Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Amperometric detection decoupling

Simple etching of the capillary end served to decouple the electrophoretic current from that of amperometric detection, permitting quantitation of attomole levels of catecholamines from brain microdialyzates.24 A postcolumn reactor using bromine generated electrochemically in situ has been used in the detection of peptide thiols, such as glutathione and cysteine, separated by capillary electrophoresis.25... [Pg.429]

C. -C. Wu, R.-G. Wu, H.-G. Huang, Y.-C. Lin and H.-C. Chang, Three-electrode electrochemical detector and platinum film decoupler integrated with a capillary electrophoresis microchip for amperometric detection., Anal. Chem., 75 (2003) 947-952. [Pg.866]

D. -C. Chen, F.-L. Hsu, D.-Z. Zhan and C.-H. Chen, Palladium film decoupler for amperometric detection in electrophoresis chips, Anal. Chem., 73 (2001) 758-762. [Pg.866]

J. Vickers and C.S. Henry, Simplified current decoupler for microchip capillary electrophoresis with electrochemical and pulsed amperometric detection, Electrophoresis, 26 (2005) 4641-4647. [Pg.867]

C. -Ch.J. Lai, Ch.-h. Chen and F.-H. Ko, In-channel dual-electrode amperometric detection in electrophoretic chips with a palladium film decoupler, J. Chromatogr. A, 1023 (2004) 143-150. [Pg.867]

A Pd film decoupler has also been constructed for amperometric detection of catecholamines. The Pd film has been thermally evaporated onto a plastic chip (without the use of the Cr or Ti adhesion underlayers). Owing to the fast diffusion of H2 on a Pd surface, gas bubbles will not form. Pd is able to absorb H2 produced at the cathode up to a Pd/H ratio of 0.6. This reduces one of the interferences to the EC signal, leading to an improvement of LOD to 0.29 pM dopamine [205,375]. With an optimal decoupler size of 500 pm, up to 6 h of operation was achieved with an electric field of 600 V/cm [375]. [Pg.214]

It was reported that in-channel amperometric detection was possible without using a decoupler. This has been achieved using an electrically isolated (non-grounded, floating) potentiostat [750]. On the other hand, when the CE power supply was battery operated (12-V battery to power 3-kV HV module) and therefore it was electrically isolated from the electrochemical detection system [765], In another report, a portable HV power supply (using 6 V battery for the HV module and 9 V battery for the electrochemical detection circuit) was constructed for CE-EC detection on a glass chip [751],... [Pg.215]

In amperometric detection, there is H2 evolution at the electrode. How can this problem be prevented by using a Pd decoupler near the grounded cathode [205] (2 marks)... [Pg.399]

Three-electrode electrochemical detector and platinum film decoupler integrated with a capillary electrophoresis microchip fin amperometric detection. Anal Chem 75 947-952... [Pg.64]


See other pages where Amperometric detection decoupling is mentioned: [Pg.169]    [Pg.212]    [Pg.215]    [Pg.398]    [Pg.200]    [Pg.599]    [Pg.60]    [Pg.765]    [Pg.527]    [Pg.42]    [Pg.44]    [Pg.470]    [Pg.120]    [Pg.353]    [Pg.461]    [Pg.111]    [Pg.62]    [Pg.335]    [Pg.293]   
See also in sourсe #XX -- [ Pg.398 , Pg.399 ]




SEARCH



Amperometric detection

Decoupler

Decouplers

Decoupling

Decouplings

© 2024 chempedia.info