Valves regulator isolation

Several In-Room Service Panels are part of this system. Each patient room and other needed locations are equipped with an In-Room Service Panel. The Panel consists of an isolation valve, regulator hand valve (to reduce supply pressure from 250 psi to a usable pressure of 20-30 psi), a pressure indicator gauge, a pressure relief valve, a spring-loaded check valve, and a capped interface port (for maintenance operations only). [Pg.114]

Regulator isolation valve. Usually there is a valve upstream of the regulator, that allows the high pressure side of the panel and the delivery pressure side of the panel to be isolated from each other. [Pg.506]

A control valve consists ot a valve, an actuator, and possiblv one or more valve-control devices. The valves discussed in this section are applicable to throttling control (i.e, vviiere tlovv through the valve is regulated to anv desired amount betvv een maximum and minimum limits). Other valves such as check, isolation, and relict valves are addressed in the next subsection. As defined, control valves are automatic control devices that modify the tliiid tlovv rate as specified bv the controller. [Pg.778]

Valves and regulators are used in pipeline networks to perform a variety of functions. Isolating valves are used to interrupt flows and to shut off... [Pg.138]

Fig. 5.18. Reservior inlet of a JEOL JMS-700 sector instrument with the septum injection port opened. The operation valve switches between evacuation, isolation and admission of the sample a needle valve allows regulation of the sample flow. The GC transfer line crosses in the upper background from the GC (left) to the ion source housing (upper right). Fig. 5.18. Reservior inlet of a JEOL JMS-700 sector instrument with the septum injection port opened. The operation valve switches between evacuation, isolation and admission of the sample a needle valve allows regulation of the sample flow. The GC transfer line crosses in the upper background from the GC (left) to the ion source housing (upper right).
Procedures to run an SDI test call for a 0.45-micron filter pad to be placed with the shiny side up in the filter holder. A small squirt of water from a water bottle is used to wet and completely seat the filter pad. (If the pad shows signs of air bubbles or erratic coverage of foulant of the pad upon removal from the filter holder, the filter was not seated properly and the SDI test is invalid). The isolation valve is opened and the pressure regulator is set to 30 psi. The time it takes to collect 500 ml of water through the 0.45-micron filter pad is then recorded. After this volume of water has been collected, water is allowed to run through the filter continuously for a total time of 15 minutes. If necessary, the pressure should be adjusted to remain at 30 psi. At the end of 15 minutes, the time it takes to collect another... [Pg.35]

VALVE 4 = IMPULSE LINE ISOLATION VALVE TO P/V AND N2 REGULATOR... [Pg.32]

When the cylinder valve is closed, then disconnect or isolate your low pressure equipment from the regulator... [Pg.308]


See other pages where Valves regulator isolation is mentioned: [Pg.171]    [Pg.663]    [Pg.3080]    [Pg.133]    [Pg.31]    [Pg.91]    [Pg.50]    [Pg.965]    [Pg.316]    [Pg.375]    [Pg.392]    [Pg.105]    [Pg.273]    [Pg.287]    [Pg.283]    [Pg.290]    [Pg.281]    [Pg.165]    [Pg.93]    [Pg.129]    [Pg.50]    [Pg.91]    [Pg.46]    [Pg.157]    [Pg.160]    [Pg.34]    [Pg.316]    [Pg.243]    [Pg.283]    [Pg.788]    [Pg.129]    [Pg.131]    [Pg.91]    [Pg.125]    [Pg.129]    [Pg.129]    [Pg.1126]    [Pg.144]   
See also in sourсe #XX -- [ Pg.506 ]