Temperature metric units

Table 2.9 Barometer Temperature Correction—Metric Units 2.72... Table 2.9 Barometer Temperature Correction—Metric Units 2.72...
Table A (metric units) gives for these conditions a temperature-altitude factor of. 135.2... Table A (metric units) gives for these conditions a temperature-altitude factor of. 135.2...
Entering Table B (metric units), with a temperature-altitude factor of 135.37 and a barometric reading of 650 mm (corrected for temperature), the correction is found to be. 109.6... [Pg.152]

Entering Table B (metric units), with a temperature-altitude factor of 135.37 and a barometric... [Pg.421]

Properties of Staple Fibers. Fiber diameters range from AAA lo G (Table 2). with the largest production volume in the range C—G. Thermal conductivity of gluss-liber products is influenced by fiber diameter, density or compactness of the liber mass, and temperature conditions. Generally, thermal eunductiv itv ranges between 0.20 and 0.80 (Blu)lin.)f(hr>Ht It F). In metric units. I his is 0.02y and 0.1 15 watl/meter-Kclvin W/ni K. [Pg.618]

C = coefficient of heat conductivity measured in heat units per unit time per unit of packing volume per deg temperature difference usual units are cal per sec per deg C per cc m = a constant for limestone packings, m = 0.0073 for iron ore, 0.0105 anthracite and other coals, 0.0050 blast-furnace charge, 0.0072. The values are in metric units. q = volume of gas flow per unit-time per square unit of cross-sectional packing area, expressed as liters per sec per sq cm T = temperature, deg abs, C = fractional voids (dimensionless) d = diameter of particles, cm... [Pg.220]

The metric unit of volume is the liter (1), which is approximately 1.06 U.S. quarts. The milliliter (ml), equal to 1/1000 1, is usually used as the unit of volume in the measurement of liquids in chemical work. The milliliter is defined as the volume occupied by exactly 1 g of water at 3.98° C (the temperature at which its density is the greatest) and under a pressure of one atmosphere (that is, the normal pressure due to the weight of the air). [Pg.16]

PSYCHROMETRIC CHART HIGH TEMPERATURES SI METRIC UNITS Bwofwtrtc Pvm ur 101.325 liR SEA LEVEL... [Pg.1328]

The PAH solubilities reported in the tables are expressed in both the SI unit mol/L and metric units mg/kg or /xg/kg. The concentration axes for the least-squares fits of the solubility to temperature are labeled as either parts per million (ppm) or parts per billion (ppb). Since the density of water between 4° and 30 °C is essentially constant and equal to 1.000, 1 L of water has a mass of 1 kg. Thus /xg/kg equals ppb and mg/kg equals ppm. [Pg.186]

To be used in connection with Tables 1 and II. either English or metric units, to obtain latitude corrections to temperature-altitude factor. For latitudes 0-45 subtract the correction. For latitudes 45-90 add the correction. [Pg.2611]

In 1960 an international agreement was reached specifying a particular choice of metric units for use in scientific measurements. These preferred units are called SI units, after the French Systeme International d Unites. This system has seven hose units from which all other units are derived (T TAB LE 1.4). In this chapter we will consider the base units for length, mass, and temperature. [Pg.15]

Figure 8.5a shows the plant-wide control structure for both columns. The first two summer blocks add the three-stage temperatures. The multiplier block average multiplies by 0.3333. The last summer block adds the constant 273 to convert the signals back to K from the metric units (°C) used in Aspen Dynamics. The average temperature is 429 K, which is the set point of the TC2 controller shown on the faceplates in Figure 8.5b. Note that the solvent flow controller is on cascade because the solvent flow rate is ratioed to the flow rate of the fresh feed. Figure 8.5a shows the plant-wide control structure for both columns. The first two summer blocks add the three-stage temperatures. The multiplier block average multiplies by 0.3333. The last summer block adds the constant 273 to convert the signals back to K from the metric units (°C) used in Aspen Dynamics. The average temperature is 429 K, which is the set point of the TC2 controller shown on the faceplates in Figure 8.5b. Note that the solvent flow controller is on cascade because the solvent flow rate is ratioed to the flow rate of the fresh feed.
Setting up the multiplier for the reboiler heat input to feed ratio requires the use of metric units flows in kmol/h and heat in GJ/h. Thus, the steady-state value of the second input to the multiplier, which is the temperature-controller output signal, is calculated... [Pg.208]

It is important to remember that Aspen Dynamics uses metric units (heat duties in GJ/h and temperatures in °C), despite the fact that English engineering units are being... [Pg.220]

The heat capacity, or specific heat, is the amount of energy required to raise the temperature of a unit mass of a material one degree. In metric units it is expressed in cal/g°C. It can be measured at constant pressure or constant volume at constant pressure, it is larger than at constant volume because additional energy is required to bring about the volume change against external pressure. The specific heat of amorphous polymers increases with... [Pg.32]


See other pages where Temperature metric units is mentioned: [Pg.489]    [Pg.246]    [Pg.583]    [Pg.11]    [Pg.227]    [Pg.15]    [Pg.325]    [Pg.489]    [Pg.26]    [Pg.412]    [Pg.325]    [Pg.360]    [Pg.270]    [Pg.90]    [Pg.16]    [Pg.65]    [Pg.261]    [Pg.15]    [Pg.156]    [Pg.188]    [Pg.328]    [Pg.479]   