Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Threshold selection

Because of their better side effect profile compared with clomipramine, including their lower propensity to decrease the seizure threshold, selective SRIs (SSRIs) have been receiving increasing attention as a treatment for the interfering symptoms associated with autistic disorder and other PDDs. [Pg.570]

A different approach to threshold selection is based on fuzzy logic [14], By adopting this approach, the value that represents the crisp discriminant between faults and disturbances is replaced by a fuzzy set, characterized by a membership function. Hence, a yes-no decision is replaced by a continuous indication of the faulty level. [Pg.128]

N. Otsu, A threshold selection method from gray-level histograms, IEEE Trans. Syst. Man. Cybern. 9(1), 62-66 (1979). [Pg.228]

For compression, other threshold selection criteria include the compression ratio (CR), the mean-square error (MSE), and the local point-wise error of approximation, which are discussed in more detail in [13]. In this chapter, the universal threshold given in Eq. (13) will be used for both filtering and compression. Two thresholding techniques have been studied Hard thresholding and Soft thresholding [4,6,22] ... [Pg.132]

Population size Number of generations Mutation rate Crossover rate Convergence threshold Selection method Bits per parameter Populations... [Pg.13]

The output is the label object or background which, due to its dichotomous nature, can be represented as a Boolean variable 1 or 0 . In principle, the test condition could be based upon any visual property of data set. The central question in thresholding then becomes How do we choose the threshold While there is no universal procedure for threshold selection that will work on all images, there are a variety of alternatives. A variety of techniques have been devised to automatically choose a threshold. [Pg.352]

In this case, experiments were carried out and ideal and non-ideal conditions were outlined in order to initiate quantitative experiments, as shown in Fig. 6. Depending on the threshold selected (about 1 mAU), one blank run was carried out under ideal conditions for quantification of LOD and LOQ by way of a linear response range. The principal effects on the separation of vitamins A and E led to doubts regarding some chromatograms because of the non-ideal drift. The accommodation effect on the column may be an explanation for this. [Pg.2398]

J.S.Weszka, A Survey of Threshold Selection Techniques, Comput. graph, image process., 7,259- (1978)... [Pg.789]

The threshold selection method consists of two steps. The proposed selection method will utilize saturation formula base on HSI color space. Then, the resultant image will be used as the input for clustering algorithm. The steps are ... [Pg.618]


See other pages where Threshold selection is mentioned: [Pg.411]    [Pg.212]    [Pg.164]    [Pg.261]    [Pg.142]    [Pg.371]    [Pg.372]    [Pg.380]    [Pg.128]    [Pg.185]    [Pg.411]    [Pg.89]    [Pg.678]    [Pg.47]    [Pg.411]    [Pg.131]    [Pg.245]    [Pg.58]    [Pg.48]    [Pg.313]    [Pg.446]    [Pg.439]    [Pg.757]    [Pg.60]    [Pg.618]    [Pg.84]    [Pg.484]   
See also in sourсe #XX -- [ Pg.131 ]




SEARCH



© 2024 chempedia.info