Washing, Sterilizing, and Drying Machine for Stoppers

SUBJECT Washing, Sterilizing, and Drying Machine for Stoppers [Pg.298]

To provide the guideline for validation of the washing, sterilizing and drying machine for stoppers to meet the cGMP requirement [Pg.298]

It is the responsibility of the technical service and quality control managers to follow the procedure. The quality assurance manager is responsible for SOP compliance. [Pg.298]

The number of stoppers should be chosen according to a total stopper-surface of 200 cm. Place the stoppers to be tested into a particle-fiee container with a pair of tweezers. Shake the stoppers for about 30 sec with a filtered and dilute detergent solution. Filter the obtained solution through a 0.45 rm filter, as reference. Repeat the same procedure without stoppers. [Pg.299]

Perform the test and reference test three times. Inspect the filter afterwards visually, using microscope using lateral incident light with an enlargement of 40x. [Pg.299]