Attenuation of X-rays

X-rays are removed from a collimated beam either by scattering out of the beam or by being absorbed. The process is quantized and probabilistic in nature. An X-ray beam can be considered as a flow of discrete photon particles each having a specific [Pg.92]

This leads naturally to the concept of X-ray attenuation, defined as the natural logarithm of the transmitted intensity fraction  [Pg.93]

For X-rays from a continuous energy spectrum, p E), passing through a series of materials indexed by i, the formula for attenuation generahzes to [Pg.93]

Note that the order in which the series of materials occurs is immaterial the contribution of each is weighted according to its areal density and mass attenuation coefficient. [Pg.94]


Methyl chloride, determination by x-ray absorptiometry, 84 Mica, attenuation of x-rays by, 45 Microanalysis, use of x-rays in histo-chemical and eytochemical, 296-305... [Pg.348]

Traditional radiographic methods use two-dimensional film to record the attenuation of X-rays passing through a three-dimensional object. The... [Pg.1092]

Special formulations have been developed to visualize the gastrointestinal tract (see below). Magnevist has also been applied succesfully as an X-ray contrast agent in patients who were allergic to iodine because of the attenuation of X-rays by the gadolinium ion [14]. [Pg.6]

The extension of XRD from small samples to extended objects requires two main modifications of Eq. 10 to account for the self-attenuation of X-rays within the object and also to describe the component of scatter signal that suffers more than one interaction within the object. [Pg.217]

Because of the attenuation of x-rays by air, the x-rays interacting with the cloth would convey three-dimensional information. Also because of the emission of x-rays from many point sources, the image is not in sharp focus. Rather the image is diffuse, and it can best be observed from a distance because the eye integrates the intensity of light so that the image then makes sense. [Pg.435]

Soft X-rays E < 1 keV) are rapidly absorbed by matter and have escape depths from a solid surface only a few pm corresponding to approximately the top thousand atomic layers of a sample. Therefore changes in peak profile, satellite peaks, etc., which are informative of chemical effects, can be used to infer chemical changes in sample surfaces. Since the air attenuation of X-ray becomes quite significant at low energies, the entire sample chamber is placed in vacuum. [Pg.22]

Attenuation of x rays by windows around the sampie and extra background scatter ... [Pg.8110]

FIGURE 7 Linear attenuation coefficient of water and contribution of each interaction to the attenuation of X rays as a function of the energy. [Pg.534]

X-ray thickness measurement The measurement of the thickness (mass per unit area) by the attenuation of X-rays passing through the material. See also Thickness. [Pg.733]


See other pages where Attenuation of X-rays is mentioned: [Pg.443]    [Pg.577]    [Pg.49]    [Pg.340]    [Pg.340]    [Pg.349]    [Pg.352]    [Pg.355]    [Pg.336]    [Pg.290]    [Pg.89]    [Pg.92]    [Pg.203]    [Pg.114]    [Pg.1213]    [Pg.1215]    [Pg.159]    [Pg.1405]    [Pg.8]    [Pg.4608]    [Pg.5141]    [Pg.5141]    [Pg.5142]    [Pg.5173]    [Pg.5178]    [Pg.259]    [Pg.344]    [Pg.149]    [Pg.173]    [Pg.215]   