Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Step filter

It remains to be seen, if the approximation using large time steps is reasonable. We shall show later the effect of the approximation on the power spectrum of the trajectory. More specifically, we shall demonstrate that large time steps filter out high frequency motions. [Pg.269]

The explorative analysis of data sets by visual data mining applications takes place in a three-step process During the first step (overview), the user can obtain an overview of the data and maybe can identify some basic relationships between specific data points. In the second step (filtering), dynamic and interactive navigation, selection, and query tools will be used to reorganize and filter the data set. Each interaction by the user will lead to an immediate update of the data scene and will reveal the hidden patterns and relationships. Finally, the patterns or data points can be analyzed in detail with specific detail tools. [Pg.476]

Obviously, the one-step low-pass J filter produces the narrowest profile and is therefore the less efficient in removing direct correlations in HMBC spectra, while the five-step tuned low-pass J filter (f lps) offers the most broadband profile. For this filter, the intensity of the residual /ch signals remains below 0.11% for the range 125 < /ch < 225 Hz, which is remarkable. Interestingly, as long as the /ch couplings range of the molecule remains moderate (—60 Hz), the four- and five-step filters... [Pg.303]

The low-pass J filter efficiency obtained may be improved by implementing a second low-pass J filter element. Taking advantage of the double-difference principle, this two-step filter is expected to yield high... [Pg.311]

The Filtered Backprojection (FBP) method may be used to process by reconstructing the original image from its projections in two steps Filtering and Backprojection. [Pg.176]

In this model, OBPs participate in the selective transport of pheromone and other semiochemicals to their olfactory receptors. The selectivity of the system is likely to be achieved by layers of filters [ 16], i.e., by the participation of compartmentalized OBPs and olfactory receptors. It seems that OBPs transport only a subset of compounds that reach the pore tubules. Some of these compounds may not bind to the receptors compartmentalized in the particular sensilla. The odorant receptors, on the other hand, are activated by a subset of compounds, as indicated by studies in Drosophila, showing that a single OR is activated by multiple compounds [66]. If some potential receptor ligand reaches the pore tubules but are not transported by OBPs, receptor firing is prevented because the receptors are protected by the sensillar lymph. In other words, even if neither OBPs nor odorant receptors (ORs) are extremely specific, the detectors (olfactory system) can show remarkable selectivity if they function in a two-step filter. [Pg.35]

DEFECTS Mask defects Hardware contamination Cleanliness Number of process steps Filtering Gelling... [Pg.165]

Extractables from filter membranes can be classified into two groups, inorganic ions and organic molecules. The organic components are residual components from either the polymerization process or a chemical modification step. Filters are deliberately washed to remove these components, and the extent to which they remain in the membranes is... [Pg.198]

Yo is the inertia of the emulsion and the constants k and y describe the properties of the emulsion but they also depend on the densitometer. Yo in most cases is not known as AP or AY values are usually used, y = tan a and is the contrast of the emulsion. The emulsion can be calibrated with the aid of a step filter which is placed in front of the spectrometer. When the ratio of the intensities passing through two sectors of the filter is given by ... [Pg.63]

Sample preparation parameters should also be studied to establish acceptable ranges for the method. Sample solvent and volume, extraction time, filter type, and volume can be studied and modifications made to determine which are critical. For example, sample solvent composition and volume can be modified to assure that the organic solvent level is not on the edge of failure. Similarly the extraction time can be modified over a range (i.e., 20%) as can fhe settings or type of apparatus (e.g., mechanical shakers, sonic baths) used for this sample preparation step. Filter type and the volume discarded before collection of the final sample solution can be evaluated as part of robustness testing and alternate filter types qualified fo enhance fhe mefhod design space. [Pg.172]

The sector disk in Figure 5-5B can be used for the same purposes as a step filter. The disk is cut to form a series of circular steps so exposure times will vary in a regular manner from one step to another. The step factor is fixed for each disk, but various disks are available. The two most common step sector disks are those in which the angles a, jS, and y change by some fixed multiple, such as a ratio of 1, 2, 4, etc. The other common stepwise change is to make the steps logarithmically related to one another. [Pg.103]

An improvement to the above method is to photograph the spectrum of a sample containing the maximum concentration of the element being considered under conditions that will produce a spectral line of reasonable intensity, but to utilize either a step sector or a step filter in the process. If a standard is obtained by this method, to which the unknown may be compared, it is simple to determine visually if the concentration exceeds or meets specifications. The stepped spectrogram also provides a semiquantitative estimate of how much the concentration is above or below specifications. [Pg.160]

A variation of the two-line method of emulsion calibration is to use a neutral step filter with an accurately known intensity ratio. The percentage transmittances of the light and dense portions of a series of spectral lines covering a range of transmittances from very light to very dense is obtained. From these data a preliminary curve is obtained from which the calibration data can be determined in the same manner as in the two-line method. The lines selected for the two-step method should lie in the same spectral region as the analysis line. [Pg.185]

Emulsion Calibration Data Using a Seven-Step Filter and the Germanium Emission Line at 3039 A... [Pg.189]

For ion detection, several approaches are possible. Classical spark source mass spectrometry has developed the use of photographic plates. Very hard emulsions with low gelatin content are required. Emulsion calibration is similar to that described in optical emission spectrography, but usually varying exposure time are applied instead of using optical step filters. Provided an automated microdensitometer is used, mass spectrography is still a useful tool for survey analysis of solids down to the sub-pg/g level. [Pg.656]

The steady-state optimal Kalman filter can be generalized for time-variant systems or time-invariant systems with non-stationary noise covariance. The time-varying Kalman filter is calculated in two steps, filtering and prediction. For the nonlinear model the state estimate may be relinearized to compensate the inadequacies of the linear model. The resulting filter is referred to the extended Kalman filter. If once a new state estimate is obtained, then a corrected reference state trajectory is determined in the estimation process. In this manner the Filter reduces deviations of the estimated state from the reference state trajectory (Kwon and Wozny, 1999 Vankateswarlu and Avantika, 2001). In the first step the state estimate and its covariance matrix are corrected at time by using new measurement values >[Pg.439]


See other pages where Step filter is mentioned: [Pg.103]    [Pg.311]    [Pg.470]    [Pg.431]    [Pg.280]    [Pg.81]    [Pg.320]    [Pg.101]    [Pg.102]    [Pg.165]    [Pg.183]    [Pg.845]    [Pg.81]    [Pg.650]    [Pg.52]    [Pg.340]    [Pg.85]    [Pg.201]    [Pg.282]   
See also in sourсe #XX -- [ Pg.101 ]




SEARCH



The Step Filter

© 2024 chempedia.info