Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Towers intervals

Dimensions The dimensions of fireclay brick may differ from red shale s. Fireclay sizes can be modular (9" x 4.5" x 2.5" or 3") or the same as red shale (8" X 3.75" X 2.25" or 4.5"). Fireclay acid brick tends to be more dimensionally true than red shale and is available in a wider variety of masonry shapes (domestically). Fireclay is also used to fabricate many tower intervals such as packing supports, saddles, spargers, and feed boxes to name a few. [Pg.181]

The last batch of MIC, before the accident, was produced in the interval October 7-22, 1984. At the end of the campaign the E610 storage tank contained about 42 tons of MIC, and the E61 i storage tank contained about 20 tons. After which, MIC production was shut down, and parts of the plant were dismantled for maintenance. The flare tower was shut down to replace a piece of corroded pipe. [Pg.253]

Uniform liquid flow is essential if the best use is to be made of the packing and, if the tower is high, re-distributing plates are necessary. These plates are needed at intervals... [Pg.215]

With packed towers it is considerably more difficult to arrange for cooling, and it is usually necessary to remove the liquid stream at intervals down the column and to cool externally. Coggan and Bourne149 have presented a computer programme to enable the economic decision to be made between an adiabatic absorption tower, or a smaller isothermal column with interstage cooling. [Pg.681]

The pH and solids content of liquid in the recycle loop of each spray tower and of the lime slurry were monitored and recorded by plant personnel at 4-h intervals during the entire test period. The pH and solids content of the recycled liquid ranged from 5.2 to 6.8 and 5.2 to 8.7%, respectively for the lime slurry, the ranges were 4.8 to 5.9, and 12.2 to 12.8%, respectively. [Pg.176]

The Cooling Tower Institute (1967) standardized their work in terms of a Chebyshev numerical integration of Eq. (9.25). In this method, integrands are evaluated at four temperatures in the interval, namely,... [Pg.278]

Fig. 4.3-9 the A -.splitting in the other band is not resolved). The second parallel band (i/[ at 3336.2 cm ) is split much less, due to inversion doubling with AF = 1.8 cm. The P 4 fundamental at 1627 cm is a perpendicular band with the Q branch lines compressed in a smaller spectral interval compared to that of the CHyTspectrum. Another example of a spectrum which resembles those recorded with tower resolution, is the gas phase spectrum of benzene shown in Fig. 4.3-10. The fingerprint region below 2000 cm exhibits the mo.st intense fundamental (v ), which is a parallel band, at 671 cm , The two perpendicular bands at 1485 cm (vis) and 1037 cm (ph) demonstrate similar features. Fig. 4.3-9 the A -.splitting in the other band is not resolved). The second parallel band (i/[ at 3336.2 cm ) is split much less, due to inversion doubling with AF = 1.8 cm. The P 4 fundamental at 1627 cm is a perpendicular band with the Q branch lines compressed in a smaller spectral interval compared to that of the CHyTspectrum. Another example of a spectrum which resembles those recorded with tower resolution, is the gas phase spectrum of benzene shown in Fig. 4.3-10. The fingerprint region below 2000 cm exhibits the mo.st intense fundamental (v ), which is a parallel band, at 671 cm , The two perpendicular bands at 1485 cm (vis) and 1037 cm (ph) demonstrate similar features.
Thermal pollution, control of 89-90 Title page for reports, 455-457 Tolerance intervals, 759 Total capital investment, 157 Towers, cost of 707-713,810 TOXLINE, 48... [Pg.909]

The plot of max(-H) in Fig. 4.46 shows, how the efficiency and the oxygen utilization behave with liquid height (basis of Bayer s Tower biology). The fact, that 40° C is more favorable than 20° C, can be explained by the increase of Sc and hence kt in this temperature interval not yet being nullified by the simultaneous decrease of Ac, due to Cs(T). [Pg.204]

Steady-state procedures that require routine operator intervention can be either event- or time-based. Event-based procedures are usually performed in response to a system change or condition. For example, with regard to the cooling tower example, the facility may have event-based procedures to handle issues such as adding chemicals to the water, or controlling the temperature of the water. Time-based procedures are those that are to take place at a specified time interval. For example, the operator may have to catch a sample of the cooling water every 4 hours in order to check the chemical concentrations in the water. Many maintenance-related activities, such as checking the lube oil level in pumps, are time based. [Pg.289]


See other pages where Towers intervals is mentioned: [Pg.391]    [Pg.160]    [Pg.41]    [Pg.306]    [Pg.287]    [Pg.139]    [Pg.601]    [Pg.582]    [Pg.587]    [Pg.191]    [Pg.133]    [Pg.41]    [Pg.88]    [Pg.53]    [Pg.161]    [Pg.391]    [Pg.242]    [Pg.160]    [Pg.1606]    [Pg.101]    [Pg.42]    [Pg.43]    [Pg.1255]    [Pg.2976]    [Pg.98]    [Pg.120]    [Pg.391]    [Pg.627]    [Pg.631]    [Pg.176]    [Pg.192]    [Pg.321]    [Pg.224]    [Pg.495]    [Pg.1602]    [Pg.72]   
See also in sourсe #XX -- [ Pg.228 , Pg.229 , Pg.230 , Pg.231 ]




SEARCH



© 2024 chempedia.info