Single-capacitors switching

R and are voltage damping impedances Figure 23.4 A single capacitor switching... [Pg.729]

Thus, for a single capacitor switching of a 60 kVAr bank, a rating of 125 A will be required for the switch, fuse and the contactor etc. [Pg.756]

Fig. 1 Diagram of a single photodiode-capacitor switch (top) and an electronic schematic of the linear array (bottom). Fig. 1 Diagram of a single photodiode-capacitor switch (top) and an electronic schematic of the linear array (bottom).
When a single uncharged capacitor unit is switched on a power circuit, as illustrated in Figure 23.20, then... [Pg.751]

Here we have considered the fault level of the switching circuit to be same as that of the entire system, as they are the total capacitor banks connected in the system and switched together as a single unit. [Pg.752]

Single phase motors do exhibit operational problems in pony motor applications. The capacitors in these motors store energy and the motors resist external attempts to rotate them. Single phase motors can be made to work on pony motor applications by splicing into the capacitor circuit and connecting it in series with an open auxiliary switch in the active motor starter. [Pg.83]

Single-Phase Operation. If single-phase power only is available, it is advisable to consider the use of single-phase to three-phase converters and three-phase motors. This avoids the use of large single-phase capacitor start motors, which are relatively expensive and contain a starting switch that could be a source of trouble due to failure or to the presence of flammable gas in the vicinity of the well,... [Pg.415]

But if you have two or more switching channels being used to generate a single output rail, that is truly an interleaved supply, and most of the arguments in favor of interleaving for input capacitor reduction do apply. [Pg.295]

For small U and C values, the discharge resistor may be permanently connected to the capacitor. In the example given above, the resulting power loss would be 10 kW. Consequently, a discharge switch shall be fitted which automatically closes the discharge circuit. For pressurized apparatus, a single-pole vacuum tube (contactor type) may be used. Its open position is achieved by a pneumatically actuated drive, the closed position should be maintained by the atmospheric air pressure, and, if necessary, by an additional helical spring. [Pg.127]


See other pages where Single-capacitors switching is mentioned: [Pg.731]    [Pg.751]    [Pg.751]    [Pg.759]    [Pg.774]    [Pg.731]    [Pg.751]    [Pg.751]    [Pg.759]    [Pg.774]    [Pg.753]    [Pg.640]    [Pg.296]    [Pg.460]    [Pg.124]    [Pg.754]    [Pg.576]    [Pg.241]    [Pg.24]    [Pg.73]    [Pg.143]    [Pg.268]    [Pg.36]    [Pg.460]    [Pg.176]    [Pg.36]    [Pg.37]    [Pg.519]    [Pg.1195]    [Pg.10]    [Pg.58]    [Pg.128]    [Pg.253]    [Pg.81]    [Pg.576]    [Pg.166]    [Pg.10]    [Pg.58]    [Pg.128]    [Pg.193]   