Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Test ellipsoid

The oriented test ellipsoid T may be chosen to represent an external electromagnetic field, or the main direction of a cavity of an enzyme molecule, or a polarizability ellipsoid of a molecule, or an alignment on the surface of a catalyst, or some other internal or external constraint [199]. [Pg.105]

Figure 4. Segment at the end of the semi-minor axis, b, of an ellipsoid (left), and use of a test plate and auxiliary convex mirror to shorten the optical path of the test (right). Figure 4. Segment at the end of the semi-minor axis, b, of an ellipsoid (left), and use of a test plate and auxiliary convex mirror to shorten the optical path of the test (right).
If one of the stars in the binary is not a neutron star, then the tests become less precise. Suppose that one observes the optical light from the companion to a neutron star. In addition to the spectral information that allows measurement of P and i i, one also has photometric information (e.g., the total optical flux from the companion). The companion is distorted into a pear shape by the gravity of the neutron star, with the point towards the neutron star. Therefore, from the side there is more projected area and hence greater flux than from either end. If the orbit is edge-on (i = 90°) then the flux varies maximally if the orbit is face-on (i = 0°) then there is no variation. Therefore, by modeling the system one can estimate the inclination from the flux variations. This is called the method of ellipsoidal light curves (Avni Bahcall 1975). [Pg.33]

All test accumulators (pressure vessels) were mounted direcdy below the test table. These vessels were mounted vertically with 2 1 ellipsoidal heads on top and bottom. The top head has a well-rounded outlet nozzle sized equal to the SRV inlet to be tested. To test smaller-orifice SRVs, ring-shaped adapter plates having an opening equal to the SRV inlet are used. This arrangement reduces the possibility of starving the flow to the valve. [Pg.232]

Since this failure, most designers have used only ellipsoidal or hemispherical heads that require a minimum temperature, typically 80° F (27° C), for hydrostatic tests of field-erected vessels. [Pg.34]

The essence of the differences between the operation of radial basis function networks and multilayer perceptrons can be seen in Figure 4.1, which shows data from the hypothetical classification example discussed in Chapter 3. Multilayer perceptrons classify data by the use of hyperplanes that divide the data space into discrete areas radial basis functions, on the other hand, cluster the data into a finite number of ellipsoid regions. Classification is then a matter of finding which ellipsoid is closest for a given test data point. [Pg.41]

Deformation of the spherulites in the material between the crazes into a highly stretched, ellipsoidal shape (rig. 13b in a tensile test of a bulk PP specimen this internal deformation condition is found at nominal plastic strains of more than... [Pg.243]

F, is smaller than V, a low /3-value will also result. This illustration by no means implies that fibrinogen must require two equivalent ellipsoids for viscosity and sedimentation. It is not clear why the 3-function for fibrinogen behaves abnormally, if the other weight of evidence is accepted as a correct description of the molecule. It is even possible that the conclusion of Siegel et al. (1953) may eventually turn out to be the correct one. There is need for more extensive tests for the j8-function. [Pg.361]

For ellipsoids of revolution the numerical values of va and vb have been tabulated by Scheraga (1955), and the sum of va and vb (i.e., vr at oj = 0) is identical with the viscosity increment from Simha s equation. Thus Eq. (43) provides an alternative method to that of the non-Newtonian viscosity for the determination of the rotary diffusion coefficient, 0. Cerf has also pointed out that 0 is determinable from the slope at the inflection point (I.P.) of the vr versus w-curve, i.e., w(I.P.) = 2 /30. At present, however, no experimental test of Eq. (43) has as yet been reported. [Pg.374]

In a further generalization of the concept of convexity, the ellipsoid T may be replaced by any other differentiable surface, for example, by a contour surface of another molecule [199], The resulting shape domains can be used for a direct shape comparison and a direct similarity test for these molecules. [Pg.105]

Originally limited to ellipsoids, the use of Mahalonobis distances allows the use of more variables as the confidence ellipsoid can be transformed to a confidence or tolerance hypersphere. These ideas were examined using the microecosystem test method developed by Kersting for the examination of multispecies systems. These three-compartment microecosystems are comprised of an autotrophic, herbivore, and decomposer subsystems that are connected by tubing and pumps. Although relatively simple and small, these systems are operable over a number of years. [Pg.328]


See other pages where Test ellipsoid is mentioned: [Pg.211]    [Pg.211]    [Pg.25]    [Pg.87]    [Pg.119]    [Pg.120]    [Pg.408]    [Pg.146]    [Pg.125]    [Pg.331]    [Pg.678]    [Pg.63]    [Pg.54]    [Pg.345]    [Pg.376]    [Pg.134]    [Pg.398]    [Pg.57]    [Pg.434]    [Pg.245]    [Pg.250]    [Pg.281]    [Pg.274]    [Pg.85]    [Pg.193]    [Pg.179]    [Pg.121]    [Pg.44]    [Pg.340]    [Pg.343]    [Pg.389]    [Pg.156]    [Pg.104]    [Pg.3377]    [Pg.65]    [Pg.397]    [Pg.199]    [Pg.444]   
See also in sourсe #XX -- [ Pg.104 ]




SEARCH



Ellipsoid

Ellipsoidal

© 2024 chempedia.info