment plant. After a proportional transmission control factor has been determined for the process and plant, it will be possible to control the... [Pg.173]

A.ll. If the pressurizer, if provided, can be isolated from the RCS in certain operating conditions (i.e. during warmup or cooldown), the pressure and inventory control system should include alternative means of controlling the pressure and inventory in the RCS, such as a set of automatically controlled feed and bleed valves. In this case, the pressurizer should have an independent safety and/or rehef device. [Pg.55]

A vacuum condenser has vacuum equipment (such as steam jets) pulling the noncondensibles out of the cold end of the unit. A system handling flammable substances has a control valve between the condenser and Jets (an air bleed is used to control nonflammable systems). The control method involves derating part of the tube surface by blajiketing it with noncondensibles that exhibit poor... [Pg.291]

The air bleed is u.sed to maintain a constant condition. However, a control valve may be used instead. Control or hand valves in the lower pressure vapor lines to an ejector are not recommended, as they must be paid for in system pressure drop and ejector udlity requirements. [Pg.363]

Figure 6-32 illustrates ejector systems with large condensable loads which can be at least partially handled in the precondenser. Controls are used to maintain constant suction pressure at varying loads (air bleed), or to reduce the required cooling water at low process loads or low water temperatures [2]. The cooler W ater must not be throttled below the minimum (usually 30%-50% of maximum) for proper contact in the condenser. It may be controlled by tailwater temperature, or by the absolute pressure. [Pg.379]

The abciximab in Acute Ischemic Stroke trial was a randomized, placebo-controlled dose-escalation study to examine the safety of abciximab in acute stroke. It randomized 74 patients within 24 hours of stroke onset to receive one of four doses of abciximab (by bolus with or without additional infusion, 54 patients) or placebo (20 patients). The median baseline National Institute of Health Stroke Scale (NIHSS) score was 15. The rates of asymptomatic ICH were 19% in the intervention group compared to 5% in the placebo group p = 0.07). Most (9 of 11) of the asymptomatic ICH patients had more severe stroke (NIHSS >14). No cases of symptomatic ICH or major systemic bleeding occurred. There was a trend toward a lower rate of stroke recurrence (2% vs. 5%) and a higher rate of functional recovery at 3 months in the group treated with abciximab than with placebo. [Pg.146]


See other pages where Bleed control systems is mentioned: [Pg.9]    [Pg.355]    [Pg.355]    [Pg.9]    [Pg.355]    [Pg.355]    [Pg.99]    [Pg.2517]    [Pg.417]    [Pg.305]    [Pg.99]    [Pg.352]    [Pg.210]    [Pg.2272]    [Pg.165]    [Pg.225]    [Pg.612]    [Pg.2521]    [Pg.347]    [Pg.224]    [Pg.26]    [Pg.3084]    [Pg.252]    [Pg.469]    [Pg.85]    [Pg.220]    [Pg.40]    [Pg.198]    [Pg.79]    [Pg.87]    [Pg.89]    [Pg.465]    [Pg.372]    [Pg.503]    [Pg.127]    [Pg.494]    [Pg.190]    [Pg.500]   
See also in sourсe #XX -- [ Pg.8 , Pg.355 ]




SEARCH



Bleed

Bleeding

Bleeds

© 2024 chempedia.info