Analytical Methods. Molecular weights were measured by summing the areas obtained by simulated distillation using gas chromatography, calibrated by injecting a series of standard aromatic compounds. [Pg.77]

Biomolecule detectors incorporate a biorecognition device capable of selectively recognizing the analyte of interest in connection with a signal transducer and a suitable output device. Transduction methods include a variety of optical (surface plasmon resonance [SPR], fluorescence), electrochemical (voltammetry, impedance, field effect), mechanical (cantilever, surface probe microscopy), and mass-based systems (quartz crystal microgravimetry [QCM], mass spectrometry). Selection of the appropriate transduction system is partially determined by the nature of information sought (quantitative or qualitative), the analyte (concentration, molecular weight), the sample size, and assay timeline. [Pg.435]

Scale of Operation Coulometric methods of analysis can be used to analyze small absolute amounts of analyte. In controlled-current coulometry, for example, the moles of analyte consumed during an exhaustive electrolysis is given by equation 11.32. An electrolysis carried out with a constant current of 100 pA for 100 s, therefore, consumes only 1 X 10 mol of analyte if = 1. For an analyte with a molecular weight of 100 g/mol, 1 X 10 mol corresponds to only 10 pg. The concentration of analyte in the electrochemical cell, however, must be sufficient to allow an accurate determination of the end point. When using visual end points, coulometric titrations require solution concentrations greater than 10 M and, as with conventional titrations, are limited to major and minor analytes. A coulometric titration to a preset potentiometric end point is feasible even with solution concentrations of 10 M, making possible the analysis of trace analytes. [Pg.507]

Analytical and test methods for the characterization of polyethylene and PP are also used for PB, PMP, and polymers of other higher a-olefins. The C-nmr method as well as k and Raman spectroscopic methods are all used to study the chemical stmcture and stereoregularity of polyolefin resins. In industry, polyolefin stereoregularity is usually estimated by the solvent—extraction method similar to that used for isotactic PP. Intrinsic viscosity measurements of dilute solutions in decahn and tetraHn at elevated temperatures can provide the basis for the molecular weight estimation of PB and PMP with the Mark-Houwiok equation, [rj] = KM. The constants K and d for several polyolefins are given in Table 8. [Pg.431]

There are no universally accepted wet analytical methods for the characteri2ation of quaternary ammonium compounds. The American Oil Chemists Society (AOCS) has estabhshed, however, a number of appHcable tests (180). These include sampling, color, moisture, amine value, ash, iodine value, average molecular weight, pH, and flash point. [Pg.378]

In addition to this drive to look beyond manufacturing to specifications, new analytical methods such as molecular weight distribution, Mooney relaxation, and other measures of polymer processibiHty are being explored. [Pg.549]

Nonionic surfactants, including EO-PO block copolymers, may be readily separated from anionic surfactants by a simple batch ion exchange method [21] analytical separation of EO-PO copolymers from other nonionic surfactants is possible by thin-layer chromatography (TLC) [22,23] and paper chromatography [24], and EO-PO copolymers may themselves be separated into narrow molecular weight fractions on a preparative scale by gel permeation chromatography (GPC) [25]. [Pg.768]

With this relationship for all samples was calculated from ninh This M is used for evaluating the reaction data. The ultracen rifuge (u.c measurements were carried out in a Spinco model E analytical ultracentrifuge, with 0.4% solutions in 90% formic acid containing 2.3 M KCl. By means of the sedimenta- ion diffusion equilibrium method of Scholte (13) we determine M, M and M. The buoyancy factor (1- vd = -0.086) necessary for tSe calculation of these molecular weights from ultracentrifugation data was measured by means of a PEER DMA/50 digital density meter. [Pg.141]

When optimum experimental conditions have been obtained, all of the mobile phase is removed before the analyte(s) are introduced into the mass spectrometer for ionization. As a consequence, with certain limitations, it is possible to choose the ionization method to be used to provide the analytical information required. This is in contrast to the other LC-MS interfaces which are confined to particular forms of ionization because of the way in which they work. The moving belt can therefore provide both electron and chemical ionization spectra, yielding both structural and molecular weight information. [Pg.136]

The analyst does have some choice of the ionization method to be used El, Cl and FAB are available, subject to certain limitations, and thus both molecular weight and structural information may be obtained from the analyte(s) under investigation. [Pg.139]

Matrix-assisted laser desorption ionization (MALDI) A method used for the ionization of high-molecular-weight compounds. In this approach, the analyte is crystallized with a solid matrix and then bombarded with a laser of a frequency which is absorbed by the matrix material. [Pg.307]

A further extension of the DFG S19 method was achieved when polar analytes and those unsuitable for GC were determined by LC/MS or more preferably by liquid chromatography/tandem mass spectrometry (LC/MS/MS). Triple-quadrupole MS/MS and ion trap MS" have become more affordable and acceptable in the recent past. These techniques provide multiple analyte methods by employing modes such as time segments, scan events or multiple injections. By improving the selectivity and sensitivity of detection after HPLC separation, the DFG S19 extraction and cleanup scheme can be applied to polar or high molecular weight analytes, and cleanup steps such as Si02 fractionation or even GPC become unnecessary. [Pg.57]


See other pages where Analytical methods molecular weight is mentioned: [Pg.249]    [Pg.329]    [Pg.66]    [Pg.158]    [Pg.147]    [Pg.169]    [Pg.165]    [Pg.1328]    [Pg.1136]    [Pg.33]    [Pg.537]    [Pg.298]    [Pg.379]    [Pg.363]    [Pg.366]    [Pg.446]    [Pg.501]    [Pg.241]    [Pg.241]    [Pg.100]    [Pg.117]    [Pg.174]    [Pg.71]    [Pg.532]    [Pg.536]    [Pg.681]    [Pg.578]    [Pg.18]    [Pg.241]    [Pg.596]    [Pg.281]    [Pg.46]    [Pg.109]    [Pg.134]    [Pg.171]    [Pg.984]    [Pg.317]    [Pg.204]    [Pg.1136]   