Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Atom counting accelerator mass

Principal characteristics of small sample liquid scintillation counting (lsc), gas proportional low-level counting (11c) and atom counting by accelerator mass spectrometry (AMS) are summarized in Table 1, and systems we have used are shown in figure 1. The most important differences (apart from cost and availability)... [Pg.164]

The ratio A/A0 is measured either by P" counting or with the tandem accelerator mass spectrometer (TAMS) in which direct atom counting is used. [Pg.308]

Accelerator mass spectrometry (AMS) extends the capabilities of atom-counting using conventional mass spectrometry, by removing whole-mass molecular interferences without the need for a mass resolution very much better than the mass difference between the atom and its molecular isobar. This technique has been used with great success for the routine measurement of C, Be, " Al, C1 and, recently, (see Table 5.15). Analysis of " C by AMS can, for example, generate dates with a precision that is at least equal to the best conventional beta-particle-counting facility. In many cases, where small sample analysis is required, the AMS method has proved superior (Benkens, 1990). A complete description of AMS can be found in review articles (Litherland et al., 1987 Elmore and Philips, 1978) or recent conference publications. The application of AMS to measurement has been discussed in detail in Kilins et al. (1992). [Pg.223]

Accelerator Mass Spectrometry (AMS) was developed to overcome the fundamental limitations of both the decay-counting as well as conventional mass spectrometry. AMS method takes much less time, e.g., 10,000 atoms of 14c... [Pg.296]

Accelerator mass spectrometry (Fig. 21) is de-.signed for the most precise atom counting of cos-... [Pg.602]

An important property of the MOT is the ability to catch atoms whose optical frequencies are shifted from the laser frequency by only a few natural linewidths. This property has been applied for ultrasensitive isotope trace analysis. Chen et al. (1999) developed the technique in order to detect a counted number of atoms of the radioactive isotopes Kr and Kr, with abundances 10 and 10 relative to the stable isotope Kr. The technique was called atom trap trace analysis (ATTA). At present, only the technique of accelerator mass spectrometry (AMS) has a detection sensitivity comparable to that of ATTA. Unlike the AMS technique based on a high-power cyclotron, the ATTA technique is much simpler and does not require a special operational environment. In the experiments by Chen et al. (1999), krypton gas was injected into a DC discharge volume, where the atoms were excited to a metastable level. 2D transverse laser cooling was used to collimate the atomic beam, and the Zee-man slowing technique was used to load the atoms into the MOT. With the specific laser frequency chosen for trapping the Kr or Kr isotope, only the chosen isotope could be trapped by the MOT. The experiment was able to detect a single trapped atom of an isotope, which remained in the MOT for about a second. [Pg.110]

Plate 22 Radiocarbon dating. View of a linear accelerator used as part of an accelerator mass spectrometer (AMS). This device is capable of counting the relatively few carbon-14 atoms in a radioactive sample. The proportion of carbon-14 to carbon-12 atoms in the sample may be used to determine the radiocarbon age of an organic object. This is then adjusted by various corrections to give the true age. See Isotope Ratio Studies Using Mass Spectrometry. Reproduced with permission from Science Photo Library. [Pg.1277]

In Secondary Ion Mass Spectrometry (SIMS), a solid specimen, placed in a vacuum, is bombarded with a narrow beam of ions, called primary ions, that are suffi-ciendy energedc to cause ejection (sputtering) of atoms and small clusters of atoms from the bombarded region. Some of the atoms and atomic clusters are ejected as ions, called secondary ions. The secondary ions are subsequently accelerated into a mass spectrometer, where they are separated according to their mass-to-charge ratio and counted. The relative quantities of the measured secondary ions are converted to concentrations, by comparison with standards, to reveal the composition and trace impurity content of the specimen as a function of sputtering dme (depth). [Pg.40]

In the technique developed by Willard Libby in Chicago in the late 1940s, the proportion of carbon-14 in a sample is determined by monitoring the (1 radiation from C02 obtained by burning the sample. This procedure is illustrated in Example 17.4. In the modern version of the technique, which requires only a few milligrams of sample, the carbon atoms are converted into C ions by bombardment of the sample with cesium atoms. The C ions are then accelerated with electric fields, and the carbon isotopes are separated and counted with a mass spectrometer (Fig. 17.19). [Pg.832]

Thinking Critically The K-Ar data for this experiment were obtained using a mass spectrometer. In this process, a small sample is heated with a laser until its constituent atoms vaporize and become ionized. A voltage is then applied that accelerates the charged ions towards a detector. The lightest ions reach the detector first, and the numbers of ions of each mass are identified and counted. There are a number of practical concerns that researchers must address in order to be confident that the measurements truly yield an accurate age for the object. List and explain a few possible concerns. [Pg.195]


See other pages where Atom counting accelerator mass is mentioned: [Pg.364]    [Pg.307]    [Pg.499]    [Pg.62]    [Pg.239]    [Pg.191]    [Pg.474]    [Pg.1415]    [Pg.84]    [Pg.272]    [Pg.438]    [Pg.2157]    [Pg.2715]    [Pg.3194]    [Pg.215]    [Pg.159]    [Pg.434]    [Pg.238]    [Pg.755]    [Pg.392]    [Pg.368]    [Pg.1545]    [Pg.238]    [Pg.528]    [Pg.891]    [Pg.2403]    [Pg.1771]    [Pg.295]    [Pg.308]    [Pg.312]    [Pg.259]    [Pg.420]    [Pg.708]    [Pg.224]    [Pg.296]    [Pg.240]    [Pg.29]    [Pg.287]    [Pg.48]    [Pg.85]   


SEARCH



Atom , atomic mass

Atom Count

Atomic mass

Mass accelerator

© 2024 chempedia.info