Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Total gradient method

In addition to SSM, other methods like the total gradient method (TGM) present... [Pg.151]

Many gradient methods approximate the energy surface at step by a quadratic expression in terms of the coordinate vector the total energy the gradient and the Hessian... [Pg.238]

Signals for methyl paraben were monitored with UV detection at 254 nm. The signal for rhodamine 110 chloride was monitored via fluorescence detection with an excitation filter of 482 nm (35 nm bandwidth) and emission filter of 535 nm (40 nm bandwidth). A gradient method (same as the one in Figure 6.16) was used. The compositions of mobile phases A and B were 5 95 H20 CH3CN with 0.1 HCOOH and CH3CN with 0.085% HCOOH, respectively, with a total flow rate of 300 fiL/ min (corresponding to 12.5 /rL/min for each column). [Pg.173]

Alternative numerical methods exist, where one minimises the total elastic energy E of the network with the lattice displacement vector u dE/dui = 0 for all the internal modes of the network. This gives dN simultaneous equations for the displacement vector for the N internal modes of the network. The resulting set of linear equations is solved numerically using, for example, the Jacobi conjugate gradient method (see... [Pg.103]

Figure 1 Separation of a chromatographic test mixture by a traditional gradient method. Separation was performed on Waters Alliance HPLC System (Waters Corporation, Milford, MA) and a 3.9 by 150mm 5 micron particle size Symmetry Cl8 column at 30°C. The mobile phase consisted of 0.1% phosphoric acid as the A solvent, and acetonitrile as the B solvent, run as a linear gradient from 0-80% B over 40 minutes at 1.0 mL/min. Total analysis time does not include twenty minutes of post run reequilibration of the column and system. UV detection at 254nm, and a 20 pL injection was used. Peaks 1-12 (O.lmg/mL each in 50/50 methanol/water) are uracil, theophy-line, acetylfuran, acetanilide, acetyl-, propio-, butyro-, benzo-, valero-, hexano-, hep-tano-, and octano-phenone, respectively. Figure 1 Separation of a chromatographic test mixture by a traditional gradient method. Separation was performed on Waters Alliance HPLC System (Waters Corporation, Milford, MA) and a 3.9 by 150mm 5 micron particle size Symmetry Cl8 column at 30°C. The mobile phase consisted of 0.1% phosphoric acid as the A solvent, and acetonitrile as the B solvent, run as a linear gradient from 0-80% B over 40 minutes at 1.0 mL/min. Total analysis time does not include twenty minutes of post run reequilibration of the column and system. UV detection at 254nm, and a 20 pL injection was used. Peaks 1-12 (O.lmg/mL each in 50/50 methanol/water) are uracil, theophy-line, acetylfuran, acetanilide, acetyl-, propio-, butyro-, benzo-, valero-, hexano-, hep-tano-, and octano-phenone, respectively.
Second, both the steepest-descent and the conjugate-gradient methods lead to the closest minimum independent of whether one of a lower total energy exists. [Pg.321]

For the example presented in Figure 2.20, it is necessary to shorten the Iq by a factor of 2.8 for the first optimization step and by a factor of 6.2 for both steps in total. It can be seen that the duration of the gradient time also corresponds to the reduction in analysis time. If (q is not altered in a gradient method and only the two rules for isocratic optimization are considered, the analysis time will not be markedly reduced and the chromatogram will look different. [Pg.109]

The intramolecular force-field for the state was determined by using the SCF gradient method. The intermolecular potential was taken as a sum of atom-atom pair functions with parameters obtained as a fit to ab initio data for the rare gas-formaldehyde system[66]. A total of 18 and Ilk basis functions were needed in the V7=0 and V7=l states respectively to obtain cross sections converged to within 10% or better. [Pg.317]

The general assumption in the gradient method is that the total intensity of the image sequence is constant ... [Pg.280]


See other pages where Total gradient method is mentioned: [Pg.341]    [Pg.754]    [Pg.287]    [Pg.168]    [Pg.173]    [Pg.75]    [Pg.138]    [Pg.17]    [Pg.28]    [Pg.115]    [Pg.457]    [Pg.179]    [Pg.91]    [Pg.208]    [Pg.765]    [Pg.788]    [Pg.561]    [Pg.287]    [Pg.321]    [Pg.202]    [Pg.222]    [Pg.322]    [Pg.116]    [Pg.223]    [Pg.173]    [Pg.87]    [Pg.99]    [Pg.183]    [Pg.291]    [Pg.678]    [Pg.235]    [Pg.347]    [Pg.308]    [Pg.553]    [Pg.300]    [Pg.642]    [Pg.69]    [Pg.233]   
See also in sourсe #XX -- [ Pg.151 ]




SEARCH



Gradient method

© 2024 chempedia.info