Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Aqueous fluid control materials

Traditionally, QC materials can be commercial blood-based fluids or aqueous fluids. Alternatively, independent standard buffers can be used for pH control and tonometered whole blood for PCO2 and PO2 control. [Pg.1011]

A derivatized hydroxyethylcellulose polymer gel exhibited excellent fluid-loss control over a wide range of conditions in most common completion fluids. This particular grated gel was compatible with the formation material and caused little or no damage to original permeability [1341]. Detailed measurements of fluid loss, injection, and regained permeability were taken to determine the polymer particulate s effectiveness in controlling fluid loss and to assess its ease of removal. Hydroxyethylcellulose can be etherified or esterified with long chain alcohols or esters. An ether bond is more stable in aqueous solution than is an ester bond [96]. [Pg.40]

For materials applications, the chemical shifts of methanol and ethylene glycol can be monitored in the liquid state to follow temperature [Hawl]. The most sensitive ehemical shift is the Co resonance of aqueous Co(CN)e with a sensitivity of 0.05 K at 7 T and 0.2 K at 2T [Dorl]. Furthermore, dibromomethane dissolved in a liquid crystal is a temperature sensitive NMR compound [Hed 1 ], and known phase-transition temperatures can be exploited to calibrate the temperature control unit [Hawl J. In temperature imaging of fluids, temperature can be determined from the temperature dependence of the selfdiffusion coefficient but convective motion may arise in temperature gradients [Hedl]. In the solid state, the longitudinal relaxation time of quadrupolar nuclei like Br is a temperature sensitive parameter [Suil, Sui2]. In elastomers, both T2 and Ti depend on temperature (Fig. 7.1.13). In filled SBR, T2 is the more sensitive parameter with a temperature coefficient of about 30 xs/K [Haul]. [Pg.260]


See other pages where Aqueous fluid control materials is mentioned: [Pg.1012]    [Pg.1012]    [Pg.1012]    [Pg.101]    [Pg.331]    [Pg.1867]    [Pg.597]    [Pg.1929]    [Pg.373]    [Pg.181]    [Pg.160]    [Pg.304]    [Pg.239]    [Pg.17]    [Pg.423]    [Pg.244]    [Pg.122]    [Pg.445]    [Pg.453]    [Pg.117]    [Pg.383]    [Pg.772]    [Pg.373]    [Pg.160]    [Pg.74]    [Pg.605]    [Pg.2227]    [Pg.46]    [Pg.2172]    [Pg.36]    [Pg.1263]    [Pg.106]    [Pg.230]    [Pg.51]    [Pg.4]    [Pg.107]    [Pg.574]    [Pg.628]    [Pg.164]    [Pg.61]    [Pg.154]    [Pg.467]    [Pg.2156]    [Pg.35]    [Pg.35]    [Pg.284]    [Pg.283]    [Pg.74]   
See also in sourсe #XX -- [ Pg.1012 ]




SEARCH



Control fluids

Control materials

Controllable fluid

© 2024 chempedia.info