Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standardization methods routines

The resulting oligonucleotide is often of surprising purity as judged by analytic HPLC or electrophoresis, and up to 30 mg of a deoxyeicosanucleotide (20-base DNA) can be routinely obtained. Nevertheless small amounts of short sequences, resulting from capping and from base-catalysed hydrolysis, must always be removed by quick gel filtration, repeated ethanol precipitation from water (desalting), reverse-phase HPLC, gel electrophoresis, and other standard methods. [Pg.224]

Immunodiffusion and immunoprecipitation, developed ia the 1940s as a means to identify and semiquantitate specific proteias, were the direct precursors to the development ia 1953 of Immunoelectrophoresis, a method used ia many clinical laboratories (5). Single- and double-gel immunodiffusion and immunoelectrophoresis were, ia effect, the first standardized and routinely used immunoassay methods (see Electroseparations, electrophoresis). [Pg.21]

Analytical and Test Methods. Colorimetric quaUtative tests for diketene are known but seldom used (131). Identification is by spectrometric methods. Diketene has typical ir absorption bands at - ISSO, 1855, and 1685 cm , and signals at 3.92 (t), 4.51 (m), and 4.87 (m) ppm in the H-nmr spectmm (CDCl ). Purity is routinely monitored by gc. Alternatively, diketene is quantitatively converted to acetoacetic derivatives which are assayed by standard methods. [Pg.479]

Direct solid sample analysis is still mostly a subsidiary method, confined to specific analytical tasks, rather than truly complementary to traditional analysis via solutions. Solid sampling is not standard in routine... [Pg.626]

The fc0-NAA method has been developed to overcome the labour-intensive and time-consuming work of preparing multi-element standards when routine multielement or panoramic analyses are required [447]. It is intended to be an absolute technique in which uncertain nuclear data are replaced by a composite nuclear constant, the T 0-factor, which has been determined experimentally for each radionuclide with high accuracy. This k0 is given by ... [Pg.663]

If the equilibrium relationships and flow-rates are known (or assumed) the set of material balance equations for each component is linear in the component compositions. Amundson and Pontinen (1958) developed a method in which these equations are solved simultaneously and the results used to provide improved estimates of the temperature and flow profiles. The set of equations can be expressed in matrix form and solved using the standard inversion routines available in modem computer systems. Convergence can usually be achieved after a few iterations. [Pg.545]

The electronic structure method used to provide the energies and gradients of the states is crucial in photochemistry and photophysics. Ab initio electronic structure methods have been used for many years. Treating closed shell systems in their ground state is a problem that, in many cases, can now be solved routinely by chemists using standardized methods and computer packages. In order to obtain quantitative results, electron correlation (also referred to as dynamical correlation) should be included in the model and there are many methods available for doing this based on either variational or perturbation principles [41],... [Pg.290]

At this point, no universal parameter estimation protocol has been adopted, although standard methods have been applied to individual models. The great flexibility that PB-PK models offer in terms of characterizing all types of drug transport makes routine parameter estimation methods unnecessary and unattractive. As with any modeling endeavor, the modeler should have a clear idea of which parameter estimation procedures will be employed so that experiments can be designed properly. [Pg.92]

In the mid-IR, routine infrared spectroscopy nowadays almost exclusively uses Fourier-transform (FT) spectrometers. This principle is a standard method in modem analytical chemistry45. Although some efforts have been made to design ultra-compact FT-IR spectrometers for use under real-world conditions, standard systems are still too bulky for many applications. A new approach is the use of micro-fabrication techniques. As an example for this technology, a miniature single-pass Fourier transform spectrometer integrated on a 10 x 5 cm optical bench has been demonstrated to be feasible. Based upon a classical Michelson interferometer design, all... [Pg.142]

Sets of parameters such as burette volume, reagent strength, increment size and time interval, end-point potential, format of results, etc., can be stored and recalled from memory as standard methods for routine analyses. An alphanumeric keyboard is used to enter or change the parameters, to take individual pX or mV readings and to control the rinsing and the refilling of the automatic burette. Raw titration data and computed analytical results can be printed out as a permanent record, and titration curves can be produced on a chart recorder or VDU. [Pg.538]

Odour measurements were made on routine ex-works sludges collected from sludge holding tanks at three sewage treatment works. Odour potential was measured using the standard method (see 3.1). Investigations carried out were comparisons of -... [Pg.149]

Here I describe a simple numerical method for solving Maxwell s equation in the frequency domain. As the structure to be analysed is onedimensional, Maxwell s equations turn into a system of two coupled ordinary differential equations that can be solved with standard numerical routines. [Pg.141]

Fig. 4 shows an example of simulated CBED pattern using the Bloch wave method described here for Si [111] zone axis and electron accelerating voltage of 100 kV. The simulation includes 160 beams in both ZOLZ and HOLZ. Standard numerical routine was used to diagonalize a complex general matrix (for a list of routines freely available for this purpose, see [23]). The whole computation on a modem PC only takes a few minutes. [Pg.155]

Metabolites of 2-hexanone in biological materials are difficult to determine in routine practice because of the lack of standardized methods for their measurement. As shown in Table 6-1, there are very few well characterized methods for the determination of metabolites of 2-hexanone in biological materials (Nomeir and Abou-Donia 1985 White et al. 1979). The precision, accuracy, reliability, and specificity of existing methods need to be evaluated, and the methods refined and adapted to routine practice. [Pg.70]

The main reason why existing MR CC methods as well as related MR MBPT cannot be considered as standard or routine methods is the fact that both theories suffer from the Intruder state problem or generally from the convergence problems. As is well known, both MR MBPT/CC theories are built on the concept of the effective Hamiltonian that acts in a relatively small model or reference space and provides us with energies of several states at the same time by diagonalization of the effective Hamiltonian. In order to warrant size-extensivity, both theories employ the complete model space formulations. Although conceptually simpler, the use of the complete model space makes the calculations rather... [Pg.76]

Application New methods, required for full vahdation and standardization, first prerequisite for IQC and QA Routinely used (validation and/ or standardization methods), recommended within IQC and QA system... [Pg.781]

In the majority of cases in professional analytical laboratories, a standard method is the starting point for a routine laboratory method, and many of the validation parameters are taken from the published description of the method. The laboratory then must spend some time verifying and validat-... [Pg.234]

In spite of the apparently successful performance of the ebulliometric system in routine use, a number of variables exist in connection with the operation of the system as it has been described. Many of these variables, as many as possible, are overcome by standardization in routine opera tion. However, they must be recognized if the ebulliometric method is to be understood and applied to special problems. [Pg.10]


See other pages where Standardization methods routines is mentioned: [Pg.108]    [Pg.687]    [Pg.116]    [Pg.301]    [Pg.258]    [Pg.32]    [Pg.630]    [Pg.417]    [Pg.866]    [Pg.44]    [Pg.649]    [Pg.342]    [Pg.171]    [Pg.192]    [Pg.616]    [Pg.106]    [Pg.604]    [Pg.233]    [Pg.95]    [Pg.16]    [Pg.223]    [Pg.456]    [Pg.53]    [Pg.130]    [Pg.130]    [Pg.812]    [Pg.441]    [Pg.626]    [Pg.139]   


SEARCH



Method routine

Method standardization

Routine

Standard method

Standardizing method

© 2024 chempedia.info