Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Amperometry determination

Amperometry Determination of cyanide in the presence of sulphide. Interference study 162... [Pg.542]

CN Mining sample Chemical Amperometry Determination in presence of S ... [Pg.3001]

Peckova K, Jandova K, Maixntaova L et al (2009) Amperometrie determination of aminobiphenyls using HPLC-ED with boron-doped diamond electrode. Electroanalysis... [Pg.251]

In potentiometry, the potential of an electrochemical cell under static conditions is used to determine an analyte s concentration. As seen in the preceding section, potentiometry is an important and frequently used quantitative method of analysis. Dynamic electrochemical methods, such as coulometry, voltammetry, and amper-ometry, in which current passes through the electrochemical cell, also are important analytical techniques. In this section we consider coulometric methods of analysis. Voltammetry and amperometry are covered in Section 1 ID. [Pg.496]

Amperometry refers to measurement of current under a constant applied voltage and under these conditions it is the concentration of the analyte which determines the magnitude of the current. Such measurements may be used to follow the change in concentration of a given ion during a titration, and thus to fix the end point this procedure is referred to as amperometric titration. [Pg.591]

HPAEC analyses were carried out to determine the oligomeric products released from various pectic substrates after depolymerization by the PL isoenzymes. Action pattern analyses for the concerted action of PL isoenzymes utilized 68% esterified pectin as substrate. One-ml reaction mixtures in a buffer system as detailed in section 2.2. comprising 0.5% (w/v) substrate and 5 U of enzyme were incubated for 30 s to 18 h, and then thermoinactivated. Samples of 750 pi were applied to a Carbopac PA-1 (Dionex) column before the carbohydrates were eluted over a period of 70 min using a gradient of 0.2 M KOH, 0.05 M K-acetate to 0.2 M KOH, 0.7 M K-acetate. Detection employed a Pulsed Electrochemical Detector (PED, Dionex) in the integrated amperometry mode according to the manufacturer s recommendations. [Pg.285]

Monitoring enzyme catalyzed reactions by voltammetry and amperometry is an extremely active area of bioelectrochemical interest. Whereas liquid chromatography provides selectivity, the use of enzymes to generate electroactive products provides specificity to electroanalytical techniques. In essence, enzymes are used as a derivatiz-ing agent to convert a nonelectroactive species into an electroactive species. Alternatively, electrochemistry has been used as a sensitive method to follow enzymatic reactions and to determine enzyme activity. Enzyme-linked immunoassays with electrochemical detection have been reported to provide even greater specificity and sensitivity than other enzyme linked electrochemical techniques. [Pg.28]

Again for the titration of Ce(IV) with Fe(II) we shall now consider constant-potential amperometry at one Pt indicator electrode and do so on the basis of the voltammetric curves in Fig. 3.71. One can make a choice from three potentials eu e2 and e3, where the curves are virtually horizontal. Fig. 3.74 shows the current changes concerned during titration at e1 there is no deflection at all as it concerns Fe(III) and Fe(II) only at e2 and e3 there is a deflection at A = 1 but only to an extent determined by the ratio of the it values of the Ce and Fe redox couples. The establishment of the deflection point is easiest at e2 as it simply agrees with the intersection with the zero-current abscissa as being the equivalence point in fact, no deflection is needed in order to determine this intersection point, but if there is a deflection, the amperometric method is not useful compared with the non-faradaic potentiometric titration unless the concentration of analyte is too low. [Pg.214]

Tubular electrodes. Blaedel et al.161 were the first to introduce the TBE, a tubular electrode. It was constructed by melting a Pt cylinder in a glass capillary (see Fig. 5.25), the total length of Pt being 25.5 mm and its diameter 0.75 mm. The authors originally used it for an enzymatic determination of glucose by means of differential amperometry based on the following sequential reactions"12 ... [Pg.367]

Amperometry The techniques and methodology of determining a concentration as a function of current the most popular amperometric measurement technique is voltammetry. [Pg.337]

It is used in IC systems when the amperometric process confers selectivity to the determination of the analytes. The operative modes employed in the amperometric techniques for detection in flow systems include those at (1) constant potential, where the current is measured in continuous mode, (2) at pulsed potential with sampling of the current at dehned periods of time (pulsed amperometry, PAD), or (3) at pulsed potential with integration of the current at defined periods of time (integrated pulsed amperometry, IPAD). Amperometric techniques are successfully employed for the determination of carbohydrates, catecholamines, phenols, cyanide, iodide, amines, etc., even if, for optimal detection, it is often required to change the mobile-phase conditions. This is the case of the detection of biogenic amines separated by cation-exchange in acidic eluent and detected by IPAD at the Au electrode after the post-column addition of a pH modiher (NaOH) [262]. [Pg.409]

Ammonia Gas Sensor. The determination of ammonia is important in process analysis. An ammonia gas electrode is usually used for this purpose. However, volatile compounds such as amines often interfere with the determination of ammonia. Therefore, a sensor based on amperometry is desirable for the determination of ammonia. [Pg.338]


See other pages where Amperometry determination is mentioned: [Pg.438]    [Pg.438]    [Pg.103]    [Pg.458]    [Pg.855]    [Pg.75]    [Pg.295]    [Pg.742]    [Pg.810]    [Pg.221]    [Pg.225]    [Pg.272]    [Pg.22]    [Pg.360]    [Pg.144]    [Pg.153]    [Pg.220]    [Pg.182]    [Pg.279]    [Pg.1442]    [Pg.1463]    [Pg.1487]    [Pg.1491]    [Pg.130]    [Pg.148]    [Pg.103]    [Pg.685]    [Pg.88]    [Pg.63]    [Pg.773]    [Pg.815]    [Pg.387]    [Pg.53]   


SEARCH



Amperometry

Amperometry hydrogen peroxide determination

© 2024 chempedia.info