Storage tanks location

Water is pumped from a storage tank located at the base of the unit to one or more spray nozzles that inject a fine water spray into the airstream. In large units, the air movement through the ductwork system ensures efficient mixing of the moisture and the air. Units used in small enclosures or rooms use a fan with the pump on the same shaft. [Pg.720]

Are storage tanks located with ample working space all around ... [Pg.86]

How to contain a leak on a 25-ton bulk chlorine storage tank located at a water reclamation plant. Produced by the City of Albuquerque. Water Environment Federation Purchase 59.99 Isocyanates... [Pg.193]

Taric Qeanq The tank outlet is rarely located in the very bottom of the tank. Indeed, it is about 6 to 12 inches up the side. Why Operate the system for a while, then drain the tank and youTl have the answer The polite name for all of that gunk and muck coating the bottom of the tank is sediment. How did it get there An open tank or a poorly covered one will always allow dirt, leaves, insects, lizards, and mice into the water system. Also, the incoming water may carry its own sediment, held in suspension. In the tranquil waters of the tank, this will precipitate out. Some minerals in the water itself will, upon contact with air, precipitate out in a storage tank. Locating the outlet up the side of the tank a wee bit, then, will always result in this accumulated debris. [Pg.18]

Thermosyphon (Solar) Systems - Thermosyphon systems use a separate storage tank located above the collector. Liquid warmed in the collector rises naturally above the collector, where it is kept until it is needed. The liquid can be either water or a glycol solution. If the fluid is water, freeze protection is provided by electric heat. If the fluid is glycol, the heat from the glycol is transferred to water in the storage tank. [Pg.424]

Third core heat removal system is a passive heat removal system (PHRS). The heat is removed from the monoblock to the water storage tank located around the monoblock vessel. This system ensures the reactor core cooling in case of postulated maximal accident with all secondary equipment failed, reactor protection system failure and total de-energizing of the NPP. [Pg.141]

Since the power station was shutdown, the secondary sodium has been stored cold in storage tanks located under the steam generators. [Pg.203]

Is storage tank location such as to minimize facility damage in a catastrophic event ... [Pg.316]

Water from the main KAFB water system supplies the TA-lll/TA-V water distribution system. The primary water sources are a 1-million gallon storage tank and a 3.5-million gallon storage tank located approximately 5.6 m (3.5 mi) north of TA-lll/TA-V. Water is conveyed from these tanks to TA-lll/TA-V through 0.254-m (10-in) and 0.356-m (14-in) water lines that are cross-connected within these two Technical Areas. In addition, a 700,000-gallon storage tank located east of TA-III provides temporary backup to the TA-lll/TA-V water distribution systems in the event that the supply from the primary water sources is disrupted. [Pg.56]

The definition of hazard earlier in this chapter lists three elements that can lead to accidents activities, conditions and circumstances. Causes of accidents often involve unsafe acts (activities) and unsafe conditions. When performing risk analysis, one may also consider circumstances surrounding a potential event. It is not uncommon for the circumstances to add to the severity of the event. For example, an automobile crashing into another vehicle may deflect into a gasoline storage tank located nearby but not directly involved in an incident. The event just happens to occur at the tank s location. [Pg.26]

Storage tanks subject to the rule may be located an3rwhere along the oil and natural gas production and transmission process. For natural gas, this process extends from the natural gas well to the point where gas enters the distribution system for oil, it extends from the well to the point where oil is transferred to the pipeline for crude oil transmission. Storage tanks located at refineries are not covered by this rule. [Pg.410]

N Basin recirculation facility Contains filtration system used to remove radionuclides from the N Reactor basin water. Reinforced concrete structure. Chemical storage tanks located outside building. [Pg.109]

N EOT Received eaiergency bloudoun of thermally hot primary reactor coolant water 1,300,000-gal storage tank located west of the H Reactor building. [Pg.113]


See other pages where Storage tanks location is mentioned: [Pg.88]    [Pg.292]    [Pg.287]    [Pg.108]    [Pg.88]    [Pg.218]    [Pg.444]    [Pg.865]    [Pg.26]    [Pg.24]    [Pg.378]    [Pg.55]    [Pg.142]    [Pg.143]    [Pg.32]    [Pg.7]    [Pg.9]   
See also in sourсe #XX -- [ Pg.142 , Pg.151 ]