Emergency stop devices are required for machinery They shall have a red button on yellow background, be self-latching, positively opening, readily accessible to operator, manually activated, require manual reset. Resetting the E-stop switch shall not restart any part of the machine. [Pg.117]

The bellows of collapsible containers overlap and fold to retain their folded condition without external assistance, thus providing a self-latching feature. This latching is the result of bringing together under pressure two adjacent conical sections of unequal proportions and different angulations to the bottle axis. On a more technical analytical... [Pg.318]

System operation is started by momentarily depressing switch 51. This applies power to the coil of relay K, thus closing K contacts. Relay K is now electrically self-latched. The closure of relay K contacts allows power to be applied to the coil of relay K2, whose contacts close to start up the pump motor. [Pg.215]

Crane hooks used to lift personnel baskets will have a positive locking device equipped with a locking pin. Spring-loaded latches and self-latching mechanisms must also be closed and secured with a locking pin. [Pg.326]

Metal-organic nanocomposite materials are interesting from the point of view of the bottom-up approach to building future electronic devices. The ability of the organic parts of the composite materials to identify and latch on to other organic molecules is the basis for the possible self assembly of nanoscale devices, while the metallic components provide mechanical robustness and improve the electrical conductance. [Pg.307]

Note that it is not necessary to use a latching or self-holding relay. A single impulse to the relay s activating coil will cause disruption... [Pg.314]

NFPA 30,5.5.2.1 4.4.21 If hose is used in the transfer operation, it shall be equipped with a self-closing valve without a hold-open latch in addition to the outlet valve. Only listed or approved hose shall be used. [Pg.216]

Some early oven doors were of the guillotine type, which could be raised or lowered vertically with a simple hoist. These were replaced when machinery was developed to install and remove doors horizontally with the door in a vertical position. All the early doors were sealed with a clay-water mixture known as luting material. Most oven doors are self-sealing a thin metal strip on the door is pressed against the metal doorjamb by screw or spring pressure exerted against door latches. [Pg.511]

In Japan, the self-actuated shutdown system (SASS) has been developed as a passive safety feature (Takamatsu et al. 2007 Nakanishi et al. 2008) using the phenomena that electromagnetic force of the control rod latch will be lost when alloy temperature exceeds the Curie point. Several kinds of in-sodium transient testing have been carried out together with in-pile experiments in the experimental fast reactor Joyo. This mechanism is effective to the robust restraint core, which is designed for seisnuc requirements. [Pg.2693]

Hooks with self-closing latches or their equivalent must be used. Exception J hooks are permitted to be used for setting wooden taisses. [Pg.1262]

At 1910.106(d)(3)(ii), OSHA prescribes the requirements for storage cabinets, whether made of metal or wood. The regulation does not make any mention of self-closing doors nor does the NFPA standard on flammable liquids. However, the International Fire Code (3404.3.2.1.3, Doors ) says of flammable storage cabinets that Doors shall be well fitted, self closing an6 equipped with a three-point latch. ... [Pg.137]

Many vendors now sell gas cabinets equipped with self-closing and latching doors and windows, sprinkler heads and various types of purge assemblies (see Fig. 5). Cabinets should be provided with a minimum flow of 100 feet per minute through the louver on the cabinet bottom. When the window is opened, the face velocity through the window should be maintained at 100 fpm. Purge assembhes may contain many different types of safety devices. An emergency shutoff valve should be located as close to the cylinder as is practicable. An air operated remotely activated cylinder valve is more preferable. System shutoff may be by manual activation of a remote switch in the laboratory or fabrication area or caused by other system defaults interlocked to gas flow. System defaults may include ... [Pg.354]

Self-closing All fire doors should be fitted with self-closing devices that are maintained so that the door closes positively against the door stops and where appropriate latches effectively. The notable exceptions to this are those doors that are normally kept locked shut, e.g. doors to cupboards or service ducts.Where it is considered a hindrance to have a fire door closed at all times it may be held open by an automatic release mechanism that is actuated by an automatic detection and alarm system. [Pg.183]


See other pages where Self-latching is mentioned: [Pg.384]    [Pg.149]    [Pg.59]    [Pg.195]    [Pg.502]    [Pg.506]    [Pg.207]    [Pg.384]    [Pg.149]    [Pg.59]    [Pg.195]    [Pg.502]    [Pg.506]    [Pg.207]    [Pg.333]    [Pg.90]    [Pg.65]    [Pg.458]    [Pg.134]    [Pg.306]    [Pg.306]    [Pg.1162]    [Pg.162]    [Pg.8]    [Pg.124]    [Pg.458]    [Pg.67]    [Pg.228]    [Pg.30]    [Pg.658]    [Pg.394]    [Pg.151]    [Pg.504]    [Pg.25]    [Pg.620]    [Pg.246]    [Pg.103]    [Pg.67]    [Pg.108]   