Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Vacuum periodic potential

Cryogenic cold traps in Zone 2A. (Capture process radioactive noble gas in the vacuum system flow to control release.) Plugged trap or broken vacuum line Mechanical malfunction or worker error Control and monitoring system indications and periodic maintenance inspections Redundant cold traps provide multiple flow paths for vacuum. Loss of vacuum and potential release of noble gas. [Pg.453]

In the development of thiophene chemistry three periods can be clearly distinguished the Victor Meyer era, the Steinkopf period, and the modem development starting with the discovery of the synthesis of thiophene from butane and sulfur, making thiophene potentially available in unlimited amounts. Hartough in his well-known monograph, has reviewed the intense and hectic thiophene research toward the end of the 1940 s carried out mainly at the Socony-Vacuum laboratories, but also at many academic institutions. An article by Nord et al. appeared in 1955 in which the research work in thiophene chemistry at Fordham University, as well as progress in general up to 1954, was reviewed. [Pg.2]

While in previous ab initio smdies the reconstructed surface was mostly simulated as Au(lll), Feng et al. [2005] have recently performed periodic density functional theory (DFT) calculations on a realistic system in which they used a (5 x 1) unit cell and added an additional atom to the first surface layer. In their calculations, the electrode potential was included by charging the slab and placing a reference electrode (with the counter charge) in the middle of the vacuum region. From the surface free energy curves, which were evaluated on the basis of experimentally measured capacities, they concluded that there is no necessity for specific ion adsorption [Bohnen and Kolb, 1998] and that the positive surface charge alone would be sufficient to lift the reconstmction. [Pg.144]

The free theory for the quench models is provided by the potential (4), where A = 0 and m2(t) changes signs either instantaneously or for a finite period. In the Minkowski spacetime, we can apply the LvN method simply by letting R = 1. Before the phase transition (rrii = (mg + m2)1/2), all the modes are stable and oscillate around the true vacuum ... [Pg.285]

The effect of the surface of the box on the solute is of major importance in the simulation of systems such as the one described here. The sudden cut-off of long-range nonbonded potentials at the box surface (beyond which is vacuum) would have an unnatural effect on the dynamics of the simulation. Only an extremely large system size could ensure a small influence of this surface effect on the solute. The computational cost of such a large system would be prohibitive. For this reason, periodic boundary conditions are used. The image of the simulation box is translated repeatedly to form an infinite lattice. When a particle in the simulation box moves, the image in all other translated boxes moves correspond-... [Pg.123]

The work functions for low-index surfaces of the 4d transition metals have been calculated by a full-potential linear-muffin-tin-orbital method using a slab geometry (a periodic arrangement of 7-layer metal slabs and 10-layer vacuum slabs) (29), and the results (Fig. 8) agree well with experimental results. This is a considerable improvement with respect to extended Hiickel calculations for slab [30 (see footnote 21) ] or cluster [i0 (see Chapter 3)] geometries, which usually yield values closer to the atomic ionization energies. However, the shape of the DOS curves and the relative position of the Fermi level as found by the extended Hiickel calculations are reasonably similar to those obtained by the more sophisticated methods. Therefore, it seems that the major error is in the determination of the dipole layer potential. (Further analysis of this topic would lead us beyond the scope of this chapter.)... [Pg.13]

To avoid potential water-vacuum interface problems that might arise in a MD simulation, periodic boundary conditions arc commonly used." Basically, a protein is surrounded by a rectangular hox of water with a defined number of water structures. This water box is then surrounded un each face by another water box. When the MD simulation is being carried out. water near the edges of the central box containing the protein may leave and be replaced with a water coming from the water box on the opposite side. This procedure ensures that the waters inside the central water box remain constant. [Pg.934]


See other pages where Vacuum periodic potential is mentioned: [Pg.80]    [Pg.127]    [Pg.35]    [Pg.112]    [Pg.113]    [Pg.113]    [Pg.454]    [Pg.486]    [Pg.53]    [Pg.100]    [Pg.135]    [Pg.70]    [Pg.103]    [Pg.473]    [Pg.231]    [Pg.172]    [Pg.94]    [Pg.136]    [Pg.143]    [Pg.232]    [Pg.197]    [Pg.747]    [Pg.265]    [Pg.780]    [Pg.1063]    [Pg.1611]    [Pg.117]    [Pg.40]    [Pg.172]    [Pg.241]    [Pg.330]    [Pg.211]    [Pg.211]    [Pg.211]    [Pg.124]    [Pg.1980]    [Pg.139]    [Pg.562]    [Pg.40]    [Pg.437]    [Pg.574]    [Pg.27]   
See also in sourсe #XX -- [ Pg.2 , Pg.314 ]




SEARCH



Periodic potential

Vacuum potentials

© 2024 chempedia.info