Scanning transmission STEM

Electron microscopy (EM), in particular in modern scanning transmission (STEM) instruments, has analytical resolution down to 1 nm, but within that lateral resolution, local bulk rather than surface analysis is provided. The semi-quantitative analytical capabilities are impressive 10 14 g (small spot ESCA or SIMS), or 5 x 10 20 g (analytical STEM) of matter. [Pg.20]

The very high powers of magnification afforded by the electron microscope, either scanning electron microscopy (sem) or scanning transmission electron microscopy (stem), are used for identification of items such as wood species, in technological studies of ancient metals or ceramics, and especially in the study of deterioration processes taking place in various types of art objects. [Pg.417]

Figure 1 Signals generated when the focussed electron beam interacts with a thin specimen in a scanning transmission electron microscope (STEM). Figure 1 Signals generated when the focussed electron beam interacts with a thin specimen in a scanning transmission electron microscope (STEM).
Analysis of individual catalyst particles less than IMm in size requires an analytical tool that focuses electrons to a small probe on the specimen. Analytical electron microscopy is usually performed with either a dedicated scanning transmission electron microscope (STEM) or a conventional transmission electron microscope (TEM) with a STEM attachment. These instruments produce 1 to 50nm diameter electron probes that can be scanned across a thin specimen to form an image or stopped on an image feature to perform an analysis. In most cases, an electron beam current of about 1 nanoampere is required to produce an analytical signal in a reasonable time. [Pg.362]

The scanning transmission electron microscope (STEM) was used to directly observe nm size crystallites of supported platinum, palladium and first row transition metals. The objective of these studies was to determine the uniformity of size and mass of these crystallites and when feasible structural features. STEM analysis and temperature programmed desorption (TPD) of hydrogen Indicate that the 2 nm platinum crystallites supported on alumina are uniform In size and mass while platinum crystallites 3 to 4 nm in size vary by a factor of three-fold In mass. Analysis by STEM of platinum-palladium dn alumina established the segregation of platinum and palladium for the majority of crystallites analyzed even after exposure to elevated temperatures. Direct observation of nickel, cobalt, or iron crystallites on alumina was very difficult, however, the use of direct elemental analysis of 4-6 nm areas and real time Imaging capabilities of up to 20 Mx enabled direct analyses of these transition metals to be made. Additional analyses by TPD of hydrogen and photoacoustic spectroscopy (PAS) were made to support the STEM observations. [Pg.374]

Figure 5 shows the Z-contrast scanning transmission electron microscope (STEM) image of a Ru/Sn02 nanocomposite catalyst prepared by the assembly process [18]. A combined EDX analysis, using an electron beam of... [Pg.334]


See other pages where Scanning transmission STEM is mentioned: [Pg.12]    [Pg.121]    [Pg.12]    [Pg.121]    [Pg.1623]    [Pg.269]    [Pg.269]    [Pg.270]    [Pg.86]    [Pg.223]    [Pg.14]    [Pg.14]    [Pg.117]    [Pg.117]    [Pg.135]    [Pg.161]    [Pg.50]    [Pg.197]    [Pg.206]    [Pg.222]    [Pg.416]    [Pg.358]    [Pg.544]    [Pg.329]    [Pg.331]    [Pg.375]    [Pg.163]    [Pg.288]    [Pg.312]    [Pg.349]    [Pg.7]    [Pg.173]    [Pg.760]    [Pg.127]    [Pg.151]    [Pg.227]    [Pg.449]    [Pg.199]   
See also in sourсe #XX -- [ Pg.101 ]

See also in sourсe #XX -- [ Pg.28 , Pg.43 , Pg.85 , Pg.486 ]