Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Alumina column chromatography

The reaction of the first-generation dendron 29 with the core, which is a trin-uclear platinum complex (30) bridged by 1,3,5-triethynylmesitylene, in a molar ratio of 3 1 resulted in the formation of the first-generation dendrimer (31). Since the reaction proceeded quantitatively and no side products were observed, the first-generation dendrimer was easily isolated by alumina column chromatography. [Pg.52]

Alumina column chromatography (rice grain, rice straw and soil)... [Pg.554]

Fish Polytron (methanol) or ball mill (hexane) extraction clean-up by GPC and alumina column chromatography GC/NPD 0.01 pg/g 79-97 Muiret al. 1981... [Pg.323]

Saponify (ambient), extract un-saponifiables with petroleum ether. Coprecipitate sterols with digitonin. Extract with petroleum ether. Alumina-column chromatography. [Pg.369]

As in preceding entry, but with alumina-column chromatography before semipreparative HPLC. [Pg.371]

Saponify (hot), extract unsaponifiables with hexane/CH2Cl2, 85 15. Alumina-column chromatography to obtain a vitamin D fraction and a 25(OH)D fraction. [Pg.372]

Digest sample with lipase, extract with pentane. Alumina-column chromatography. [Pg.382]

Treatment of the l-benzyl-2-benzotelluropyrylium salts 55 with base, or even upon alumina column chromatography, leads to deprotonation affording the corresponding exocyclic (Z)-olefin 56 quantitatively (Equation 19)... [Pg.966]

The cleanup steps described failed to remove a trace of impurity that accompanied heptachlor, DDE, and aldrin in the alumina column chromatography. This impurity later appeared in infrared spectra obtained from small samples of these insecticides. [Pg.221]

The same authors reported that TCPM was unstable during a sulfuric acid treatment and that TCPM could not be separated from the lipids by alumina column chromatography [8]. [Pg.33]

Alumina column chromatography has been a common cleanup method in PCDD/PCDF analyses [111, 112], Activated basic aluminum oxide has been used to isolate PCDEs from PCDDs and PCDFs [37, 43, 67], as well as from PCBs [120]. [Pg.186]

Metcalfe-Smith et al. [23] extracted PCAs with DCM and employed the same alumina column chromatography cleanup step as did Murray et al. [24], Using this method, PCA recoveries were reported to be greater than 90% [23], These authors did not encounter problems with degradation of PCAs on alumina as reported by Reiger and Ballschmiter [43]. [Pg.215]

Sample preparation Water was extracted with hexane for chlorpyrifos (a) and benzene for 3,5,6-trichloro-2-pyridinol (TCP) (b) banana samples were prepared using standard Food and Drug Administration procedures based on extraction, solvent partitioning, and silica gel or alumina column chromatography. [Pg.1152]

One glass column for alumina column chromatography, 30-mm inner... [Pg.15]

The extract was subjected to silica gel and alumina column chromatography to give fractions containing anacardic acid, bilobol and cardanol. Further purification with an ODS column furnished anacardic... [Pg.297]

A mixture of 1.0 g p-methoxy-A -nitro-Af-methylaniline, 50 mL methanol, and 50 mL cone. HCl was refluxed for 2 h and then allowed to stand for 20 h at 25°C. The solution was cooled to 0°C, and the solid product was collected by suction filtration. The solid was purified by neutral alumina column chromatography using benzene as the eluent to afford 85% 2-nitro-4-methoxyl-A -methylaniline, m.p. 98-99°C. [Pg.2095]

A mixture of 1.13 g orf/to-isonitrile phenyl trimethylsilyl acetylene (5.68 mmol), 2.10 ethanethiol (28.4 mmol), 0.14 g AIBN (0.85 mmol), and 142.0 mL toluene was refluxed for 15 min and then concentrated in vacuo. The residue was purified by alumina column chromatography using hexanes/EtOAc (10 1) as the eluent to afford 1.57 g 2-ethylthio-3-(l-trimethylsilyl-l -ethylthio)methyl indole as a pale yellow solid, in a yield of 86%, m.p. 94-96°C. [Pg.2460]

Thus alumina column chromatography was used< > for the separation of caroten from chlorophyll in the determination of the former based on the reaction with iodine (cf. p. 131). Carotene is eluted from the alumina column with a petroleum ether-benzene mixture, whereas chlorophyll and other carotenoids remain on the column. [Pg.178]


See other pages where Alumina column chromatography is mentioned: [Pg.49]    [Pg.51]    [Pg.1229]    [Pg.191]    [Pg.280]    [Pg.343]    [Pg.111]    [Pg.556]    [Pg.84]    [Pg.181]    [Pg.300]    [Pg.146]    [Pg.80]    [Pg.23]    [Pg.204]    [Pg.380]    [Pg.290]    [Pg.679]    [Pg.34]    [Pg.312]    [Pg.58]    [Pg.18]    [Pg.464]    [Pg.7]    [Pg.438]    [Pg.148]   
See also in sourсe #XX -- [ Pg.173 ]




SEARCH



Alumina column

Alumina, for column chromatography

Chromatography alumina

Column chromatography

Column chromatography columns

Column chromatography, on alumina

Reverse phase chromatography alumina columns

© 2024 chempedia.info