Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Balancing standards

Important balancing techniques and concepts to be discussed in the sections to follow include in-place balancing, single-plane versus two-plane balancing, precision balancing, techniques that make use of a phase shift, and balancing standards. [Pg.939]

The ISO has published standards for acceptable limits for residual imbalance in various classifications of rotor assemblies. Balancing standards are given in oz-ins or lb-ins per pound of rotor weight or the equivalent in metric units (g-mm/kg). The oz-ins are for each correction plane for which the imbalance is measured and corrected. [Pg.940]

Caution must be exercised when using balancing standards. The recommended levels are for residual imbalance, which is defined as imbalance of any kind that remains after balancing. [Pg.940]

Figure 55.1 Balancing standards residual imbalance per unit rotor weight (Ref. 5)... Figure 55.1 Balancing standards residual imbalance per unit rotor weight (Ref. 5)...
Most balancing standards are based on a residual imbalance and do not include multi-plane imbalance. If they are approximately 180° to each other, they form a couple. If the distance between the planes is small, the resulting couple is small if the distance is large, the couple is large. A couple creates considerably more vibration than when the two residual imbalances are in-phase. Unfortunately, there is nothing in the balancing standards that considers this. [Pg.941]

Assure that pesticide tolerances are safe for vulnerable populations, in particular, infants, children and the elderly, based on a reasonable certainty of no harm health-based standard, instead of the previous cost-benefit balancing standard ... [Pg.266]

Calculate <%° values for the following cells. Which reactions are spontaneous as written, under standard conditions Balance the reactions that are not already balanced. Standard reduction potentials are found in Table 11.1. [Pg.501]

BCAA products have not universally improved nitrogen balance. Standard amino acid mixtures can be used successfully without worsening encephalopathy. Studies examining improvement in encephalopathy or mortality rates with use of these modified amino acids have yielded conflicting results. This, coupled with the increased cost of these products, has led most clinicians to reserve these products for patients with severe encephalopathy who decompensate on standard amino acids despite continued lactulose-neomycin therapy. [Pg.2645]

Keter V (2007) Work Life Balance. Standard Note SN/BT/348. House of Commons Library, London... [Pg.342]

Standardization and innovation and in doing so under constraint — economic, political, physical, institutional, etc. Institutions vary and the vitality that comes from balanced standardization and diversity needs to be systemically embraced. But with any change, core legacy, contemporary engineering fundamentals, and the problem conceptualization and solving abilities of mechanical engineering graduates must be retained. [Pg.141]

Shimadzu offers the TGA-50/50H with 1 g sample capacity and the TGA-51/51H with 10 g sample capacity. All systems have bottom-loading balances. Standard systems heat from ambient to 1000 °C, while the H systems heat from ambient to 1500 °C. All four systems can heat from 0.002 to 100°C/min and support vacuum to 10 torr. The TGA-50 series has smaller volume and... [Pg.310]

The required equipment to synthesize them includes precision laboratory balances, standard laboratory equipment, and equipment for woridng under shielding gas. During the preparation and handling of the polymerization solutions, tire use of a glove box is recommended, since the reaction mechanism is strongly influenced by the presence of oxygen. [Pg.105]


See other pages where Balancing standards is mentioned: [Pg.934]    [Pg.940]    [Pg.940]    [Pg.411]    [Pg.633]    [Pg.68]   
See also in sourсe #XX -- [ Pg.68 ]




SEARCH



© 2024 chempedia.info