Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Small Component Balance

The large component accounts for most of the electron density of a spinor, and as such will carry the largest weight in basis set optimizations. It also has the larger amplitude, and as such must weigh heavily in any fitting scheme. This is only natural, and for most purposes, including standard chemical applications, creates no problems. However, there are some properties that depend heavily on the quality of the small component description. One of these would be the interaction of a possible electric dipole moment, dg of the electron with an applied external field, S. This interaction is described by the operator [20] [Pg.281]

Therefore this interaction involves only the small component densities of the wavefunction, and can be expected to be very sensitive to these densities. Another example is the possible electric dipole moment of a nucleon. Quiney et al. [21] have shown that the calculation of this interaction depends crucially on the ratio between the large and small component in the nuclear region. For the case of TIF, even large energy-optimized basis sets proved to be unsuitable and had to be replaced by large even-tempered [Pg.281]


The presence of the momentum operator means that the small component basis set must contain functions which are derivatives of the large basis set. The use of kinetic balance ensures that the relativistie solution smoothly reduees to the non-relativistic wave function as c is increased. [Pg.214]

A differential balance written for a vanishingly small control volume, within which t A is approximately constant, is needed to analyze a piston flow reactor. See Figure 1.4. The differential volume element has volume AV, cross-sectional area A and length Az. The general component balance now gives... [Pg.19]

Considering the end regions of the column as well-mixed stages, with small but finite rates of mass transfer, component balance equations can be derived for end stage 0... [Pg.195]

The radial functions Pmi r) and Qn ir) may be obtained by numerical integration [16,17] or by expansion in a basis (for recent reviews see [18,19]). Since the Dirac Hamiltonian is not bound from below, failure to observe correct boundary conditions leads to variational collapse [20,21], where admixture of negative-energy solutions may yield energies much below experimental. To avoid this failure, the basis sets used for expanding the large and small components must maintain kinetic balance [22,23]. [Pg.163]

An application of the variational principle to an unbounded from below Dirac-Coulomb eigenvalue problem, requires imposing upon the trial function certain conditions. Among these the most important are the symmetry properties, the asymptotic behaviour and the relations between the large and the small components of the wavefunction related to the so called kinetic balance [1,2,3]. In practical calculations an exact fulfilment of these conditions may be difficult or even impossible. Therefore a number of minimax principles [4-7] have been formulated in order to allow for some less restricted choice of the trial functions. There exist in the literature many either purely intuitive or derived from computational experience, rules which are commonly used as a guidance in generating basis sets for variational relativistic calculations. [Pg.177]

In the case of digoxin we can visualize what is happening. The site of action and binding site of digoxin is to tissue Na+K+ATPase. This enzyme is distributed very widely in tissues, and particularly in excitable tissue, which depends on it to restore sodium/potassium balance to resting levels after excitation. Digoxin preferentially distributes therefore to these tissues, and a disproportionately small component is left in the plasma compartment from which we sample. [Pg.135]

Errors in the MESH equations of Sec. 4.1.2 should be small, including the stage energy total material and component balances and summation equation should be small. The physical solution criteria above should take precedence over any mathematical criteria, such as having Newton-Raphson functions approach zero (Sec. 4.2.6). [Pg.149]

Euler s equation will suffice as long as the time step, At, is kept small. Jelinek et al. (61) and Mori et al. (62) developed techniques for calculating the time step and the composition derivative and restated the component balance equations accordingly. [Pg.180]

The governing equation for mass transfer that should be solved to find values of follows from the component balance over a small element of the fluid domain. For steady-state, fully developed, incompressible flow in the z-direction, the component balance results in... [Pg.371]

Consequently, an equation describing the concentration in the catalyst domain is also needed. This equation follows from a component balance over a small element of the catalyst domain for steady state it yields... [Pg.371]

The presence of the momentum operator means that the small component basis set must contain functions which are derivatives of the large basis set. The use of kinetic balance ensures that the relativistic solution smoothly reduces to the non-relativistic wave function as c is increased.--------------------------------------------------------------------... [Pg.214]


See other pages where Small Component Balance is mentioned: [Pg.281]    [Pg.281]    [Pg.273]    [Pg.214]    [Pg.130]    [Pg.22]    [Pg.323]    [Pg.171]    [Pg.369]    [Pg.376]    [Pg.377]    [Pg.377]    [Pg.400]    [Pg.445]    [Pg.133]    [Pg.164]    [Pg.167]    [Pg.133]    [Pg.164]    [Pg.167]    [Pg.317]    [Pg.317]    [Pg.320]    [Pg.337]    [Pg.273]    [Pg.130]    [Pg.45]    [Pg.41]    [Pg.160]    [Pg.52]    [Pg.220]    [Pg.255]    [Pg.115]    [Pg.214]    [Pg.126]    [Pg.1817]   


SEARCH



Component balances

© 2024 chempedia.info