Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Setting requirements

In some eases there no set requirements for a site safety and health offieer (SSHO). Under the DOE there are usually speeifie requirements outlined in the seope of work. However, assigning an SSHO who does... [Pg.33]

The process itself often sets requirements on the ventilation parameters, and it also affects the ventilation—for example, by secondary flows coming from moving wires or trucks. A very special case is clean rooms, where the high purity requirements set strict target conditions for ventilation. [Pg.406]

The so-called standard instrument is used for interpolation between the fixed points and for the calibration of other thermometers lower in the metrological hierarchy. The standard instrument in the moderate temperature range is a special platinum resistance probe, as it has to fulfill set requirements. It is important in all calibration that traceability to a primary normal, here the fixed-point ITS-90 scale, exists. [Pg.1140]

Working procedures Set requirements on how an industrial work process is carried out. [Pg.1489]

The experimental bond length for the hydrogen fluoride molecule is 0.917A. Determine the basis set required to predict this structure accurately. Perform your optimizations at the MP4 level of theory (electron correlation is known to be important for this system). [Pg.103]

In practice a DFT calculation involves an effort similar to that required for an HF calculation. Furthermore, DFT methods are one-dimensional just as HF methods are increasing the size of the basis set allows a better and better description of the KS orbitals. Since the DFT energy depends directly on the electron density, it is expected that it has basis set requirements similar to those for HF methods, i.e. close to converged with a TZ(2df) type basis. [Pg.192]

The basis set requirements for obtaining a certain accuracy of a given molecular property are usually different from those required for a corresponding accuracy in... [Pg.261]

This reaction has been regarded by previous authors as the prototype of o reactions (2, 28). It also figured heavily in the definition of the a" parameters of Wepster for —R para substituents (2e). However, we find that the data set for this reaction series is not fitted with acceptable precision by eq. (1) and data fitted even as well by other parameters (for Oi (BA)> SD=. 43, f=. 329 for S L parameters, SD=. 38, /=. 287). Thus, the data for this set appear truly exceptional. The largest deviations for individual substituents in the fitting with cr (A) parameters are found among both -R (NMe2, NH2, F) and +R (NO2 and MeCO) substituents. Because the data sets for both m- and p- substituents meet the minimal basis set requirements, we have utilized these in a manner similar to that described for the definition of Ur(a) parameters to obtain a comparative set of parameters. [Pg.50]

It was desirable to test for possible inadequacy of the Oj values for certain substituents. This testing has been done with data for several reaction rate and equilibrium series for which both the p- and m- sets meet the minimal basis set requirements. The p and p/ values for the m- and p- positions obtained in preliminary fittings were held as constraints in the data, with the result that both Oj and Or values were generated from best fitting. [Pg.53]

Whereas ISO Guide 34 sets requirements for the quality system of a GRM producer, ISO Guide 35 (1989) provides guidance on how to implement many of these requirements. Among these, the document also provides a general and statistical outline of the process that leads to CRMs. The current edition of ISO Guide 35 is a little outdated, but stiU most of the contents are valid. [Pg.10]

A project for the future could be the comparison of the data sets required by authorities of countries such as the USA or Japan. Moreover, discussions can be... [Pg.36]

One should therefore expect that the basis set requirements in Kohn-Sham calculations are less severe than in wave function based ones. Indeed, in most applications this is the case (see, e. g., Bauschlicher et al., 1997, and Martin, 2000). [Pg.113]

Overall, the accuracy reached by the hybrid functionals tested is quite pleasing, in particular if we keep in mind the favorable scaling of computational demands and the obviously much lower basis set requirements. The binding energy of the water molecule computed with the B3LYP and the mPWIPW functional miss the lower experimental error bar by only 0.1 kcal/mol and approach quite closely the best available conventional wave function based data. [Pg.242]

This chapter is not simply a treatise on the highest capacity methods for measuring aqueous solubility in a discovery setting that most closely approximate a lower capacity thermodynamic solubility measurement. Rather it is the author s viewpoint that dealing with the problem of poor drug solubility in an early discovery setting requires an appreciation of recent changes in three related but distinct areas. The areas to be considered are ... [Pg.215]

Good, or best, compression set requires a post cure, although at least one manufacturer has introduced a new series of polyacrylates that only require a press cure. [Pg.103]

The computerized systems, both hardware and software, that form part of the GLP study should comply with the requirements of the principles of GLP. This relates to the development, validation, operation and maintenance of the system. Validation means that tests have been carried out to demonstrate that the system is fit for its intended purpose. Like any other validation, this will be the use of objective evidence to confirm that the pre-set requirements for the system have been met. There will be a number of different types of computer system, ranging from personal computers and programmable analytical instruments to a laboratory information management system (LIMS). The extent of validation depends on the impact the system has on product quality, safety and record integrity. A risk-based approach can be used to assess the extent of validation required, focusing effort on critical areas. A computerized analytical system in a QC laboratory requires full validation (equipment qualification) with clear boundaries set on its range of operation because this has a high... [Pg.222]

The example given above shows that CIS can simulate the effect of the complete passive defence chain in a consistent way. The strength of CIS is that it can simulate this effect for a huge number of different situations and thus is able to establish passive defence requirements in a systematic way. The proof of principle for simulating the complete protection chain has been given. Extensive work has to be done to refine this approach, so that CIS can be an effective tool to set requirements for real life situations. [Pg.70]

The base set required for all excipients is detailed in Table 13.11. These are sufficient, however, only for those excipients intended for use for up to two weeks in humans. [Pg.491]


See other pages where Setting requirements is mentioned: [Pg.122]    [Pg.80]    [Pg.232]    [Pg.546]    [Pg.282]    [Pg.388]    [Pg.120]    [Pg.219]    [Pg.214]    [Pg.367]    [Pg.21]    [Pg.18]    [Pg.688]    [Pg.554]    [Pg.220]    [Pg.57]    [Pg.544]    [Pg.113]    [Pg.159]    [Pg.181]    [Pg.205]    [Pg.220]    [Pg.225]    [Pg.233]    [Pg.54]    [Pg.158]    [Pg.108]    [Pg.457]    [Pg.382]   
See also in sourсe #XX -- [ Pg.105 ]




SEARCH



© 2024 chempedia.info