Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Accuracy of integration

The present analysis clearly indicates that besides a complete peak volume matrix the full matrix analysis requires high accuracy of integrated peak volumes. Therefore, a good signal-to-noise ratio and good methods for peak volume integration are the main prerequisites for a successful full matrix analysis. [Pg.297]

Initial staging. The first study comparing the diagnostic accuracy of integrated [ F]-FDG-PET/CT with CT alone, [ F]-FDG-PET alone and conventional visual correlation of [ F]-FDG-PET and CT in patients with NSCLC was published by Lardinois et al. [43]. Integrated [ F]-FDG-PET/CT provided additional information beyond that provided by visually correlated [ F]-FDG-PET and CT in 41% of the included patients. p F]-FDG-PET/CT also revealed to be significantly... [Pg.154]

One can see that the Born approximation reduces the forward modeling solution to simple quadrature calculation. However, this approximation holds only for a weaJi scatterer (when As (r) is relatively small). We can improve the accuracy of integral approximation significantly if, following the ideas described in Chapter 9 for an electromagnetic field, we introduce a quasi-linear approximation. [Pg.450]

Figure 3.21 The power distribution for a 10 a,s rectangular pulse of 500 MHz RF radiation, (a) Distribution over a 400 kHz range, (b) The power level drops to 97% of the maximum at 5 kHz (10 ppm) on both sides of the center of the spectrum. This can affect the accuracy of integrals for resonances in different regions of the spectrum. (From Petersheim, used with permission.)... Figure 3.21 The power distribution for a 10 a,s rectangular pulse of 500 MHz RF radiation, (a) Distribution over a 400 kHz range, (b) The power level drops to 97% of the maximum at 5 kHz (10 ppm) on both sides of the center of the spectrum. This can affect the accuracy of integrals for resonances in different regions of the spectrum. (From Petersheim, used with permission.)...
Table 1. Accuracy of integration for Lorentzian lines as a function of integration range. Table 1. Accuracy of integration for Lorentzian lines as a function of integration range.
Deuterium lamps emit a continuous UV spectrum (up to about 340 nm, stray light up to 600 nm). The wavelength at which detection actually occurs can be adapted to the absorption maximum of the compound in question but a suitable choice also permits the removal of interfering peaks, thus improving the accuracy of integration or the selectivity. Figure 6.7 compares non-selective (all... [Pg.89]

The faster a time series is sampled, the wider the spectral width in the resultant transform. The longer the time series is sampled, the greater the digital resolution in the spectrum. These parameters must be taken into account when considering the accuracy of integration. For example, a typical peak may be only a few data points wide in FT-NMR, there can be substantial distortions in peak area when a peak is characterized by only two or three data points at half-height. [Pg.615]

As seen from Figure 7.14a and b, the maximum concentration of radicals XXVI monotonously falls as the relative contents of PPIA and PVP is increased, whereas concentrations of radicals XV and XII + XIII vary from 10% to 20% of the average value that is within the accuracy of integration of ESR spectra. This fact is indicative of obvious dependence of the radical XXVI yield on the contents of polymers with... [Pg.230]

Rasaiah J C and Friedman H L 1969 Integral equation computations for 1-1 electrolytes. Accuracy of the method J. Chem. Phys. 50 3965... [Pg.553]

In the connnonly used atomic sphere approximation (ASA) [79], the density and the potential of the crystal are approximated as spherically synnnetric within overlapping imifiBn-tin spheres. Additionally, all integrals, such as for the Coulomb potential, are perfonned only over the spheres. The limits on the accuracy of the method imposed by the ASA can be overcome with the fiill-potential version of the LMTO (FP-LMTO)... [Pg.2213]

The Hemian-Kluk method has been developed further [153-155], and used in a number of applications [156-159]. Despite the formal accuracy of the approach, it has difficulties, especially if chaotic regions of phase space are present. It also needs many trajectories to converge, and the initial integration is time consuming for large systems. Despite these problems, the frozen Gaussian approximation is the basis of the spawning method that has been applied to... [Pg.275]

Computational issues that are pertinent in MD simulations are time complexity of the force calculations and the accuracy of the particle trajectories including other necessary quantitative measures. These two issues overwhelm computational scientists in several ways. MD simulations are done for long time periods and since numerical integration techniques involve discretization errors and stability restrictions which when not put in check, may corrupt the numerical solutions in such a way that they do not have any meaning and therefore, no useful inferences can be drawn from them. Different strategies such as globally stable numerical integrators and multiple time steps implementations have been used in this respect (see [27, 31]). [Pg.484]

Step size is critical in all sim tilation s. fh is is th c iricrcm en t for in tc-grating th c equation s of motion. It uitim atcly deterrn in cs the accuracy of the numerical integration. For rn olecu les with high frequency motion, such as bond vibrations that involve hydrogens, use a small step size. [Pg.89]

Set this threshold Lo a small positive constant (the default value is 10 Hartrcc), Tli is tli resh old is used by HyperCh cm to igu ore all two-cicetron repulsion in tegrals with an absolute value less th an th is value. Tli is option controls the performance of the SCF itera-lious and the accuracy of the wave function and energies since it can decrease the number of ealeulatcd Iwo-elcclrou integrals. [Pg.113]

The second consideration is the geometry of the molecule. The multipole estimation methods are only valid for describing interactions between distant regions of the molecule. The same is true of integral accuracy cutoffs. Because of this, it is common to find that the calculated CPU time can vary between different conformers. Linear systems can be modeled most efficiently and... [Pg.44]

A second issue is the practice of using the same set of exponents for several sets of functions, such as the 2s and 2p. These are also referred to as general contraction or more often split valence basis sets and are still in widespread use. The acronyms denoting these basis sets sometimes include the letters SP to indicate the use of the same exponents for s andp orbitals. The disadvantage of this is that the basis set may suffer in the accuracy of its description of the wave function needed for high-accuracy calculations. The advantage of this scheme is that integral evaluation can be completed more quickly. This is partly responsible for the popularity of the Pople basis sets described below. [Pg.79]

AH electron integrals are computed exactiy, but with no guarantee of accuracy of the prediction or agreement with experiment. [Pg.162]


See other pages where Accuracy of integration is mentioned: [Pg.101]    [Pg.112]    [Pg.23]    [Pg.93]    [Pg.98]    [Pg.355]    [Pg.109]    [Pg.189]    [Pg.194]    [Pg.56]    [Pg.55]    [Pg.101]    [Pg.112]    [Pg.23]    [Pg.93]    [Pg.98]    [Pg.355]    [Pg.109]    [Pg.189]    [Pg.194]    [Pg.56]    [Pg.55]    [Pg.163]    [Pg.476]    [Pg.2220]    [Pg.271]    [Pg.265]    [Pg.97]    [Pg.107]    [Pg.265]    [Pg.508]    [Pg.162]    [Pg.339]    [Pg.121]    [Pg.77]    [Pg.71]    [Pg.673]    [Pg.1972]    [Pg.74]    [Pg.145]   
See also in sourсe #XX -- [ Pg.17 ]




SEARCH



© 2024 chempedia.info