Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Trace analysis geological samples

The technique is used predominantly for the isolation of a single chemical species prior to a determination and to a lesser extent as a method of concentrating trace quantities. The most widespread application is in the determination of metals as minor and trace constituents in a variety of inorganic and organic materials, e g. the selective extraction and spectrometric determination of metals as coloured complexes in the analysis of metallurgical and geological samples as well as for petroleum products, foodstuffs, plant and animal tissue and body fluids. [Pg.69]

Flame atomic absorption spectrometry can be used to determine trace levels of analyte in a wide range of sample types, with the proviso that the sample is first brought into solution. The methods described in Section 1.6 are all applicable to FAAS. Chemical interferences and ionization suppression cause the greatest problems, and steps must be taken to reduce these (e.g. the analysis of sea-water, refractory geological samples or metals). The analysis of oils and organic solvents is relatively easy since these samples actually provide fuel for the flame however, build-up of carbon in the burner slot must be avoided. Most biological samples can be analysed with ease provided that an appropriate digestion method is used which avoids analyte losses. [Pg.51]

For the largest field of application for LA-ICP-MS - geological research - many different geological and glass standard reference materials are available. Using standard reference materials in LA-ICP-MS, analytical results for trace analysis in homogeneous samples can be obtained with an accuracy better than 10%, and a precision of 2-5% is also possible.25 If no suitable CRM... [Pg.192]

For measurements of isotope ratios or isotope abundances, any of the mass spectrometers discussed in the previous chapters, such as SSMS, LIMS, GDMS56 and LA-ICP-MS,6 are of benefit for the direct isotope analysis of solid samples. SSMS and LIMS are rarely applied in isotope analysis due to their relatively low precision. Several applications of the isotope dilution technique as a calibration strategy in SSMS, mostly on geological samples, are known.57-59 GDMS has been mostly applied in multi-element trace analysis and depth profiling and plays only a minor role... [Pg.226]

Selected applications of inorganic mass spectrometry in trace analysis of geological samples are summarized in Table 9.34.3 8 9 52... [Pg.398]


See other pages where Trace analysis geological samples is mentioned: [Pg.634]    [Pg.671]    [Pg.234]    [Pg.3]    [Pg.210]    [Pg.19]    [Pg.335]    [Pg.56]    [Pg.396]    [Pg.153]    [Pg.154]    [Pg.190]    [Pg.195]    [Pg.195]    [Pg.202]    [Pg.210]    [Pg.272]    [Pg.274]    [Pg.388]    [Pg.389]    [Pg.392]    [Pg.392]    [Pg.393]    [Pg.393]    [Pg.395]    [Pg.396]    [Pg.396]    [Pg.396]    [Pg.407]    [Pg.517]    [Pg.153]    [Pg.154]    [Pg.190]    [Pg.195]    [Pg.195]    [Pg.202]    [Pg.210]    [Pg.272]    [Pg.274]    [Pg.388]    [Pg.389]   