Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Treatment signal

After consideration of the different measurement methods we now focus on typical measurement types which are all based on one of the voltage excitation methods but differ in the excitation and the electrical treatment signal in between repeated measurements. [Pg.58]

The fatigue treatment signal is interrupted regularly for hysteresis measurements to monitor the development of the hysteresis shape, or at least the polarization values. These intermediate hysteresis measurements are performed after increasing time intervals, e.g. in such a... [Pg.67]

Fig. 3. Chronocoulometric measurement. Representative chronocoulometric curves of signal-on aptasensor for the control sample without ATP (C( J and the sample with ATP (< sainpie)- Intercepts at f=0 In chronocoulometric curves represent redox charges of RuHex bound to DMA. Signal Is defined as the difference In the redox charge of RuHex with and without ATP treatment, which Is equal to the difference In the chronocoulometric Intercept at t= 0 with and without ATP treatment (signal = Q3, ,p 3-... Fig. 3. Chronocoulometric measurement. Representative chronocoulometric curves of signal-on aptasensor for the control sample without ATP (C( J and the sample with ATP (< sainpie)- Intercepts at f=0 In chronocoulometric curves represent redox charges of RuHex bound to DMA. Signal Is defined as the difference In the redox charge of RuHex with and without ATP treatment, which Is equal to the difference In the chronocoulometric Intercept at t= 0 with and without ATP treatment (signal = Q3, ,p 3-...
The image without treatment (Fig lb) should be compared with the deconvolved image of the rod (Fig. 2b). The dimension of the rod is well restored and the contour is reinforced by the signal processing. [Pg.749]

A valuable handbook describing the many uses of nonlinear optics for spectroscopy. The focus of the book is a unified treatment of and methods for modelling the signal. [Pg.282]

Treatment of 2 butanone (1 mole) with Br2 (2 moles) in aqueous HBr gave C4HgBr20 The H NMR spectrum of the product was charactenzed by signals at 8 1 9 (doublet three protons) 4 6 (singlet two protons) and 5 2 (quartet one proton) Identify this compound... [Pg.790]

Since the analyte and internal standard in any sample or standard receive the same treatment, the ratio of their signals will be unaffected by any lack of reproducibility in the procedure. If a solution contains an analyte of concentration Ca, and an internal standard of concentration, Cis, then the signals due to the analyte, Sa, and the internal standard. Sis, are... [Pg.116]

Preprocessor. A device in a data-acquisition system that performs a significant amount of data reduction by extracting specific information from raw signal representations in advance of the main processing operation. A preprocessor can constitute the whole of a data-acquisition interface, in which case it must also perform the data-acquisition task (conversion of spectrometer signal to computer representation), or it can specialize solely in data treatment. [Pg.431]

Optimization lefeis to the step in the analytical process (Fig. 2) where some sort of treatment is performed on samples to generate taw data which can be in the form of voltages, currents, or other analytical signals. These data have yet to be caUbrated in terms of chemical concentrations. [Pg.430]

Sample pre-treatment. Novel procedures of electrochemical sample treatment have been proposed to decrease the signal interference with native cholinesterase inhibitors present in fruits and vegetables. Polyphenolic compounds were removed by electrolysis with soluble A1 anode followed by the oxidation of thionic pesticides with electrogenerated chlorine. The procedure proposed makes it possible to decrease the background current and the matrix effect by 80-90%. Thus, the detection limits of about 5 ppb of Pai athion-Methyl and Chloropyrifos-Methyl were obtained in spiked grape juice without any additional sepai ation or pre-concentration stages. [Pg.295]

The effect of electrochemical sample treatment on the signal selectivity in multi-component mixtures is discussed. [Pg.295]

Eigure 3.56 depicts LEIS spectra for two completely different types of AI2O3 sample, i. e. a-alumina (sapphire) and y-alumina (a powder with high specific surface area) which show very similar results in both cases after thermal treatment at 400 °C [3.142]. Reduction of the A1 signal in y-alumina was ascribed to shielding by hydroxyl groups formed by water molecules, which are typical adsorbates on y-alu-mina. [Pg.155]

We have next to consider the measurement of the relaxation times. Each t is the reciprocal of an apparent first-order rate constant, so the problem is identical with problems considered in Chapters 2 and 3. If the system possesses a single relaxation time, a semilogarithmic first-order plot suffices to estimate t. The analytical response is often solution absorbance, or an electrical signal proportional to absorbance or to another physical property. As shown in Section 2.3 (Treatment of Instrument Response Data), the appropriate plotting function is In (A, - Aa=), where A, is the... [Pg.142]

Treatment of a series of 1,2-dithiols (136) including ds-cyclohexane-1,2-dithiol with AI2CI6 in CH2CI2 at 25°C led to persistent ESR signals due to the corresponding 1,2-dithietane radical cations (g = 2.0187 0.0003)... [Pg.247]


See other pages where Treatment signal is mentioned: [Pg.473]    [Pg.199]    [Pg.480]    [Pg.47]    [Pg.261]    [Pg.473]    [Pg.199]    [Pg.480]    [Pg.47]    [Pg.261]    [Pg.275]    [Pg.346]    [Pg.1191]    [Pg.1435]    [Pg.2066]    [Pg.2098]    [Pg.2817]    [Pg.46]    [Pg.118]    [Pg.233]    [Pg.618]    [Pg.199]    [Pg.380]    [Pg.171]    [Pg.198]    [Pg.233]    [Pg.337]    [Pg.333]    [Pg.202]    [Pg.30]    [Pg.323]    [Pg.342]    [Pg.295]    [Pg.522]    [Pg.247]    [Pg.86]    [Pg.213]    [Pg.163]    [Pg.20]    [Pg.123]   
See also in sourсe #XX -- [ Pg.58 ]




SEARCH



A2 Treatment of TGA signals

Acoustic signal treatment

© 2024 chempedia.info