Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Skew determinant

When two constituents of a determinant hold the same relative position with respect to the leading constituents, they are said to be conjugate, Thus in the last of the determinants in (34) bx and q are conjugate, so are b3 and c2, r and cv If the conjugate elements are equal) the determinant is symmetrical, if equal but opposite in sign, we have a skew determinant. The square of a determinant is a symmetrical determinant. [Pg.590]

Reaction of iron atoms with cycloheptatriene to form [Fe( r) -C7H7)-(t7 -C7H9)] was confirmed by another group 15) these workers determined the crystal structure of the species, demonstrating a sandwich structure with the open faces of the two 7j -systems skewed to each other. The temperature-dependent NMR spectrum of this species (16) indicated two types of fiuxional behavior in solution. Evidence for a 1,-2-shift mechanism of the l-5-i7-cycloheptatrienyl moiety in the structure shown. [Pg.156]

The raw data in the more comprehensive study (61) were conversions, determined in duplicate, when each of 104 coals selected from three geological provinces was heated with tetralin under standard conditions, together with the results of 14 commonly made analytical determinations for each coal. An early observation in this study was that when data for all 104 samples were plotted against volatile matter, a steady decrease of conversion with decreasing volatile matter was apparent. But there was a great deal of scatter (r=0.85). In any case, the formal requirements that make possible the employment of valid statistical analyses were not met by the data matrix, as evidenced by skewed and bimodal relationships between the variables the sample set was heterogeneous. ... [Pg.22]

The time-domain IRF can be comparatively broad and skewed functions. The IRF needs to be taken into account in the data acquisition procedure and analyses to minimize systematic errors in the lifetime determination, in particular if the lifetimes are short. [Pg.130]

Single-valued potential, adiabatic-to-diabatic transformation matrix, non-adiabatic coupling, 49-50 topological matrix, 50-53 Skew symmetric matrix, electronic states adiabatic representation, 290-291 adiabatic-to-diabatic transformation, two-state system, 302-309 Slater determinants ... [Pg.98]

For EMG peaks, peak skew increases with the ratio xG/oG. Figure 16-32 illustrates the characteristics of such a peak calculated for xG/aG = 1.5. In general, with xG/aG > 1 (peak skew > 0.7), a direct calculation of the moments is required to obtain a good approximation of the true value of N , since other methods give a large error (Yau et al., Modems Size-Exclusion Liquid Chromatography, Wiley, New York, 1979). Alternatively, Eq. (16-165) can be fitted to experimental peaks to determine the optimum values of fG, aG, and xG. [Pg.41]

This technique allows us to separate the total product spectrum into an al and an a2 contribution. This also highlights the point that for this technique to give accurate results, the product spectrum needs to be determined very accurately, especially in the region that is used to calculate a2. Small variations in the products measured will skew the a2 determination and result in the inaccurate product separation. This only highlights the fact that care should be taken with... [Pg.189]

To determine whether the skew was responsible for the taxonic findings, Gleaves et al. transformed the data using a square root or log transformation and were successful at reducing the skew of all but one indicator to less than 1.0. This is a fairly conservative test of the taxonic Conjecture, because data transformation not only reduces indicator skew, but it can also reduce indicator validities, and hence produce a nontaxonic result. Yet, this did not happen in this study. All but one plot originally rated as taxonic were still rated as taxonic after the transformation. MAMBAC base rate estimates were. 19 (SD =. 18) for transformed empirical indicators, and. 24 (SD =. 06) for transformed theoretical indicators. Nevertheless, these estimates are probably not as reliable as the original estimates because of the possible reduction in validity, which is likely to lower the precision of the estimates. [Pg.144]

Thus the two parameters of the distribution can be determined after finding the variance and skewness from the experimental RTD. [Pg.547]

Both methods are also limited in accuracy of secondary structure determinations because spectral peaks must be deconvolved estimates are made of the overlapping contributions of different structural regions. These estimates may introduce error based on the reference spectra used and because deconvolution methods equate crystallographic secondary structure with the secondary structure of the protein in solution (Pelton and McLean, 2000). As amyloid fibrils are neither crystalline nor soluble, there may be even greater error in estimates of secondary structure. To compound the problem, estimates of /f-sheet content are less reliable than those of a-helix, because of the flexibility and variable twist of / -structure (Pelton and McLean, 2000). In addition, / -sheet and turn bands overlap in FTIR spectroscopy (Jackson and Mantsch, 1995 Pelton and McLean, 2000). Side chains also contribute to spectral peaks in both methods, and they can skew estimates of secondary structure if not properly accounted for. In FTIR spectra, up to 10-15% of the amide I band may arise from side chain contributions (Jackson and Mantsch, 1995). [Pg.269]

The distribution of Lp(a) concentrations in white populations is highly skewed, but does not differ significantly between males and females (Fig. 7). The median Lp(a) value determined in a Belgian population sample is 0.140 g/liter (L3), in agreement with values reported in other European and Caucasian American populations (H26). [Pg.81]

FIGURE 47. Three-dimensional structure of the cyclohexene ring of retinal in bR as determined by 2H NMR, relative to the membrane surface in the x-y plane. Analysis of the orientations of the three deuterium labeled methyl groups on the puckered ring (skew around C1-C6) indicates that the chromophore has a 6s-trans conformation around the C6-C7 bond. Reprinted with permission from Reference 60. Copyright (1997) American Chemical Society... [Pg.163]


See other pages where Skew determinant is mentioned: [Pg.216]    [Pg.327]    [Pg.216]    [Pg.327]    [Pg.546]    [Pg.548]    [Pg.1533]    [Pg.111]    [Pg.604]    [Pg.17]    [Pg.855]    [Pg.404]    [Pg.29]    [Pg.274]    [Pg.1355]    [Pg.29]    [Pg.41]    [Pg.69]    [Pg.741]    [Pg.279]    [Pg.24]    [Pg.20]    [Pg.21]    [Pg.309]    [Pg.267]    [Pg.244]    [Pg.181]    [Pg.85]    [Pg.925]    [Pg.332]    [Pg.348]    [Pg.269]    [Pg.142]    [Pg.249]    [Pg.900]    [Pg.147]    [Pg.133]   
See also in sourсe #XX -- [ Pg.590 ]




SEARCH



Skewed

Skewing

Skewness

© 2024 chempedia.info