Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Thermal measurement techniques direct

In this article we have summarized the use of both photochemical and more classical thermal kinetics techniques to deduce the nature of intermediates in the ambient temperature, fluid solution chemistry of several triruthenium clusters. In some cases the photochemically generated intermediates appear to be the same as those proposed to be formed along thermal reaction coordinates, while in other cases unique pathways are the results of electronic excitation. The use of pulse photolysis methodology allows direct observation, and the measurement of the reaction dynamics of such transients and provides quantitative evaluation of the absolute reactivities of these species. In some cases, detailed complementary information regarding... [Pg.141]

The first test case, useful for future comparison, involved the measurements without any obstructions. That is, a typical boundary layer over a relatively smooth surface (the wind tunnel ground plane covered with plywood) was studied. No unexpected phenomena were found, thereby validating the thermal anemometry technique and acquisition algorithms employed, for flows with a predominant wind direction. For a freestream speed of / , the time-averaged velocity and turbulence intensity distributions are shown in Fig. 3.39,(A). These data allow the determination of the boundary... [Pg.173]

In this article, we do not discuss various experimental techniques developed for studying ion—molecule reaction rates. Some techniques measure the microscopic cross-sections or thermal rate coefficients directly, while others measure the phenomenological cross-sections or some apparent rate coefficients relevant to. particular experimental situations. Detailed descriptions and assessments of these techniques are found in refs. 28 and 34. In particular. Chapter 5 of ref. 34 gives critical comparisons of rate data obtained with different techniques and also comparisons with theory. The reader is referred to these excellent reviews. [Pg.304]

Electrical resistivity comes in two different flavours resistivity at initial geometry (subscript IG, p/o), and resistivity including thermal volume expansion (subscript VE, py. The former can be directly determined from the electric signals by rationing the voltage and the current, whereas information about the volume expansion is needed to obtain the latter, by multiplying V/Vq and Physically, electrical resistivity with volume expansion considered is of greater interest because it can be directly compared with data from other measurement techniques, e.g., 4-point measurements. [Pg.313]

The developed bimorph beam model of IPMC was validated using the finite element method (FEM) and the used software was MSC/NASTRAN. As the software does not directly support the electromechanical coupling, the thermal analogy technique as described in [Lim et al. (2005) Taleghani and Campbell (1999)] was used. The simulated versus measured force-displacement relationship of an IPMC actuator is shown in Fig. 2.39. The relative errors for A = 0 between the calculated values and the measured data for 2V and 3V are 2.8% and 3.7%, respectively. The equivalent Young s moduli estimated from the equivalent beam model and the equivalent bimorph beam model are 1.01 GPa and 1.133-1.158 GPa, respectively, which are very close. However, the values from the equivalent beam model... [Pg.45]

Various shear stress measurement techniques have been proposed in the literature. Some of the principal measurement techniques are Stanton tube, Preston tube, electrochemical technique, velocity measurements, thermal method, floating element sensors, sublayer fence, oil-film interferometry and shear stress sensitive liquid crystal. The Stanton tube is a rectangular shaped pitot tube located very close to the boundary wall and the mean velocity measured from this pitot tube pressure difference is directly related to the shear stress. The Preston tube is similar to the concept of the Stanton tube using a pitot static tube close to the surface and the difference between the stagnation pressure at the center of the tube from the static pressure is related to the shear stress. The electrochemical or mass transfer probe is flush mounted with the wall and the concentration at the wall element is maintained constant. The measurement of mass transfer rate between the fluid and the wall element is used for determination of the wall shear stress. One of the limitations of the mass transfer probe is that at very high flow rates, the mass transfer rate becomes large and it may not be possible to maintain the wall concentration constant. A detailed discussion on the above three techniques can be found in Hanratty and Campbell [1]. These shear stress measurement techniques are not ideal MEMS-based techniques. [Pg.1817]


See other pages where Thermal measurement techniques direct is mentioned: [Pg.106]    [Pg.149]    [Pg.345]    [Pg.177]    [Pg.345]    [Pg.223]    [Pg.296]    [Pg.704]    [Pg.2965]    [Pg.2965]    [Pg.3011]    [Pg.408]    [Pg.105]    [Pg.106]    [Pg.162]    [Pg.2]    [Pg.54]    [Pg.164]    [Pg.245]    [Pg.224]    [Pg.1294]    [Pg.70]    [Pg.674]    [Pg.265]    [Pg.354]    [Pg.362]    [Pg.149]    [Pg.35]    [Pg.91]    [Pg.751]    [Pg.643]    [Pg.497]    [Pg.517]    [Pg.276]    [Pg.618]    [Pg.125]    [Pg.111]    [Pg.26]    [Pg.424]    [Pg.105]    [Pg.548]    [Pg.550]    [Pg.629]   
See also in sourсe #XX -- [ Pg.149 , Pg.150 , Pg.151 , Pg.152 ]




SEARCH



Direct measure

Direct measurement

Directly measured

Thermal measurements

Thermal techniques

© 2024 chempedia.info