Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Tyrosine analysis

However, the use of a HPLC separation step enabled a remarkable acceleration of the deconvolution process. Instead of preparing all of the sublibraries, the c(Arg-Lys-O-Pro-O-P-Ala) library was fractionated on a semipreparative HPLC column and three fractions as shown in Fig. 3-2 were collected and subjected to amino acid analysis. According to the analysis, the least hydrophobic fraction, which eluted first, did not contain peptides that included valine, methionine, isoleucine, leucine, tyrosine, and phenylalanine residues and also did not exhibit any separation ability for the tested racemic amino acid derivatives (Table 3-1). [Pg.64]

The thermal properties of tyrosine-derived poly(iminocarbonates) were also investigated. Based on analysis by DSC and thermogravi-metric analysis, all poly(iminocarbonates) decompose between 140 and 220 C. The thermal decomposition is due to the inherent instability of the iminocarbonate bond above 150°C and is not related to the presence of tyrosine derivatives in the polymer backbone. The molecular structure of the monomer has no significant influence on the degradation temperature as indicated by the fact that poly(BPA.-iminocarbonate) also decomposed at about 170 C, while the structurally analogous poly(BPA-carbonate) is thermally stable up to 350 C. [Pg.221]

Because LCEC had its initial impact in neurochemical analysis, it is not, surprising that many of the early enzyme-linked electrochemical methods are of neurologically important enzymes. Many of the enzymes involved in catecholamine metabolism have been determined by electrochemical means. Phenylalanine hydroxylase activity has been determined by el trochemicaUy monitoring the conversion of tetrahydro-biopterin to dihydrobiopterin Another monooxygenase, tyrosine hydroxylase, has been determined by detecting the DOPA produced by the enzymatic reaction Formation of DOPA has also been monitored electrochemically to determine the activity of L-aromatic amino acid decarboxylase Other enzymes involved in catecholamine metabolism which have been determined electrochemically include dopamine-p-hydroxylase phenylethanolamine-N-methyltransferase and catechol-O-methyltransferase . Electrochemical detection of DOPA has also been used to determine the activity of y-glutamyltranspeptidase The cytochrome P-450 enzyme system has been studied by observing the conversion of benzene to phenol and subsequently to hydroquinone and catechol... [Pg.29]

Figure 2 Depiction of the active ( open ) and inactive ( closed ) conformations of Src kinase based on the analysis of x-ray structures of c-Src tyrosine kinase crystallized in its inactive state [7]. The stabilization of the inactive conformation is influenced by multiple events including intramolecular binding of the tyrosine-phosphorylated C-terminus tail to the SH2 domain as well as interactions between the SH3 domain and the SH2-kinase linker. CT, C-terminal NT, N-terminal. [Pg.37]

A murine male germ cell-assocated kinase (mak) was isolated by virtue of its weak homology to the v-ros tyrosine kinase (Matsushime et al., 1990). Although it was isolated because of its homology to a tyrosine kinase, sequence analysis revealed that it belongs to the serine/threonine... [Pg.30]

Rachel, K., Asuncionpunzalan, E. and London, E. (1995) Anchoring of tryptophan and tyrosine analogs at the hydrocarbon polar boundary in model membrane-vesicles - paralax analysis of fluorescence quenching induced by nitroxide-labelled phospholipids. Biochemistry 34,15475-15479. [Pg.334]

S. W. Fox (from 1984, director of the Institute for Molecular and Cellular Evolution of the University of Miami) made the highly controversial suggestion that the amino acid sequences in the proteinoids are not random. Nakashima prepared a thermal polymer from glutamic acid, glycine and tyrosine the analysis showed that two tyrosine-containing tripeptides had been formed pyr-Glu-Gly-Tyr and pyr-Glu-Tyr-Gly (Nakashima et al 1977). The result was confirmed (Hartmann, 1981). A closer examination of the reaction mechanism showed that the formation of these two tripeptides under the reaction conditions used depends on three parameters ... [Pg.139]

In the solid, dynamics occurring within the kHz frequency scale can be examined by line-shape analysis of 2H or 13C (or 15N) NMR spectra by respective quadrupolar and CSA interactions, isotropic peaks16,59-62 or dipolar couplings based on dipolar chemical shift correlation experiments.63-65 In the former, tyrosine or phenylalanine dynamics of Leu-enkephalin are examined at frequencies of 103-104 Hz by 2H NMR of deuterated samples and at 1.3 x 102 Hz by 13C CPMAS, respectively.60-62 In the latter, dipolar interactions between the 1H-1H and 1H-13C (or 3H-15N) pairs are determined by a 2D-MAS SLF technique such as wide-line separation (WISE)63 and dipolar chemical shift separation (DIP-SHIFT)64,65 or Lee-Goldburg CP (LGCP) NMR,66 respectively. In the WISE experiment, the XH wide-line spectrum of the blend polymers consists of a rather featureless superposition of components with different dipolar widths which can be separated in the second frequency dimension and related to structural units according to their 13C chemical shifts.63... [Pg.15]

Consider one small molecule, phenylalanine. It is an essential amino acid in our diet and is important in protein synthesis (a component of protein), as well as a precursor to tyrosine and neurotransmitters. Phenylalanine is one of several amino acids that are measured in a variety of clinical methods, which include immunoassay, fluorometry, high performance liquid chromatography (HPLC see Section 4.1.2) and most recently MS/MS (see Chapter 3). Historically, screening labs utilized immunoassays or fluorimetric analysis. Diagnostic metabolic labs used the amino acid analyzer, which was a form of HPLC. Most recently, the tandem mass spectrometer has been used extensively in screening labs to analyze amino acids or in diagnostic labs as a universal detector for GC and LC techniques. Why did MS/MS replace older technological systems The answer to this question lies in the power of mass spectrometer. [Pg.289]


See other pages where Tyrosine analysis is mentioned: [Pg.691]    [Pg.691]    [Pg.6836]    [Pg.691]    [Pg.691]    [Pg.6836]    [Pg.206]    [Pg.77]    [Pg.152]    [Pg.511]    [Pg.178]    [Pg.1031]    [Pg.1498]    [Pg.42]    [Pg.210]    [Pg.33]    [Pg.99]    [Pg.107]    [Pg.338]    [Pg.132]    [Pg.252]    [Pg.100]    [Pg.101]    [Pg.51]    [Pg.56]    [Pg.173]    [Pg.66]    [Pg.179]    [Pg.241]    [Pg.263]    [Pg.186]    [Pg.329]    [Pg.16]    [Pg.290]    [Pg.228]    [Pg.25]    [Pg.1037]    [Pg.35]    [Pg.212]    [Pg.418]    [Pg.704]    [Pg.5]    [Pg.5]    [Pg.182]   
See also in sourсe #XX -- [ Pg.1070 , Pg.1076 , Pg.1089 , Pg.1103 ]




SEARCH



Tyrosine adsorption analysis

© 2024 chempedia.info