Under the conditions that result in the best gradient in the preliminary experiments (step 1), one should perform a run overnight using the six columns. [Pg.40]

Once the retention models have been established by the procedures described above, no further experiments are conducted. The software automatically generates tens of thousands of linear and multi-step gradient profiles in a very short time. It predicts the retention of compounds for each gradient profile generated, evaluates the predicted separation using an optimization function, and searches for the best gradient profile using a super-fast Monte Carlo optimization method [5]. [Pg.598]

Traditional PAHs separations by reverse phase (RP)-HPLC is conducted using gradient elution, mainly with acetonitrile water mixtures and sometimes with methanokwater mixtnres. RP-HPLC on chemically bonded Cig phases has been widely used in the environmental analysis of PAHs. Up to date, a wide variety of brands of HPLC columns is available for PAHs determination. Packed columns are rarely used in contemporary GC methods for PAHs, being practically 100% of applications carried out with capillary columns. Many commercial brands of GC and HPLC include in their web pages information related to best columns to work with in a specific application, advices to optimize the best gradient elution, and even suggestions for troubleshooting. [Pg.502]

This algorithm alternates between the electronic structure problem and the nuclear motion It turns out that to generate an accurate nuclear trajectory using this decoupled algoritlun th electrons must be fuUy relaxed to the ground state at each iteration, in contrast to Ihe Car-Pairinello approach, where some error is tolerated. This need for very accurate basis se coefficients means that the minimum in the space of the coefficients must be located ver accurately, which can be computationally very expensive. However, conjugate gradient rninimisation is found to be an effective way to find this minimum, especially if informatioi from previous steps is incorporated [Payne et cd. 1992]. This reduces the number of minimi sation steps required to locate accurately the best set of basis set coefficients. [Pg.635]

Using the original Hc2/r values, recalculate M using the various refractive index gradients. On the basis of self-consistency, estimate the molecular weight of this polymer and select the best value of dn/dc2 in each solvent. Criticize or defend the following proposition Since the extension of the Debye theory to large particles requires that the difference between n for solute and solvent be small, this difference should routinely be minimized for best results. [Pg.718]

This equation, although originating from the plate theory, must again be considered as largely empirical when employed for TLC. This is because, in its derivation, the distribution coefficient of the solute between the two phases is considered constant throughout the development process. In practice, due to the nature of the development as already discussed for TLC, the distribution coefficient does not remain constant and, thus, the expression for column efficiency must be considered, at best, only approximate. The same errors would be involved if the equation was used to calculate the efficiency of a GC column when the solute was eluted by temperature programming or in LC where the solute was eluted by gradient elution. If the solute could be eluted by a pure solvent such as n-heptane on a plate that had been presaturated with the solvent vapor, then the distribution coefficient would remain sensibly constant over the development process. Under such circumstances the efficiency value would be more accurate and more likely to represent a true plate efficiency. [Pg.451]

The relative motion of materials points in a solid body in finite strain is best represented by a deformation gradient having components... [Pg.22]

Remarks Moderate selectivity Moderate separation speed Narrow mobile-phase selection Fow selectivity High-speed separation Most generous mobile-phase selection Fow selectivity High-speed separation Generous mobile-phase selection Best for high MW polymers Thermal gradient may be programmed for broad MW separation... [Pg.609]

The gradients of H, Na, and other cations and anions established by ATPases and other energy sources can be used for secondary active transport of various substrates. The best-understood systems use Na or gradients to transport amino acids and sugars in certain cells. Many of these systems operate as symports, with the ion and the transported amino acid or sugar moving in the same direction (that is, into the cell). In antiport processes, the ion and the other transported species move in opposite directions. (For example, the anion transporter of erythrocytes is an antiport.) Proton symport proteins are used by E. coU and other bacteria to accumulate lactose, arabinose, ribose, and a variety of amino acids. E. coli also possesses Na -symport systems for melibiose as well as for glutamate and other amino acids. [Pg.311]

Another example is the determination of bentazone in aqueous samples. Bentazone is a common medium-polar pesticide, and is an acidic compound which co-elutes with humic and/or fulvic acids. In this application, two additional boundary conditions are important. Eirst, the pH of the M-1 mobile phase should be as low as possible for processing large sample volumes, with a pH of 2.3 being about the best that one can achieve when working with alkyl-modified silicas. Secondly, modifier gradients should be avoided in order to prevent interferences caused by the continuous release of humic and/or fulvic acids from the column during the gradient (46). [Pg.346]

The methanol gradient from 50 to 60% releases quite a lot of interfering components. Omitting the step gradient does not provide enough selectivity and so the best conditions were obtained with a pH gradient. The experimental conditions are shown in Table 13.1. [Pg.346]

The pseudopotential density-functional technique is used to calculate total energies, forces on atoms and stress tensors as described in Ref. 13 and implemented in the computer code CASTEP. CASTEP uses a plane-wave basis set to expand wave-functions and a preconditioned conjugate gradient scheme to solve the density-functional theory (DFT) equations iteratively. Brillouin zone integration is carried out via the special points scheme by Monkhorst and Pack. The nonlocal pseudopotentials in Kleynman-Bylander form were optimized in order to achieve the best convergence with respect to the basis set size. 5... [Pg.20]


See other pages where Best gradient is mentioned: [Pg.174]    [Pg.84]    [Pg.111]    [Pg.55]    [Pg.330]    [Pg.343]    [Pg.167]    [Pg.167]    [Pg.174]    [Pg.84]    [Pg.111]    [Pg.55]    [Pg.330]    [Pg.343]    [Pg.167]    [Pg.167]    [Pg.8]    [Pg.236]    [Pg.282]    [Pg.285]    [Pg.502]    [Pg.71]    [Pg.78]    [Pg.110]    [Pg.88]    [Pg.209]    [Pg.238]    [Pg.745]    [Pg.1531]    [Pg.241]    [Pg.88]    [Pg.503]    [Pg.512]    [Pg.81]    [Pg.82]    [Pg.286]    [Pg.145]    [Pg.17]    [Pg.284]    [Pg.408]    [Pg.316]    [Pg.119]    [Pg.33]    [Pg.192]    [Pg.335]    [Pg.342]   