Auxiliary flows

Chlorine Plant Auxiliaries. Flow diagrams for the three electrolytic chlor—alkali processes are given in Figures 28 and 29. Although they differ somewhat in operation, auxiUary processes such as brine purification and chlorine recovery are common to each. [Pg.500]

Fuller claims that an auxiliary cupboard has better performance than an ordinary cupboard, if properly designed and used. The auxiliary flow rate should be 50% to 75% of the total exhaust flow from the cupboard. Below 50% there is no beneficial effect and above 75% the auxiliary air will aspirate contaminants out of the cupboard. The auxiliary air should enter the hood through the upper one-half to two-thirds of the opening. This should fill the volume between the cupboard operator and the opening and assist in the containment. The auxiliary air should be distributed uniformly across the length of the cupboard for a vertically sliding sash or above only the open sash of a cupboard with a horizontally sliding sash. It should also have a temperature within 1.5 °C of the room temperature and have a constant flow rate without pulsations. [Pg.996]

According to Mitchell" the auxiliary flow rate should be between 20% and 40% of the total exhaust flow rate from the cupboard below 20% results in only small improvements and above 40%, leakage rises quite fast with in creasing flow rate. [Pg.996]

In this method the soil sample is dried overnight at 85 °C and ground into an homogeneous mixture. A 1 g soil sample is placed into a beaker and 10 ml of concentrated nitric acid added. The solution is heated to dryness and 5 ml of concentrated nitric acid is added. The uranium is redissolved in 5 ml of 8 N nitric acid and diluted to 25 ml with distilled water. The inductively coupled plasma mass spectrometry system used was an ELAN Model 250. The ion source consists of a modified plasma Thermal Model 2500 control box. The forward power was set at 1200 W with the plasma flow, auxiliary flow and nebuliser pressure set at 131/min, 1.0l/min and 0.27 MPa, respectively. The focusing lenses B, El, P and S2 are set at +5.3 V, -12.5 V, -18.0 V and -7.6 V, respectively. The m/z238 ion was monitored for two sec-... [Pg.58]

Detector MS, Sciex Model API III triple quadrupole, nebulizer probe 500°, nebulizing gas 80 psi, auxiliary flow 2 L/min, corona discharge needle -1-3 p,A, 0.1143 mm orifice, orifice 40 V, collision gas argon... [Pg.1284]

Auxiliary flow sheets cover the auxiliary process requirements such as steam, water, fuel, air, and other utilities. As with instrumentation, W. T. Butler, Kennecott Copper Corp., private communication, 1956,... [Pg.76]

Single-stage, batch or continuous separation steps in multiphase systems can only lead to near-complete separations when the partition (or distribution) coefficients of the components over the various phases are sufficiently different. Because of the common structural similarity of main products and contaminants, this is usually not the case. The key parameter is the so-called separation factor S (Fig. 3). Assuming thermodynamic equilibrium between outlet flows of a single equilibrium stage, the separation factor S relates performance to the ratio of auxiliary flow (V) and feed flow (L) and the distribution coefficient of the... [Pg.79]

Figure 5 (A) Schematic description of a multidimensional gas chromatography arrangement, where a switching system or valve (V) is located between the two columns. The process of switching the flow between and or to the monitor detector (det M) is not shown. The auxiliary flow (aux) provides flow to the system to assist in the switching process, and/or to provide make-up flow into the column, which Is not receiving flow from the precolumn. is normally a column of regular dimensions, and may incorporate a cryofocusing step at the head of the column. (B) The comprehensive two-dimensional gas chromatography arrangement essentially only requires a mechanism for modulation between the two columns, which provides a series of narrow peaks (at least four normally) to for each D peak. The modulator (M) is shown near the column connection. is normally a short, fast elution column. Figure 5 (A) Schematic description of a multidimensional gas chromatography arrangement, where a switching system or valve (V) is located between the two columns. The process of switching the flow between and or to the monitor detector (det M) is not shown. The auxiliary flow (aux) provides flow to the system to assist in the switching process, and/or to provide make-up flow into the column, which Is not receiving flow from the precolumn. is normally a column of regular dimensions, and may incorporate a cryofocusing step at the head of the column. (B) The comprehensive two-dimensional gas chromatography arrangement essentially only requires a mechanism for modulation between the two columns, which provides a series of narrow peaks (at least four normally) to for each D peak. The modulator (M) is shown near the column connection. is normally a short, fast elution column.
Liquid samples are introduced into the vaporization chamber by syringe through a septum or airlock. An auxiliary flow of gas is used to purge septum bleed products and contaminants away from the vaporization chamber. Appropriate column loads are usually achieved by injecting sample volumes of 0.2-2.0 pi with split ratios between 1 10 and 1 1000. [Pg.1869]

Nowadays, atomic absorption spectrometry (AAS) systems are comparatively inexpensive element selective detectors, and some of the instruments also show multi(few)-element capability. There are flame (F AAS), cold vapor (CV AAS), hydride-generating (HG AAS), and graphite furnace (GF-AAS) systems. However, the use of AAS-based detectors for on-line speciation analysis is problematic. F AAS is usually not sensitive enough for speciation analysis at "normal" environmental or physiological concentrations and sample intake is high (4—5 ml/min), which complicates on-line hyphenations with LC an auxiliary flow is necessary. CV AAS and HG AAS use selective derivatization for matrix separation and increased sensitivity for the derivatized species. But, the detector response is species dependent and interferences can be a problem. GF AAS requires only a few microliters of sample and provides low detection limits, between 0.1 and 5 gg/1. Matrix interferences are widely eliminated by Zeeman correction and matrix modifiers nevertheless, quantification errors were reported as atomization temperature does not exceed 2900°C. The most critical problem in respect to speciation analysis is the discontinuous measiuement because of the temperature program operation employed, which takes a few minutes. Therefore, GF AAS is unsuitable for on-line hyphenations as chromatograms carmot be monitored with sufficient resolution. [Pg.643]

The operating temperature and component dimensions were optimized to achieve the plant net thermal efficiency of 38.2%. The feedwater pumps are shared by the two identical steam generation systems, while each one is equipped with its own main and auxiliary flow control valves, as shown in Fig. XX-11. This feature secures an optimum use of plant resources and introduces better plant economy and operational flexibility. [Pg.572]

We describe two bistable systems and the corresponding oscillators. The first system consists of H2O2 and KI in a dilute H SO medium. An auxiliary flow of iodate lOi, at elevated temperature only, causes oscillations to take place. The second system consists of (NH3)2 S O and KI in H2S0 medium,is bistable at T > 45°C, and it oscillates in the presence of a flow of oxalic acid (C00H)2. [Pg.69]

Switch the valve to the RESET position and adjust the auxiliary flow controller to give a flow of 10 mL/min at the Detector A (FID) exit. [Pg.925]


See other pages where Auxiliary flows is mentioned: [Pg.127]    [Pg.665]    [Pg.180]    [Pg.990]    [Pg.338]    [Pg.986]    [Pg.334]    [Pg.183]    [Pg.77]    [Pg.83]    [Pg.485]    [Pg.300]    [Pg.286]    [Pg.80]    [Pg.82]    [Pg.268]    [Pg.141]    [Pg.542]    [Pg.11]    [Pg.31]    [Pg.914]    [Pg.1226]    [Pg.545]    [Pg.21]    [Pg.2]    [Pg.7]    [Pg.924]   
See also in sourсe #XX -- [ Pg.31 ]




SEARCH



Auxiliary gas flow

Flow sheets, auxiliary process

Flow sheets, auxiliary process equipment

Pressurized water reactors auxiliary flows