Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Viscoelasticity rheological measurements

Figure 11 Schemes of the different geometries that can be used for flow or viscoelastic rheological measurements. From left to right double cylinders or Couette geometry, cone and plate geometry, and parallel plates geometry. Figure 11 Schemes of the different geometries that can be used for flow or viscoelastic rheological measurements. From left to right double cylinders or Couette geometry, cone and plate geometry, and parallel plates geometry.
Polyolefin melts have a high degree of viscoelastic memory or elasticity. First normal stress differences of polyolefins, a rheological measure of melt elasticity, are shown in Figure 9 (30). At a fixed molecular weight and shear rate, the first normal stress difference increases as MJM increases. The high shear rate obtained in fine capillaries, typically on the order of 10 , coupled with the viscoelastic memory, causes the filament to swell (die swell or... [Pg.317]

Viscous Hquids are classified based on their rheological behavior characterized by the relationship of shear stress with shear rate. Eor Newtonian Hquids, the viscosity represented by the ratio of shear stress to shear rate is independent of shear rate, whereas non-Newtonian Hquid viscosity changes with shear rate. Non-Newtonian Hquids are further divided into three categories time-independent, time-dependent, and viscoelastic. A detailed discussion of these rheologically complex Hquids is given elsewhere (see Rheological measurements). [Pg.427]

Rheological measurements also show that PS-PI diblock and PS-P1-PS triblock copolymers with /< 0.2 (for either block) exhibit a liquid-like viscoelastic response, even at temperatures below the ODT (Adams et al. 1994 Han et al. 1995 Sakamoto et al. 1997). Han et al. (1995) and Sakamoto et al. (1997) have observed that the ODT cannot be located for these samples based on a discontinuity in the isochronal shear moduli as a function of temperature but can be obtained from plots of logG versus logG" (Fig. 2.4(c)). [Pg.44]

Integral viscoelastic models. Integral models with a memory function have been widely used to describe the viscoelastic behavior of polymers and to interpret their rheological measurements [37, 41, 43], In general one can write the single integral model as... [Pg.80]

Rheological measurements were carried out at a Dynamic Analyzer Rheometer RDA II from Rheometrics. Parallel plate geometry with a plate diameter of 25 mm was used to perform the tests where thin films of materials of 1 mm thickness were inserted. To ensure the viscoelastic... [Pg.512]

The low shear rheology measurements also show a rapid increase in the viscoelastic properties (modulus and zero shear viscosity) with increase of bentonite concentration above the gel point (> 30 g dm bentonite). Several models have been proposed to account for the elastic properties of concentrated dispersions, of which that originally proposed by van den Tempel (25) and later developed by Papenhuizen (26) seems to be the most appropriate for the present system. According to this model, if the interaction energy minimum between adjacent particles is sufficiently negative, a three-dimensional network structure may ensue, giving an elastic component. Various models can be used to represent the three dimensional structure, the simplest of which would be either an ideal network where all particles are... [Pg.42]

Another well documented, but less widely used method for formulation development is the measurement of electrokinetic properties [14]. These tests require more disdnc-tive/elaborate sample preparation and are mosdy restricted to use during development. Also widely used and relied on are rheological measurements. The scope of rheological measurements ranges from viscosity measurements to the determination of yield points or oscillatory properties, such as the G and G -modules [15]. Since suspoemulsions are not ideal viscous but mostly viscoelastic or dilatant, a wide range of characterization techniques exists. Instrumentation required for this are simple rotary viscosimeters (Brookfield) or more sophisticated stress or shear controlled rotational viscosimeters. [Pg.270]

The cone-plate geometry is widely used in rheological measurements of viscoelastic fluids. The fluid is placed between a plate of radius and a cone of the same radius. The angle, a, between the cone and the plate is usually smaller than 3° (see Fig. 13.19). [Pg.539]

Although providing only a qualitative determination of the level of branching, comparing the linear viscoelastic data of samples from dynamic rheology measurements is a common technique. Plots of the loss angle, as a function of frequency are altered because of branching ... [Pg.262]

Rheology Rheological measurements were performed at 25°C with an ARES 2 KFRT controlled strain rheometer (Rheometric Scientific). For the measurements parallel plates of 50 mm diameter were used. The gels were loaded between the plates (2-mm gap) and allowed to rest for 3 min. A strain sweep (0.1 to 100%) was performed at 1 Hz frequency to determine the range of viscoelasticity for each sample and a 2% strain was selected for all samples. A frequency sweep test (0.1 to 16 Hz) was then performed. Samples of 30 and 50% s/w concentration could not be analyzed because of the difficulty in obtaining samples of proper and constant geometry. [Pg.473]

Rheological measurements were performed in shear using a stress controlled rheometer (Carri-Med CSL 100) operating in cone-plate geometry. Each sample is submitted successively to a first frequency sweep in range 10 3-40 Hz under 3% strain, to a creep and recovery test, and finally to a second frequency sweep identical to the first one. The dynamical strain amplitude (3%) and the value of the creep stress (chosen so as to keep the maximum strain below 10%) were set in order to remain within the linear viscoelasticity domain. Creep and creep recovery were recorded during 20 h and 80 h, respectively, times which allowed the steady state to be reached in all cases. A fresh sample was used for each solvent/temperature combination. [Pg.285]

An exception to the generally observed drag reduction in turbulent channel flow of aqueous polymer solutions occurs in the case of aqueous solutions of polyacrylic acid (Carbopol, from B.F. Goodrich Co.). Rheological measurements taken on an oscillatory viscometer clearly demonstrate that such solutions are viscoelastic. This is also supported by the laminar flow behavior shown in Fig. 10.20. Nevertheless, the pressure drop and heat transfer behavior of neutralized aqueous Carbopol solutions in turbulent pipe flow reveals little reduction in either of these quantities. Rather, these solutions behave like clay slurries and they have been often identified as purely viscous nonnewtonian fluids. The measured dimensionless friction factors for the turbulent channel flow of aqueous Carbopol solutions are in agreement with the values found for clay slurries and may be correlated by Eq. 10.65 or 10.66. The turbulent flow heat transfer behavior of Carbopol solutions is also found to be in good agreement with the results found for clay slurries and may be calculated from Eq. 10.67 or 10.68. [Pg.777]


See other pages where Viscoelasticity rheological measurements is mentioned: [Pg.11]    [Pg.166]    [Pg.612]    [Pg.610]    [Pg.147]    [Pg.229]    [Pg.166]    [Pg.151]    [Pg.11]    [Pg.1197]    [Pg.13]    [Pg.96]    [Pg.175]    [Pg.175]    [Pg.179]    [Pg.597]    [Pg.523]    [Pg.30]    [Pg.264]    [Pg.44]    [Pg.95]    [Pg.2]    [Pg.3]    [Pg.71]    [Pg.381]    [Pg.535]    [Pg.185]    [Pg.65]    [Pg.190]    [Pg.11]    [Pg.412]    [Pg.245]    [Pg.92]    [Pg.69]    [Pg.70]    [Pg.133]    [Pg.260]    [Pg.261]   
See also in sourсe #XX -- [ Pg.2 , Pg.956 , Pg.957 , Pg.958 , Pg.959 , Pg.960 , Pg.961 ]




SEARCH



Rheological measurements

Rheology measuring

Rheology viscoelastic

Rheology viscoelasticity

Viscoelastic measurements

© 2024 chempedia.info