Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Barrier height comparisons

Given the simplicity of the models employed, only comparisons of relative (and not absolute) barrier heights are meaningful. [Pg.90]

Comparison of Barrier Heights (BH) in kcal mol for the Proton Transfer in Malonaldehyde Computed by Different Quantum Chemical Methods... [Pg.125]

Fig. 9 OMT bands for NiOEP, associated with transient reduction (1.78 V) and transient oxidation (—1.18 V). Data obtained from a single molecule in a UHV STM. The ultraviolet photoelectron spectrum is also shown, with the energy origin shifted (by the work function of the sample, as discussed in [25]) in order to allow direct comparison. The highest occupied molecular orbital, n, and the lowest unoccupied molecular orbital, %, are shown at their correct energy, relative to the Fermi level of the substrate. As in previous diagrams,

Fig. 9 OMT bands for NiOEP, associated with transient reduction (1.78 V) and transient oxidation (—1.18 V). Data obtained from a single molecule in a UHV STM. The ultraviolet photoelectron spectrum is also shown, with the energy origin shifted (by the work function of the sample, as discussed in [25]) in order to allow direct comparison. The highest occupied molecular orbital, n, and the lowest unoccupied molecular orbital, %, are shown at their correct energy, relative to the Fermi level of the substrate. As in previous diagrams, <P is the barrier height in eV, and Tb is the applied sample bias. This simplified model has a thin layer of porphyrin (NiOEP) on the substrate and a relatively large vacuum gap between the porphyrin and the STM tip. (Reprinted with permission from [26])...
Fig. 3. Enthalpy diagram (Aif298, kcal/mol B3LYP level of DFT) for reductive elimination of methane from one isomer of (R3P)2Cl2PtCH3(H), PR3=P(CH3)3 or PH3. The dotted line refers to the P(CH3)3 system, where the relative order of barrier heights changes in comparison to the PH3 system. The diagram was drawn using the data from Refs. (132,133). Fig. 3. Enthalpy diagram (Aif298, kcal/mol B3LYP level of DFT) for reductive elimination of methane from one isomer of (R3P)2Cl2PtCH3(H), PR3=P(CH3)3 or PH3. The dotted line refers to the P(CH3)3 system, where the relative order of barrier heights changes in comparison to the PH3 system. The diagram was drawn using the data from Refs. (132,133).
FIG. 15. A comparison between the distance dependence of the tunneling barrier between a jellium tip and substrate immersed in solution versus vacuum under zero bias conditions. The apparent barrier height is derived from the WKB approximation. (From Ref. 110.)... [Pg.235]

The test set used for most comparisons in the present paper is Database/3 18), which was introduced elsewhere. It consists of 109 atomization energies (AEs), 44 forward and reverse reaction barrier heights (BHs) of 22 reactions, 13 electron affinities (EAs), and 13 ionization potentials (IPs). There are a total of 513 bonds among the 109 molecules used for AEs, where double or triple bonds are only counted as a single bond. Note that all ionization potentials and electron affinities are adiabatic (not vertical), i.e., the geometry is optimized for the ions... [Pg.157]

The first ab initio MO calculation of the reaction between MeLi and H2C=0 was carried out mostly at the HF/3-21G level of theory . The comparison of the reaction profiles for the monomer and dimer species revealed that the first complex formation was less exothermic and the barrier for the addition step was lower for the dimer reaction, but the overall barrier height was similar for the two systems. The overall reaction was more exothermic for the dimer reaction. [Pg.919]

Fig. 8.8. Variation of the measured apparent barrier height with distance. Circles are data points. The solid curve is derived from Eq. (8.26). The dashed curve is the actual gap displacement as a function of the measured -piezo displacement. The dotted curve, the fictitious gap displacement in the absence of force, is included for comparison. (Reproduced from Chen and Hamers, 1991a, with permission.)... Fig. 8.8. Variation of the measured apparent barrier height with distance. Circles are data points. The solid curve is derived from Eq. (8.26). The dashed curve is the actual gap displacement as a function of the measured -piezo displacement. The dotted curve, the fictitious gap displacement in the absence of force, is included for comparison. (Reproduced from Chen and Hamers, 1991a, with permission.)...
A study of the effeets of space and time dependent frietion was presented in Ref 68. One finds a substantial reduction of the rate relative to the parabolic barrier estimate when the friction is stronger in the well than at the barrier. In all eases, the effeets beeome smaller as the redueed barrier height beeomes larger. Comparison with moleeular dynamics simulations shows that the optimal planar dividing surfaee estimate for the rate is usually quite aeeurate. [Pg.14]

For molecular dynamics (MD) simulations to accurately reflect chain motions and conformational changes at various temperatures, the rotational barriers must be correct whether they arise from an explicit dihedral term, vdW interactions, or both. Barriers that are too low will allow disorder to occur at simulated temperatures far below experimental temperatures at which transitions and disorders in PTFE are observed. The validity of the barrier heights, especially the one at trans, obtained from the MOPAC AMI calculations and derived force field parameters above was called into question upon comparison to high level ab initio calculations on perfluorobutane (PFB), perfluoropentane (PFP), and... [Pg.176]

In the standard overdamped version of the Kramers problem, the escape of a particle subject to a Gaussian white noise over a potential barrier is considered in the limit of low diffusivity—that is, where the barrier height AV is large in comparison to the diffusion constant K [14] (compare Fig.6). Then, the probability current over the potential barrier top near xmax is small, and the time change of the pdf is equally small. In this quasi-stationary situation, the probability current is approximately position independent. The temporal decay of the probability to find the particle within the potential well is then given by the exponential function [14, 22]... [Pg.246]

Table V. Comparison of the Barrier Height or Flatband Voltage Change for Different Sensor Structures... Table V. Comparison of the Barrier Height or Flatband Voltage Change for Different Sensor Structures...

See other pages where Barrier height comparisons is mentioned: [Pg.32]    [Pg.129]    [Pg.124]    [Pg.128]    [Pg.452]    [Pg.60]    [Pg.437]    [Pg.158]    [Pg.417]    [Pg.486]    [Pg.56]    [Pg.65]    [Pg.242]    [Pg.244]    [Pg.235]    [Pg.207]    [Pg.155]    [Pg.58]    [Pg.195]    [Pg.261]    [Pg.264]    [Pg.58]    [Pg.202]    [Pg.267]    [Pg.300]    [Pg.370]    [Pg.2510]    [Pg.199]    [Pg.261]    [Pg.264]    [Pg.163]    [Pg.193]    [Pg.209]    [Pg.336]    [Pg.443]   


SEARCH



Barrier heights

© 2024 chempedia.info