Further chapters cover in detail the characteristics and applications of galvanic anodes and of cathodic protection rectifiers, including specialized instruments for stray current protection and impressed current anodes. The fields of application discussed are buried pipelines storage tanks tank farms telephone, power and gas-pressurized cables ships harbor installations and the internal protection of water tanks and industrial plants. A separate chapter deals with the problems of high-tension effects on pipelines and cables. A study of costs and economic factors concludes the discussion. The appendix contains those tables and mathematical derivations which appeared appropriate for practical purposes and for rounding off the subject. [Pg.583]

Evaporation of LNG from within a containment area on land or from a spill on water 5. Special problems of frozen earth storage tanks for LNG and the effect of flooding... [Pg.432]

The circulatory systems used in association with machine tools are generally conventional in nature, although occasionally their exceptional size creates special problems. The normal installation comprises a storage tank or reservoir, a pump and filter, suitable sprays, jets or other distribution devices, and return piping. The most recent designs tend to eliminate wick feeds and siphon lubrication. [Pg.867]

The V-03 is the equipment number. The type of equipment is a horizontal storage tank. It is used to store methanoi. The capacity is 20,000 gal (76 m3) and the size is 11 ft (3.35 m) in diameter by 31 ft (9.5 m) long. The tank is to be made of carbon steel and will not be insulated. It should be built to withstand a pressure of 10 psig (1.8 kg / cm2). Any vessel with a rating of under 15 psig (2 kg / cm2) is not considered a pressure vessel. No information is given on temperature or corrosion allowances because neither of these factors presents any special problem. The rate of corrosion... [Pg.105]

Developing a layout for buried. storage tanks in an existing chemical plant often po.ses. special problenrs. It may not be possible or practical to move existing underground obstruaioas in the area in whicli the tank must be located. One solution to this problem Is to bury the tank above grade in a concrete contain-... [Pg.365]


See other pages where Storage tanks special problems is mentioned: [Pg.76]    [Pg.1982]    [Pg.2469]    [Pg.126]    [Pg.178]    [Pg.121]    [Pg.174]    [Pg.2450]    [Pg.2230]    [Pg.223]    [Pg.153]    [Pg.24]    [Pg.258]    [Pg.506]    [Pg.208]    [Pg.237]    [Pg.14]    [Pg.4]    [Pg.501]    [Pg.80]    [Pg.295]    [Pg.244]    [Pg.336]    [Pg.459]   