Valves temperature

For any given appHcation of any type of valve, temperature, pressure, and corrosivity must be considered in the same manner as for the piping system itself. Valve vendors specify the temperature, pressure, and general service limitation for their valves and these are indicated in the manufacturers catalogs. [Pg.57]

Are vaporizers provided with automatic gas line shutoff valve, downstream pressure-reducing valve, gas flow control valve, temperature control system and interlocks to shut down gas flow on low vaporizer temperature, and appropriate alarms in a continuously manned control room ... [Pg.84]

Valves are lubricated through pressure-fed oil as well, both at the guides, and at the rocker arm ends. The old fuels which contained lead, lubricated the valve seat (as well as clogging it and the gas passages) and to a tiny degree lubricated the valve guides. With modern steel or stelite and sodium filled valves, temperatures are not so much of a problem as in the earlier days. [Pg.6]

Outlet valve temperature control of cream feeding hopper Heating jacket temperature control of cream feeding hopper Detector for presence of empty tubes Detector for control of product presence in the hopper Feeding of empty tubes... [Pg.404]

Temperature of the intake air will play a role in the combustion process. The temperature affects the air density, which will in turn have an impact on the mass of the air in the cylinder. For every 3°C increase in intake temperature there is an approximate 1% loss in density, which results in about a 1% loss in power. The effects of intake temperature on combustion are not limited to the power loss due to density. It also affects spark knock, spark retardation, elevated under-hood temperatures, and elevated exhaust valve temperatures. [Pg.97]

Easley et al. showed integrated DNA purification, PCR, electrophoretic separation and detection of pathogens in less than 30 min [116]. The assay was performed on a pressure driven four layer glass/PDMS chip with elastomeric valves. Temperature cycling for PCR was achieved by IR radiation. Only the sample lysis step was not integrated in the microfluidic chip. Detection of Bacillus anthracis from infected mice and Bordetella pertussis from a clinical sample was successfully demonstrated. [Pg.324]

To achieve the best precision and accuracy in the determination a very reproducible procedure is necessary. This is best done if the system is computer controlled, including the handling of magnetic valves, temperature readings and reading of the coulometer. The UIC coulometer is equipped with both a parallel and serial (RS232) port and software to acquire the data in the serial mode is available from the manufacturer. [Pg.139]

Radically created polyethene typically contains a total number of 10 to 50 branches per 1000 C atoms. Of these, 10% are ethyl, 50% are butyl, and 40% are longer side chains. With the simplified formulars (6) and (7), not all branches observed could be explained [33,34]. A high-pressure stainless steal autoclave (0.1 to 0.51 MPa) equipped with an inlet and outlet valve, temperature conductor, stirrer, and bursting disk is used for the synthesis. Best performance is obtained with an electrically heated autoclave [35-41]. [Pg.15]

Indication is provided to alert the operator to the actuation of the normal residual heat removal system relief valve. Positive position indication is provided for the normal residual heat removal system relief valve. Temperatures in the safety valve discharge lines are measured, and an... [Pg.222]

Per application flow control valve, pressure control valve, temperature control valve, level control valve, on- ofT control valve, manual control valve, emergency shutdown valve. [Pg.129]

Sample Inlet System, Liquid—A. liquid sampling valve shall be provided, capable of entrapping a fixed volume of sample at a pressure at least 200 psi (1379 kPa) above the vapor pressure of the sample at valve temperature, and introducing this fixed volume into the carrier gas stream ahead of the analyzing column. The fixed sample volume should not exceed 1.0 pL and should be reproducible such that successive runs agree within 2 % on each component peak area. The liquid sampling valve is mounted exterior of any type heated compartment and thus can operate at latoratory ambient conditions. [Pg.393]

Helium at 6 to 8 mL/min Injection System with Splitter Sample valve loop volume = 200-500pl Sample valve temperature = 35° to 45°C Splitter temperature = 150° to 200°C Split ratio = 50 1 to 100 1 Flame Ionization Detector, 300°C Air = 300mL/min ... [Pg.1036]


See other pages where Valves temperature is mentioned: [Pg.169]    [Pg.322]    [Pg.835]    [Pg.281]    [Pg.240]    [Pg.386]    [Pg.24]    [Pg.150]    [Pg.169]    [Pg.300]    [Pg.2670]    [Pg.396]    [Pg.169]    [Pg.602]    [Pg.602]    [Pg.293]    [Pg.48]    [Pg.136]    [Pg.272]    [Pg.368]    [Pg.237]    [Pg.375]    [Pg.562]    [Pg.1036]    [Pg.57]    [Pg.448]   
See also in sourсe #XX -- [ Pg.317 , Pg.318 ]




SEARCH



Valve outlet temperature

Valves ratings, pressure-temperature

Valves temperature markings